3 Appendix 1, Regulation (EU) 2017/1151

In forcesince 1 Jan 2019
1.

This Appendix describes the procedure to be used to verify the production conformity requirements for the Type 1 test for pollutants/CO2, including conformity requirements for PEVs and OVC-HEVs, and to monitor the OBFCM device accuracy.

2.

Measurements of the pollutants specified in Table 2 of Annex I to Regulation (EC) No 715/2007, and the emission of CO2 shall be carried out on a minimum number of 3 vehicles, and consecutively increase until a pass or fail decision is reached. The OBFCM device accuracy shall be determined for each of the N tests.

From the number of N tests: x1, x2, … xN, the average Xtests and the variance VAR are to be determined from all N measurements:

Xtestsx1 x2 x3 … xNN

and

VARx1 Xtests2 x2 Xtests2 … xN Xtests2N 1

3.

For each number of tests, one of the three following decisions (see (i) to ((iii) below) can be reached for pollutants based on the limit value L for each pollutant, the average of all N tests: Xtests, the variance of the test results VAR and the number of tests N:

(i)

Pass the family if XtestsA L VARL

(ii)

Fail the family if XtestsA L N 313 VARL

(iii)

Take another measurement if:

A L VARLXtestsA L N 313 VAR L

For the measurement of pollutants the factor A is set at 1,05 in order to take into account inaccuracies in the measurements.

4.

For CO2 and EC the normalised values for CO2 and EC shall be used:

xiCO2test iCO2declared.

xiECtest iECDC, COP

In the case of CO2 and EC the factor A is set at 1.01 and the value for L is set at 1. So in the case of CO2 and EC the criteria are simplified to:

(i)

Pass the family if XtestsA VAR

(ii)

Fail the family if XtestsA N 313 VAR

(iii)

Take another measurement if:

A VARXtestsA N 313 VAR

The A values for pollutants, EC and CO2 will be reviewed and may change according to the available evidence. For this reason the Type Approval Authorities will need to provide the Commission with all relevant data at least for the initial period of 5 years.

5.

For vehicles referred to in Article 4a, the accuracy of the OBFCM device shall be calculated as follows:

xi,OBFCMaccuracy of the OBFCM device determined for each single test i in accordance with the formulae point 4.2 of Annex XXII.

The Type Approval authority shall keep a record of the determined accuracies for each COP family tested.