30 Appendix 4, Regulation (EU) 2017/1151

In forcesince 1 Sep 2023

Test procedure for vehicle emissions testing with a portable emissions measurement system (PEMS)

This appendix describes the test procedure to determine pollutant emissions from passenger and light commercial vehicles using a Portable Emissions Measurement System.

pe | — | evacuated pressure [kPa]

qvs | — | volume flow rate of the system [l/min]

ppmC1 | — | parts per million carbon equivalent

Vs | — | system volume [l]

The test shall be carried out with a PEMS, composed of components specified in paragraphs 3.1.1. to 3.1.5. If applicable, a connection with the vehicle ECU may be established to determine relevant engine and vehicle parameters as specified in paragraph 3.2.

3.1.1. Analysers to determine the concentration of pollutants in the exhaust gas.

3.1.2. One or multiple instruments or sensors to measure or determine the exhaust mass flow.

3.1.3. A GNSS receiver to determine the position, altitude and, speed of the vehicle.

3.1.4. If applicable, sensors and other appliances being not part of the vehicle, e.g. to measure ambient temperature, relative humidity and air pressure.

3.1.5. An energy source independent of the vehicle to power the PEMS.

Test parameters, as specified in Table A4/1, shall be measured at a constant frequency of 1.0 Hz or higher and recorded and reported in accordance with the requirements of paragraph 10. of Appendix 7 at a sampling frequency of 1.0 Hz. If ECU parameters are obtained, these may be obtained at a substantially higher frequency but the recording rate shall be 1.0 Hz. The PEMS analysers, flow-measuring instruments and sensors shall comply with the requirements laid down in Appendices 5 and 6.

[Multiple parameter sources may be used.] [To be measured on a wet basis or to be corrected as described in paragraph 5.1. of Appendix 7.] [Parameter only mandatory if measurement required for compliance with the limits.] [May be calculated from THC and CH4 concentrations according to paragraph 6.2. to Appendix 7.] [May be calculated from measured NO and NO2 concentrations.] [Method to be chosen according to paragraph 4.7. of this Appendix.] [To be determined only if necessary to verify the vehicle status and operating conditions.] [The preferable source is the ambient pressure sensor.] [To be determined only if indirect methods are used to calculate exhaust mass flow rate as described in paragraphs 7.2. and 7.4. of Appendix 7.]

Parameter | Recommended unit | Source

THC concentration, (if applicable) | ppm C1 | Analyser

CH4 concentration,, (if applicable) | ppm C1 | Analyser

NMHC concentration,, (if applicable) | ppm C1 | Analyser

CO concentration,, | ppm | Analyser

CO2 concentration | ppm | Analyser

NOX concentration, | ppm | Analyser

PN concentration | #/m3 | Analyser

Exhaust mass flow rate | kg/s | EFM, any methods described in paragraph 7. of Appendix 5.

Ambient humidity | % | Sensor

Ambient temperature | K | Sensor

Ambient pressure | kPa | Sensor

Vehicle speed | km/h | Sensor, GNSS, or ECU

Vehicle latitude | Degree | GNSS

Vehicle longitude | Degree | GNSS

Vehicle altitude, | m | GNSS or Sensor

Exhaust gas temperature | K | Sensor

Engine coolant temperature | K | Sensor or ECU

Engine speed | RPM | Sensor or ECU

Engine torque | Nm | Sensor or ECU

Torque at driven axle (if applicable) | Nm | Rim torque meter

Pedal position | % | Sensor or ECU

Engine fuel flow (if applicable) | g/s | Sensor or ECU

Engine intake air flow (if applicable) | g/s | Sensor or ECU

Fault status | — | ECU

Intake air flow temperature | K | Sensor or ECU

Regeneration status (if applicable) | — | ECU

Engine oil temperature | K | Sensor or ECU

Actual gear | # | ECU

Desired gear (e.g. gear shift indicator) | # | ECU

Other vehicle data | unspecified | ECU

The installation of the PEMS shall follow the instructions of the PEMS manufacturer and the local health and safety regulations. When the PEMS is installed inside the vehicle, the vehicle should be equipped with gas monitors or warning systems for hazardous gases (e.g. CO). The PEMS should be installed as to minimise electromagnetic interferences during the test as well as exposure to shocks, vibration, dust and variability in temperature. The installation and operation of the PEMS shall be such that it avoids leakage and minimise heat loss. The installation and operation of PEMS shall not change the nature of the exhaust gas nor unduly increase the length of the tailpipe. To avoid the generation of particles, connectors shall be thermally stable at the exhaust gas temperatures expected during the test. It is recommended to avoid the use elastomer connectors to connect the vehicle exhaust outlet and the connecting tube. Elastomer connectors, if used, shall have no contact with the exhaust gas to avoid artefacts. If the test performed with the use of elastomer connectors fails, the test shall be repeated without the use of elastomer connectors.

