This appendix describes the procedure to determine the instantaneous mass and particle number emissions [g/s; #/s], following application of the data consistency rules of Appendix 4. The instantaneous mass and particle number emissions shall then be used for the subsequent evaluation of a RDE trip and the calculation of the intermediate and final emission result as described in Appendix 11.
α | — | molar hydrogen ratio (H/C)
β | — | molar carbon ratio (C/C)
γ | — | molar sulphur ratio (S/C)
δ | — | molar nitrogen ratio (N/C)
Δtt,i | — | transformation time t of the analyser [s]
Δtt,m | — | transformation time t of the exhaust mass flow meter [s]
ε | — | molar oxygen ratio (O/C)
ρe | — | density of the exhaust
ρgas | — | density of the exhaust component ‘gas’
λ | — | excess air ratio
λi | — | instantaneous excess air ratio
A/Fst | — | stoichiometric air-to-fuel ratio [kg/kg]
cCH4 | — | concentration of methane
cCO | — | dry CO concentration [%]
cCO2 | — | dry CO2 concentration [%]
cdry | — | dry concentration of a pollutant in ppm or per cent volume
cgas,i | — | instantaneous concentration of the exhaust component ‘gas’ [ppm]
cHCw | — | wet HC concentration [ppm]
cHC(w/NMC) | — | HC concentration with CH4 or C2H6 flowing through the NMC [ppmC1]
cHC(w/oNMC) | — | HC concentration with CH4 or C2H6 bypassing the NMC [ppmC1]
ci,c | — | time-corrected concentration of component i [ppm]
ci,r | — | concentration of component i [ppm] in the exhaust
cNMHC | — | concentration of non-methane hydrocarbons
cwet | — | wet concentration of a pollutant in ppm or per cent volume
EE | — | ethane efficiency
EM | — | methane efficiency
Ha | — | intake air humidity [g water per kg dry air]
i | — | number of the measurement
mgas,i | — | mass of the exhaust component ‘gas’ [g/s]
qmaw,i | — | instantaneous intake air mass flow rate [kg/s]
qm,c | — | time-corrected exhaust mass flow rate [kg/s]
qmew,i | — | instantaneous exhaust mass flow rate [kg/s]
qmf,i | — | instantaneous fuel mass flow rate [kg/s]
qm,r | — | raw exhaust mass flow rate [kg/s]
r | — | cross-correlation coefficient
r2 | — | coefficient of determination
rh | — | hydrocarbon response factor
ugas | — | u value of the exhaust component ‘gas’
For the correct calculation of distance-specific emissions, the recorded traces of component concentrations, exhaust mass flow rate, vehicle speed, and other vehicle data shall be time corrected. To facilitate the time correction, data which are subject to time alignment shall be recorded either in a single data recording device or with a synchronised timestamp following paragraph 5.1. of Appendix 4. The time correction and alignment of parameters shall be carried out by following the sequence described in paragraphs 3.1. to 3.3.
The recorded traces of all component concentrations shall be time corrected by reverse shifting according to the transformation times of the respective analysers. The transformation time of analysers shall be determined according to paragraph 4.4. of Appendix 5.:
ci,ct Δtt,i ci,rt
where:
ci,c | | is the time-corrected concentration of component i as function of time t
ci,r | | is the raw concentration of component i as function of time t
Δtt,i | | is the transformation time t of the analyser measuring component i
The exhaust mass flow rate measured with an exhaust flow meter shall be time corrected by reverse shifting according to the transformation time of the exhaust mass flow meter. The transformation time of the mass flow meter shall be determined according to paragraph 4.4. of Appendix 5.:
qm,ct Δtt,m qm,rt
where:
qm,c | | is the time-corrected exhaust mass flow rate as function of time t
qm,r | | is the raw exhaust mass flow rate as function of time t
Δtt,m | | is the transformation time t of the exhaust mass flow meter
In case the exhaust mass flow rate is determined by ECU data or a sensor, an additional transformation time shall be considered and obtained by cross-correlation between the calculated exhaust mass flow rate and the exhaust mass flow rate measured following paragraph 4. of Appendix 6.
Other data obtained from a sensor or the ECU shall be time-aligned by cross-correlation with suitable emission data (e.g., component concentrations).
To time align vehicle speed with the exhaust mass flow rate, it is first necessary to establish one valid speed trace. In case vehicle speed is obtained from multiple sources (e.g., the GNSS, a sensor or the ECU), the speed values shall be time aligned by cross-correlation.
Vehicle speed shall be time aligned with the exhaust mass flow rate by cross-correlation between the exhaust mass flow rate and the product of vehicle speed and positive acceleration.
The time alignment of signals whose values change slowly and within a small value range, e.g. ambient temperature, can be omitted.
