1.1. This Appendixappendix describes the procedure of the test according to section 2 of this Annex.
2.1. The technical requirements and specifications shall be those set out in Appendix 1 to Annex 11 to UN/ECE Regulation No 83 with the exceptions and additional requirements as described in the following sections.
2.2. The references in Appendix 1 to Annex 11 to UN/ECE Regulation No 83 to the OBD threshold limits set out in paragraph 3.3.2 to Annex 11 of UN/ECE Regulation No 83 shall be understood as references to the OBD threshold limits set out in section 2.3 of this Annex.
2.3. The reference fuels specified in paragraph 3.2 of Appendix 1 of Annex 11 of UN/ECE Regulation No 83 shall be understood as reference to the appropriate reference fuel specifications in Annex IX to this Regulation.
2.4. The reference to Annex 11 in paragraph 6.5.1.4 of Appendix 1 of Annex 11 of UN/ECE Regulation No 83 shall be understood as reference to Annex XI to this Regulation.
2.5. The following text shall be added as a new final sentence to the second paragraph of Section 1 of Appendix 1 to Annex 11 of UN/ECE Regulation No 83.
‘For electrical failures (short/open circuit), the emissions may exceed the limits of paragraph 3.3.2. by more than twenty per cent.’
2.6. Paragraph 6.5.3. of Appendix 1 to Annex 11 of UN/ECE Regulation No 83 shall be replaced with the following:
‘6.5.3. The emission control diagnostic system shall provide for standardised and unrestricted access and conform with the following ISO standards and/or SAE specification. Later versions may be used at the manufacturers' discretion.
6.5.3.1. The following standard shall be used as the on board to off-board communications link:
(a) ISO 15765-4:2011 “Road vehicles – Diagnostics on Controller Area Network (CAN) – Part 4: Requirements for emissions-related systems”, dated 1 February 2011;
6.5.3.2. Standards used for the transmission of OBD relevant information:
(a) ISO 15031-5 “Road vehicles - communication between vehicles and external for the type 2 test equipment for emissions-related diagnostics – Part 5: Emissions-related diagnostic services”, dated 1 April 2011 or SAE J1979 dated 23 February 2012;
(b) ISO 15031-4 “Road vehicles – Communication between vehicle and external test equipment for , measuring carbon monoxide emissions related diagnostics – Part 4: External test equipment”, dated 1 June 2005 or SAE J1978 dated 30 April 2002;
(c) ISO 15031-3 “Road vehicles – Communication between vehicle and external test equipment for emissions related diagnostics Part 3: Diagnostic connector and related electrical circuits: specification and use”, dated 1 July 2004 or SAE J 1962 dated 26 July 2012;
(d) ISO 15031-6 “Road vehicles – Communication between vehicle and external test equipment for emissions related diagnostics – Part 6: Diagnostic trouble code definitions”, dated 13 August 2010 or SAE J2012 dated 07 March 2013;
(e) ISO 27145 “Road vehicles – Implementation of World-Wide Harmonized On-Board Diagnostics (WWH-OBD)” dated 2012-08-15 with the restriction, that only 6.5.3.1.(a) may be used as a data link;
(f) ISO 14229:2013 “Road vehicles – Unified diagnostic services (UDS) with the restriction, that only 6.5.3.1.(a) may be used as a data link”.
The standards (e) and (f) may be used as an option instead of (a) not earlier than 1 January 2019.
6.5.3.3. Test equipment and diagnostic tools needed to communicate with OBD systems shall meet or exceed the functional specification given in the standard listed in paragraph 6.5.3.2.(b) of this Appendix.
6.5.3.4. Basic diagnostic data, (as specified in paragraph 6.5.1.) and bi-directional control information shall be provided using the format and units described in the standard listed in paragraph 6.5.3.2.(a) of this appendix, and must be available using a diagnostic tool meeting the at engine idling speeds (normal and high).
2.1. The general requirements of the standard listed in paragraph 6.5.3.2.(b) of this appendix.
The vehicle manufacturer shall provide to a national standardisation body the details of any emission-related diagnostic data, e.g. PID’s, OBD monitor Id’s, Test Id’s not specified in the standard listed in paragraph 6.5.3.2.(a) of this Regulation but related to this Regulation.
6.5.3.5. When a fault is registered, the manufacturer shall identify the fault using an appropriate ISO/SAE controlled fault code specified in one of the standards listed in paragraph 6.5.3.2.(d) of this appendix, relating to “emission related system diagnostic trouble codes”. If such identification is not possible, the manufacturer may use manufacturer controlled diagnostic trouble codes according to the same standard. The fault codes shall be fully accessible by standardised diagnostic equipment complying with the provisions of paragraph 6.5.3.2. of this Appendix.
