This Annex provides the method to determine the levels of evaporative emission from light-duty vehicles in a repeatable and reproducible manner designed to be representative of real world vehicle operation.
The general requirements for conducting the type 4 test shall be those set out in paragraph 6.6. of UN Regulation No 154. The limit value shall be that specified in Table 3 of Annex I to Regulation (EC) No 715/2007.
The technical requirements for conducting the type 4 test shall be those set out in Annex C3 to UN Regulation No 154.
BWC | Butane working capacity
PF | Permeability factor
APF | Assigned permeability factor
OVC-HEV | Off-vehicle charging hybrid electric vehicle
NOVC-HEV | Not off-vehicle charging hybrid electric vehicle
WLTC | Worldwide light-duty test cycle
REESS | Rechargeable electric energy storage system
5.1.
The vehicle and its components liable to affect the evaporative emissions shall be designed, constructed and assembled so as to enable the vehicle in normal use and under normal conditions of use such as humidity, rain, snow, heat, cold, sand, dirt, vibrations, wear, etc. to comply with the provisions of this Regulation during its useful life.
5.1.1.
This shall include the security of all hoses, joints and connections used within the evaporative emission control systems.
5.1.2.
For vehicles with a sealed fuel tank system, this shall also include having a system which, just before refuelling, releases the tank pressure exclusively through a vapour storage unit which has the sole function of storing fuel vapour. This ventilation route shall also be the only one used when the tank pressure exceeds its safe working pressure.
5.2.
The test vehicle shall be selected in accordance with paragraph 5.5.2.
5.3.1.
The types and amounts of lubricants and coolant for emissions testing shall be as specified for normal vehicle operation by the manufacturer.
5.3.2.
The type of fuel for testing shall be as specified in Section A.1 of Annex IX.
5.3.3.
All evaporative emissions controlling systems shall be in working order.
5.3.4.
The use of any defeat device is prohibited in accordance with the provisions of Article 5(2) of Regulation (EC) No 715/2007.
5.4.1.
The provisions for electronic system security shall be those specified in paragraph 2.3. of Annex I.
5.5.1.
Only vehicles that are identical with respect to the characteristics listed in (a), (c) and (d), technically equivalent with respect to the characteristics listed in (b) and similar or, where applicable, within the stated tolerance regarding the characteristics listed in (e) and (f) may be part of the same evaporative emission family:
Fuel tank system material and construction;
Vapour hose material, fuel line material and connection technique;
Sealed tank or non-sealed tank system;
Fuel tank relief valve setting (air ingestion and relief);
Canister butane working capacity (BWC300) within a 10 per cent range of the highest value (for canisters with the same type of charcoal, the volume of charcoal shall be within 10 per cent of that for which the BWC300 was determined);
Purge control system (for example, type of valve, purge control strategy).
5.5.2.
The vehicle shall be considered to produce worst-case evaporative emissions and shall be used for testing if it has the largest ratio of fuel tank capacity to canister butane working capacity within the family. The vehicle selection shall be agreed in advance with the approval authority.
5.5.3.
The use of any innovative system calibration, configuration, or hardware related to the evaporative control system shall place the vehicle model in a different family.
Each of the evaporative emission families defined in paragraph 5.5.1. shall be attributed a unique identifier of the following format:
EV-nnnnnnnnnnnnnnn-WMI-x
Where:
nnnnnnnnnnnnnnn is a string with a maximum of fifteen characters, restricted to using the characters 0-9, A-Z and the underscore character ‘_’.
WMI (world manufacturer identifier) is a code that identifies the manufacturer in a unique manner defined in ISO 3780:2009.
x shall be set to ‘1’ or ‘0’ in accordance with the following provisions:
With the agreement of the approval authority and the owner of the WMI, the number shall be set to ‘1’ where a vehicle family is defined for the purpose of covering vehicles of:
a single manufacturer with one single WMI code;
a manufacturer with several WMI codes, but only in cases when one WMI code is to be used;
more than one manufacturer, but only in cases when one WMI code is to be used.
In the cases (i), (ii) and (iii), the family identifier code shall consist of one unique string of n-characters and one unique WMI code followed by ‘1’.
With the agreement of the approval authority, the number shall be set to ‘0’ in the case that a vehicle family is defined based on the same criteria as the corresponding vehicle family defined in accordance with point (a), but the manufacturer chooses to use a different WMI. In this case the family identifier code shall consist of the same string of n-characters as the one determined for the vehicle family defined in accordance with point (a) and a unique WMI code which shall be different from any of the WMI codes used under case (a), followed by ‘0’.
5.6.
The approval authority shall not grant type approval if the information provided is insufficient to demonstrate that the evaporative emissions are effectively limited during the normal use of the vehicle.
The limit value shall be that specified in Table 3 of Annex I to Regulation (EC) No 715/2007.