The installation and operation of the PEMS sampling probes shall not unduly increase the pressure at the exhaust outlet in a way that may influence the representativeness of the measurements. It is thus recommended that only one sampling probe is installed in the same plane. If technically feasible, any extension to facilitate the sampling or connection with the exhaust mass flow meter shall have an equivalent, or larger, cross sectional area than the exhaust pipe.

Whenever used, the exhaust mass flow meter shall be attached to the vehicle’s tailpipe(s) in accordance with the recommendations of the EFM manufacturer. The measurement range of the EFM shall match the range of the exhaust mass flow rate expected during the test. It is recommended to select the EFM so that the maximum expected flow rate during the test reaches at least 75 per cent of the EFM full range but does not exceed the EFM full range. The installation of the EFM and any exhaust pipe adaptors or junctions shall not adversely affect the operation of the engine or exhaust after-treatment system. A minimum of four pipe diameters or 150 mm of straight tubing, whichever is larger, shall be placed at either side of the flow-sensing element. When testing a multi-cylinder engine with a branched exhaust manifold, it is recommended to position the exhaust mass flow meter downstream of where the manifolds combine and to increase the cross section of the piping such as to have an equivalent, or larger, cross sectional area from which to sample. If this is not feasible, exhaust flow measurements with several exhaust mass flow meters may be used. The wide variety of exhaust pipe configurations, dimensions and exhaust mass flow rates may require compromises, guided by good engineering judgement, when selecting and installing the EFM(s). It is permissible to install an EFM with a diameter smaller than that of the exhaust outlet or the total cross-sectional area of multiple outlets, providing it improves measurement accuracy and does not adversely affect the operation or the exhaust after-treatment as specified in paragraph 3.4.2. It is recommended to document the EFM set-up using photographs.

The GNSS antenna shall be mounted as near as possible to the highest location on the vehicle, so as to ensure good reception of the satellite signal. The mounted GNSS antenna shall interfere as little as possible with the vehicle operation.

If desired, relevant vehicle and engine parameters listed in Table A4/1 can be recorded by using a data logger connected with the ECU or the vehicle network through national or international standards, such as ISO 15031-5 or SAE J1979, OBD-II, EOBD or WWH-OBD. If applicable, manufacturers shall disclose labels to allow the identification of required parameters.

Vehicle speed sensors, temperature sensors, coolant thermocouples or any other measurement device not part of the vehicle shall be installed to measure the parameter under consideration in a representative, reliable and accurate manner without unduly interfering with the vehicle operation and the functioning of other analysers, flow-measuring instruments, sensors and signals. Sensors and auxiliary equipment shall be powered independently of the vehicle. It is permitted to power any safety-related illumination of fixtures and installations of PEMS components outside of the vehicle’s cabin by the vehicle’s battery.

Emissions sampling shall be representative and conducted at locations of well-mixed exhaust, where the influence of ambient air downstream of the sampling point is minimal. If applicable, emissions shall be sampled downstream of the exhaust mass flow meter, respecting a distance of at least 150 mm to the flow sensing element. The sampling probes shall be fitted at least 200 mm or three times the inner diameter of the exhaust pipe, whichever is larger, upstream of the point at which the exhaust gas exits the PEMS sampling installation into the environment.

If the PEMS feeds part of the sample back to the exhaust flow, this shall occur downstream of the sampling probe in a manner that does not affect the nature of the exhaust gas at the sampling point(s). If the length of the sampling line is changed, the system transport times shall be verified and, if necessary, corrected. If the vehicle is equipped with more than one tailpipe then all functioning tailpipes shall be connected before sampling and measuring exhaust flow.

If the engine is equipped with an exhaust after-treatment system, the exhaust sample shall be taken downstream of the exhaust after-treatment system. When testing a vehicle with a branched exhaust manifold, the inlet of the sampling probe shall be located sufficiently far downstream so as to ensure that the sample is representative of the average pollutant emissions of all cylinders. In multi-cylinder engines, having distinct groups of manifolds, such as in a ‘V’ engine configuration, the sampling probe shall be positioned downstream of where the manifolds combine. If this is technically not feasible, multi-point sampling at locations of well-mixed exhaust may be used. In this case, the number and location of sampling probes shall match as far as possible those of the exhaust mass flow meters. In case of unequal exhaust flows, proportional sampling or sampling with multiple analysers shall be considered.

If particles are measured, they shall be sampled from the centre of the exhaust stream. If several probes are used for emissions sampling, the particle sampling probe should be placed upstream of the other sampling probes. The particle sampling probe should not interfere with the sampling of gaseous pollutants. The type and specifications of the probe and its mounting shall be documented in detail (e.g. L type or 45° cut, internal diameter, with or without hat, etc).