Any instantaneous emissions or exhaust flow measurements obtained while the combustion engine is deactivated shall be recorded in the data exchange file.
The drift correction shall be calculated in accordance with paragraph 5.0 of Annex 7 to UN Regulation No 168.
If the emissions are measured on a dry basis, the measured concentrations shall be converted to a wet basis as:
cwetkw cdry
where:
cwet | | is the wet concentration of a pollutant in ppm or per cent volume
cdry | | is the dry concentration of a pollutant in ppm or per cent volume
kw | | is the dry-wet correction factor
The following equation shall be used to calculate kw:
kw11 α 0,005 cco2 cco kw1 1,008
where:
kw11,608 Ha1 000 1,608 Ha
where:
Ha | | is the intake air humidity [g water per kg dry air]
cCO2 | | is the dry CO2 concentration [%]
cCO | | is the dry CO concentration [%]
α | | is the molar hydrogen ratio of the fuel (H/C)
NOx emissions shall not be corrected for ambient temperature and humidity.
Negative instantaneous results shall not be corrected.
The components in the raw exhaust shall be measured with the measurement and sampling analysers described in Appendix 5. The raw concentrations of relevant components shall be measured in accordance with Appendix 4. The data shall be time corrected and aligned in accordance with paragraph 3.
For methane measurement using a NMC-FID, the calculation of NMHC depends on the calibration gas/method used for the zero/span calibration adjustment. When a FID is used for THC measurement without a NMC, it shall be calibrated with propane/air or propane/N2 in the normal manner. For the calibration of the FID in series with a NMC, the following methods are permitted:
the calibration gas consisting of propane/air bypasses the NMC;
the calibration gas consisting of methane/air passes through the NMC.
It is strongly recommended to calibrate the methane FID with methane/air through the NMC.
In method (a), the concentrations of CH4 and NMHC shall be calculated as follows:
CCH4
CHCwo NMC 1 EM CHCwNMC
EE EM
CNMHC
CHCwNMC CHCwo NMC 1 EE
rh EE EM
In method (b), the concentration of CH4 and NMHC shall be calculated as follows:
CCH4
CHCwNMC rh 1 EM CHCwo NMC 1 EE
rh EE EM
CNMHC
CHCwo NMC 1 EM CHCwNMC rh 1 EM
EE EM
where:
cHC(w/oNMC) | | is the HC concentration with CH4 or C2H6 bypassing the NMC [ppmC1]
cHC(w/NMC) | | is the HC concentration with CH4 or C2H6 flowing through the NMC [ppmC1]
rh | | is the hydrocarbon response factor as determined in paragraph 4.3.3.(b) of Appendix 5
EM | | is the methane efficiency as determined in paragraph 4.3.4.(a) of Appendix 5
EE | | is the ethane efficiency as determined in paragraph 4.3.4.(b) of Appendix 5
If the methane FID is calibrated through the cutter (method b), then the methane conversion efficiency as determined in paragraph 4.3.4.(a) of Appendix 5 is zero. The density used for calculating the NMHC mass shall be equal to that of total hydrocarbons at 273.15 K and 101.325 kPa and is fuel-dependent.
The calculation of instantaneous mass emissions according to paragraphs 8. and 9. requires determining the exhaust mass flow rate. The exhaust mass flow rate shall be determined by one of the direct measurement methods specified in paragraph 7.2. of Appendix 5. Alternatively, it is permissible to calculate the exhaust mass flow rate as described in paragraphs 7.2. to 7.4 of this Appendix.
The instantaneous exhaust mass flow rate can be calculated from the air mass flow rate and the fuel mass flow rate as follows:
qmew,iqmaw,i qmf,i
where:
qmew,i | | is the instantaneous exhaust mass flow rate [kg/s]
qmaw,i | | is the instantaneous intake air mass flow rate [kg/s]
qmf,i | | is the instantaneous fuel mass flow rate [kg/s]
If the air mass flow rate and the fuel mass flow rate or the exhaust mass flow rate are determined from ECU recording, the calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust mass flow rate in paragraph 3. of Appendix 5 and the validation requirements specified in paragraph 4.3. of Appendix 6.
The instantaneous mass flow rate may be calculated in accordance with paragraph 7.3 of Annex 7 to UN Regulation No 168.
The instantaneous exhaust mass flow rate can be calculated from the fuel flow and the air-to-fuel ratio (calculated with A/Fst and λi according to paragraph 7.3.) as follows:
qmew,iqmaw,i 11AFst liqmew,iqmf,i 1 AFst li
The calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust gas mass flow rate in paragraph 3. of Appendix 5 and the validation requirements specified in paragraph 4.3. of Appendix 6.
