The test sheet shall include the test data that are recorded, but not included in any test report.
The test sheet(s) shall be retained by the technical service or the manufacturer for at least 10 years.
The following information, if applicable, is the minimum data required for test sheets.
Information from Annex B4 to UN Regulation No 154
The coefficients, c0, c1 and c2 | : |
c0 =
c1 =
c2 =
The coastdown times measured on the chassis dynamometer | : | Reference speed (km/h) | Coastdown time (s)
130 |
120 |
110 |
100 |
90 |
80 |
70 |
60 |
50 |
40 |
30 |
20 |
Additional weight may be placed on or in the vehicle to eliminate tyre slippage | : |
weight (kg)
on/in the vehicle
The coastdown times after performing the vehicle coast down procedure | : | Reference speed (km/h) | Coastdown time (s)
130 |
120 |
110 |
100 |
90 |
80 |
70 |
60 |
50 |
40 |
30 |
20 |
Information from Annex B5 to UN Regulation No 154
NOx converter efficiency
Indicated concentrations (a); (b), (c), (d), and the concentration when the NOx analyser is in the NO mode so that the calibration gas does not pass through the converter
: |
=
=
=
=
Concentration in NO mode =
Information from Annex B6 to UN Regulation No 154
The distance actually driven by the vehicle | : |
For manual shift transmission vehicle, MT vehicle that cannot follow the cycle trace:
The deviations from the driving cycle
: |
Drive trace indices: | |
The following indices shall be calculated in accordance with the standard SAE J2951(Revised Jan-2014): |
:
:
IWR: Inertial Work Rating | : |
RMSSE: Root Mean Squared Speed Error |
:
:
:
Particulate sample filter weighing | |
Filter before the test | : |
Filter after the test | : |
Reference filter | : |
Content of each of the compounds measured after stabilization of the measuring device | : |
Regeneration factor determination | |
The number of cycles D between two WLTCs where regeneration events occur | : |
The number of cycles over which emission measurements are made n | : |
The mass emissions measurement M′sij for each compound i over each cycle j | : |
Regeneration factor determination
The number of applicable test cycles d measured for complete regeneration
: |
Regeneration factor determination | |
Msi | : |
Mpi | : |
Ki | : |
Information from Annex B6a to UN Regulation No 154
ATCT
The air temperature and humidity of the test cell measured at the vehicle cooling fan outlet at a minimum frequency of 0,1 Hz.
: |
Temperature set point = Treg
Actual temperature value
± 3 °C at the start of the test
± 5 °C during the test
The temperature of the soak area measured continuously at a minimum frequency of 0,033 Hz. | : |
Temperature set point = Treg
Actual temperature value
± 3 °C at the start of the test
± 5 °C during the test
The time of transfer from the preconditioning to the soak area | : | ≤ 10 minutes
The time between the end of the Type 1 test and the cool down procedure | : | ≤ 10 minutes
The measured soaking time, and shall be recorded in all relevant test sheets. | : | time between the measurement of the end temperature and the end of the Type 1 test at 23 °C
Information from Annex C3 to UN Regulation No 154
Diurnal testing
Ambient temperature during the two diurnal cycles (recorded at least every minute)
: | |
Carbon canister puff loss loading
Ambient temperature during the first 11-hour profile (recorded at least every 10 minutes)
: | |