If hydrocarbons are measured, the sampling line shall be heated to 463 ± 10 K (190 ± 10 °C). For the measurement of other gaseous components, with or without cooler, the sampling line shall be kept at a minimum of 333 K (60 °C) to avoid condensation and to ensure appropriate penetration efficiencies of the various gases. For low pressure sampling systems, the temperature can be lowered correspondingly to the pressure decrease provided that the sampling system ensures a penetration efficiency of 95 per cent for all regulated gaseous pollutants. If particles are sampled and not diluted at the tailpipe, the sampling line from the raw exhaust sample point to the point of dilution or particle detector shall be heated to a minimum of 373 K (100 °C). The residence time of the sample in the particle sampling line shall be less than 3 s until reaching first dilution or the particle detector.

All parts of the sampling system from the tailpipe up to the particle detector, which are in contact with raw or diluted exhaust gas, shall be designed to minimize deposition of particles. All parts shall be made from antistatic material to prevent electrostatic effects.

After the installation of the PEMS is completed, a leak check shall be performed at least once for each PEMS-vehicle installation as prescribed by the PEMS manufacturer or as follows. The probe shall be disconnected from the exhaust system and the end plugged. The analyser pump shall be switched on. After an initial stabilization period, all flow meters shall read approximately zero in the absence of a leak. If this is not the case the sampling lines shall be checked and the fault shall be corrected.

The leakage rate on the vacuum side shall not exceed 0.5 per cent of the in-use flow rate for the portion of the system being checked. The analyser flows and bypass flows may be used to estimate the in-use flow rate.

Alternatively, the system may be evacuated to a pressure of at least 20 kPa vacuum (80 kPa absolute). After an initial stabilization period the pressure increase Δp (kPa/min) in the system shall not exceed:

Δp

pe

Vs

qvs 0,005

where:

peis the evacuated pressure [Pa],

Vsis the system volume [l],

qvsis the volume flow rate of the system [l/min].

Alternatively, a concentration step change at the beginning of the sampling line shall be introduced by switching from zero to span gas while maintaining the same pressure conditions as under normal system operation. If for a correctly calibrated analyser after an adequate period of time the reading is ≤ 99 per cent compared to the introduced concentration, the leakage problem shall be corrected.

The PEMS shall be switched on, warmed up and stabilized in accordance with the specifications of the PEMS manufacturer until key functional parameters (e.g., pressures, temperatures and flows) have reached their operating set points before test start. To ensure correct functioning, the PEMS may be kept switched on or can be warmed up and stabilized during vehicle conditioning. The system shall be free of errors and critical warnings.

The sampling system, consisting of the sampling probe and sampling lines shall be prepared for testing by following the instruction of the PEMS manufacturer. It shall be ensured that the sampling system is clean and free of moisture condensation.

If used for measuring the exhaust mass flow, the EFM shall be purged and prepared for operation in accordance with the specifications of the EFM manufacturer. This procedure shall, if applicable, remove condensation and deposits from the lines and the associated measurement ports.

Zero and span calibration adjustments of the analysers shall be performed using calibration gases that meet the requirements of paragraph 5. of Appendix 5. The calibration gases shall be chosen to match the range of pollutant concentrations expected during the RDE test. To minimise analyser drift, it is recommended to conduct the zero and span calibration of analysers at an ambient temperature that resembles, as closely as possible, the temperature experienced by the test equipment during the trip.

The zero level of the analyser shall be recorded by sampling HEPA filtered ambient air at an appropriate sampling point, ideally at the inlet of the sampling line. The signal shall be recorded at a constant frequency which is a multiple of 1.0 Hz averaged over a period of 2 minutes. The final concentration shall be within the manufacturer’s specifications, but shall not exceed 5,000 particles per cubic-centimetre.

Vehicle speed shall be determined by at least one of the following methods:

(a)

a sensor (e.g., optical or micro-wave sensor); if vehicle speed is determined by a sensor, the speed measurements shall comply with the requirements of paragraph 8. of Appendix 5, or alternatively, the total trip distance determined by the sensor shall be compared with a reference distance obtained from a digital road network or topographic map. The total trip distance determined by the sensor shall deviate by no more than 4 per cent from the reference distance.

(b)

the ECU; if vehicle speed is determined by the ECU, the total trip distance shall be validated according to paragraph 3. of Appendix 6 and the ECU speed signal adjusted, if necessary, to fulfil the requirements of paragraph 3. of Appendix 6. Alternatively, the total trip distance as determined by the ECU can be compared with a reference distance obtained from a digital road network or topographic map. The total trip distance determined by the ECU shall deviate by no more than 4 per cent from the reference distance.

(c)

a GNSS; if vehicle speed is determined by a GNSS, the total trip distance shall be checked against the measurements of another method according to paragraph 6.5. of Appendix 4.