The instantaneous mass emissions [g/s] shall be determined by multiplying the instantaneous concentration of the pollutant under consideration [ppm] with the instantaneous exhaust mass flow rate [kg/s], both corrected and aligned for the transformation time, and the respective u value in Table A7/1. If measured on a dry basis, the dry-wet correction in accordance with paragraph 5.2 shall be applied to the instantaneous component concentrations before executing any further calculations. If occurring, negative instantaneous emission values shall enter all subsequent data evaluations. Parameter values shall enter the calculation of instantaneous emissions [g/s] as reported by the analyser, flow-measuring instrument, sensor or the ECU. The following equation shall be applied:
mgas,iugas Cgas,i qmew,i
where:
mgas,i | | is the mass of the exhaust component ‘gas’ [g/s]
ugas | | is the ratio of the density of the exhaust component ‘gas’ and the overall density of the exhaust as listed in Table A7/1
cgas,i | | is the measured concentration of the exhaust component ‘gas’ in the exhaust [ppm]
qmew,i | | is the measured exhaust mass flow rate [kg/s]
gas | | is the respective component
i | | number of the measurement
[depending on fuel] [at λ = 2, dry air, 273 K, 101,3 kPa] [u values accurate within 0,2 % for mass composition of: C=66-76 %; H=22-25 %; N=0-12 %] [NMHC on the basis of CH2,93 (for THC the ugas coefficient of CH4 shall be used)] [u accurate within 0,2 % for mass composition of: C3=70-90 %; C4=10-30 %] [ugas is a unitless parameter; the ugas values include unit conversions to ensure that the instantaneous emissions are obtained in the specified physical unit, i.e., g/s]
Fuel | ρe [kg/m3] | Component or pollutant i
NOx | CO | HC | CO2 | O2 | CH4
ρgas [kg/m3]
2,052 | 1,249 | | 1,9630 | 1,4276 | 0,715
ugas,
Diesel (B0) | 1,2893 | 0,001593 | 0,000969 | 0,000480 | 0,001523 | 0,001108 | 0,000555
Diesel (B5) | 1,2893 | 0,001593 | 0,000969 | 0,000480 | 0,001523 | 0,001108 | 0,000555
Diesel (B7) | 1,2894 | 0,001593 | 0,000969 | 0,000480 | 0,001523 | 0,001108 | 0,000555
Ethanol (ED95) | 1,2768 | 0,001609 | 0,000980 | 0,000780 | 0,001539 | 0,001119 | 0,000561
CNG | 1,2661 | 0,001621 | 0,000987 | 0,000528 | 0,001551 | 0,001128 | 0,000565
Propane | 1,2805 | 0,001603 | 0,000976 | 0,000512 | 0,001533 | 0,001115 | 0,000559
Butane | 1,2832 | 0,001600 | 0,000974 | 0,000505 | 0,001530 | 0,001113 | 0,000558
LPG | 1,2811 | 0,001602 | 0,000976 | 0,000510 | 0,001533 | 0,001115 | 0,000559
Petrol (E0) | 1,2910 | 0,001591 | 0,000968 | 0,000480 | 0,001521 | 0,001106 | 0,000554
Petrol (E5) | 1,2897 | 0,001592 | 0,000969 | 0,000480 | 0,001523 | 0,001108 | 0,000555
Petrol (E10) | 1,2883 | 0,001594 | 0,000970 | 0,000481 | 0,001524 | 0,001109 | 0,000555
Ethanol (E85) | 1,2797 | 0,001604 | 0,000977 | 0,000730 | 0,001534 | 0,001116 | 0,000559
The instantaneous particle number emissions [particles/s] shall be determined by multiplying the instantaneous concentration of the pollutant under consideration [particles/cm3] with the instantaneous exhaust mass flow rate [kg/s], both corrected and aligned for the transformation time and by dividing with the density [kg/m3] according to Table A7/1. If applicable, negative instantaneous emission values shall enter all subsequent data evaluations. All significant digits of preceding results shall enter the calculation of the instantaneous emissions. The following equation shall apply:
PNiCPN,iqmew,iρe
where:
PNi | | is the particle number flux [particles/s]
cPN,i | | is the measured particle number concentration [#/m3] normalized at 0 °C
qmew,i | | is the measured exhaust mass flow rate [kg/s]
ρe | | is the density of the exhaust gas [kg/m3] at 0 °C (Table A7/1)
Data Exchange: The data shall be exchanged between the measurement systems and the data evaluation software by a standardised data exchange file provided by the Commission6.
Any pre-processing of data (e.g. time correction according to paragraph 3, vehicle speed correction according to paragraph 4.7 of Appendix 4 or the correction of the GNSS vehicle speed signal according to paragraph 6.5. of Appendix 4) shall be done with the control software of the measurement systems and shall be completed before the data exchange file is generated.