The correctness of connections with all sensors and, if applicable, the ECU shall be verified. If engine parameters are retrieved, it shall be ensured that the ECU reports values correctly (e.g., zero engine speed [rpm] while the combustion engine is in key-on-engine-off status). The PEMS shall function free of errors and critical warnings.

Sampling, measurement and recording of parameters shall begin prior to the test start (as defined in point 2.6.5. of this Annex). Before the test start it shall be confirmed that all necessary parameters are recorded by the data logger.

To facilitate time alignment, it is recommended to record the parameters that are subject to time alignment either by a single data recording device or with a synchronised time stamp.

Sampling, measurement and recording of parameters shall continue throughout the on-road test of the vehicle. The engine may be stopped and started, but emissions sampling and parameter recording shall continue. Repeated stalling of the engine (i.e. unintentional stopping of the engine) should be avoided during an RDE trip. Any warning signals, suggesting malfunctioning of the PEMS, shall be documented and verified. If any error signal(s) appear during the test, the test shall be invalid. Parameter recording shall reach a data completeness of higher than 99 per cent. Measurement and data recording may be interrupted for less than 1 per cent of the total trip duration but for no more than a consecutive period of 30 s solely in the case of unintended signal loss or for the purpose of PEMS system maintenance. Interruptions may be recorded directly by the PEMS but it is not permissible to introduce interruptions in the recorded parameter via the pre-processing, exchange or post-processing of data. If conducted, auto zeroing shall be performed against a traceable zero standard similar to the one used to zero the analyser. It is strongly recommended to initiate PEMS system maintenance during periods of zero vehicle speed.

Excessive idling of the engine after the completion of the trip shall be avoided. The data recording shall continue after the test end (as defined in paragraph 2.6.6. of this Annex) and until the response time of the sampling systems has elapsed. For vehicles with a signal detecting regeneration, the OBD-check shall be performed and documented directly after data recording and before any further driven distance is driven.

The zero and span of the analysers of gaseous components shall be checked by using calibration gases identical to the ones applied under paragraph 4.5. to evaluate the analyser's zero and response drift compared to the pre-test calibration. It is permissible to zero the analyser prior to verifying the span drift, if the zero drift was determined to be within the permissible range. The post-test drift check shall be completed as soon as possible after the test and before the PEMS, or individual analysers or sensors, are turned off or have switched into a non-operating mode. The difference between the pre-test and post-test results shall comply with the requirements specified in Table A4/2.

[If the zero drift is within the permissible range, it is permissible to zero the analyser prior to verifying the span drift.]

Pollutant | Absolute Zero response drift | Absolute Span response drift

CO2 | ≤ 2000 ppm, per test | ≤ 2 % of reading or ≤ 2000 ppm per test, whichever is larger

CO | ≤ 75 ppm per test | ≤ 2 % of reading or ≤ 75 ppm per test, whichever is larger

NOX | ≤ 3 ppm per test | ≤ 2 % of reading or ≤ 3 ppm per test, whichever is larger

CH4 | ≤ 10 ppm C1 per test | ≤ 2 % of reading or ≤ 10 ppm C1 per test, whichever is larger

THC | ≤ 10 ppm C1 per test | ≤ 2 % of reading or ≤ 10 ppm C1 per test, whichever is larger

If the difference between the pre-test and post-test results for the zero and span drift is higher than permitted, all test results shall be invalid and the test repeated.

The zero level of the analyser shall be recorded in accordance with paragraph 4.6.

The span gas concentration that was used for the calibration of the analysers in accordance with paragraph 4.5. at the test start shall cover at least 90 per cent of the concentration values obtained from 99 per cent of the measurements of the valid parts of the emissions test. It is permissible that 1 per cent of the total number of measurements used for evaluation exceeds the concentration of the span gas used by up to a factor of two. If these requirements are not met, the test shall be invalid.

In case altitude has only been measured with a GNSS, the GNSS altitude data shall be checked for consistency and, if necessary, corrected. The consistency of data shall be checked by comparing the latitude, longitude and altitude data obtained from the GNSS with the altitude indicated by a digital terrain model or a topographic map of suitable scale. Measurements that deviate by more than 40 m from the altitude depicted in the topographic map shall be manually corrected. The original and uncorrected data shall be retained and any corrected data shall be marked.

The instantaneous altitude data shall be checked for completeness. Data gaps shall be completed by data interpolation. The correctness of interpolated data shall be verified by a topographic map. It is recommended to correct interpolated data if the following condition applies:

hGNSSt hmapt 40 m

The altitude correction shall be applied so that:

ht hmapt 40 m

where:

h(t) | — | vehicle altitude after the screening and principle check of data quality at data point t [m above sea level]

hGNSS(t) | — | vehicle altitude measured with GNSS at data point t [m above sea level]

hmap(t) | — | vehicle altitude based on topographic map at data point t [m above sea level]