The vehicle manufacturer shall provide to a national standardisation body the details of any emission-related diagnostic data, e.g. PID’s, OBD monitor Id’s, Test Id’s not be those specified in the standards listed in paragraph 6.section 5.3.2.(a) of this Appendix but related to this Regulation.
6.5.3.6. The connection interface between the vehicle and the diagnostic tester shall be standardised and shall meet all the requirements of the standard listed in paragraph 6. and paragraphs 5.3.2.(c) of this appendix. The installation position shall be subject to agreement of the administrative department such that it is readily accessible by service personnel but protected from tampering by non-qualified personnel.
6.7.1 to 5.3.7. The manufacturer shall also make accessible, where appropriate on payment, the technical information required for the repair or maintenance of motor vehicles unless that information is covered by an intellectual property right or constitutes essential, secret know-how which is identified in an appropriate form; in such case, the necessary technical information shall not be withheld improperly.
Entitled to such information is any person engaged in commercially servicing or repairing, road-side rescuing, inspecting or testing of vehicles or in the manufacturing or selling replacement or retro-fit components, diagnostic tools and test equipment.’
2.6. A new paragraph 6.1.1. of Appendix 1 to Annex 11 of 6 of UN/ECE Regulation No 83 shall be inserted as follows:
‘6.1.1. The Type I Test need not be performed for the demonstration of electrical failures (short/open circuit). The manufacturer may demonstrate these failure modes using driving conditions in which the component is used and the monitoring conditions are encountered. These conditions shall be documented in the type approval documentation.’
2.7. Paragraph 6.2.2. of Appendix 1 of Annex 11 of UN/ECE Regulation No 83 shall be amended to read as follows:
‘At the request of the manufacturer, alternative and/or additional preconditioning methods may be used.’
2.8. A new paragraph 6.2.3. of Appendix 1 to Annex 11 of UN/ECE Regulation No 83 shall be inserted as follows:
‘6.2.3. The use of additional preconditioning cycles or alternative preconditioning methods shall be documented in the type approval documentation.’
2.9. Paragraph 6.3.1, with the exception set out in section 2.2.
2.2. The table referred to in paragraph 5.3.7.5. of Appendix 1 to Annex 11 of UN/ECE Regulation No 83 shall be replaced with the following:
‘Electrical disconnection of the electronic evaporative purge control device (if equipped and if active on the selected fuel type).’
2.10. Paragraph 6.4.1.1. of Appendix 1 to Annex 11 of UN/ECE Regulation No 83 shall be replaced with the following:
‘The MI shall be activated at the latest before the end of this understood as the table for the Type 2 test under any of the conditions given in paragraphs 6.4.1.2. to 6.4.1.5. The MI may also be activated during preconditioning. The Technical Service may substitute those conditions with others in accordance with paragraph 6.4.1.6.’
2.11. Paragraph 6.4.2.1. of Appendix 1 in section 2.1 the Addendum to Appendix 4 to Annex 11 of UN/ECEI to this Regulation No 83 shall be replaced with the following:
‘The MI shall be activated at the latest before the end of this test under any of the conditions given in paragraphs 6.4.2.2. to 6.4.2.5. The MI may also be activated during preconditioning. The Technical Service may substitute those conditions by others in accordance with paragraph 6.4.2.5.’
The .
3.1. The technical requirements and specifications shall be those set out in Appendix 1 to Annex 115 to UN/ECE Regulation No 83, with the exceptions and additional requirements as described in the following set out in sections.
3.1.1. The requirements of paragraph 7.1.5 of Appendix 1 to Annex 11 to UN/ECE Regulation No 83 shall be understood as being as follows.
For new type approvals and new vehicles the monitor required by point 2.9 of this Annex shall have an IUPR greater or equal to 0,1 until three years after the dates specified in Article 10(4) and (5) of Regulation (EC) No 715/2007 respectively.
3.1.2. The requirements of paragraph 7.1.7 of Appendix 1 to 3.2. and 3.3.
3.2. The reference fuel specifications referred to in paragraph 2.1 of Annex 115 to UN/ECE Regulation No 83 shall be understood as being as follows.
The manufacturer shall demonstrate referring to the approval authority and, upon request, to the Commission that these statistical conditions are satisfied for all monitors required to be reported by the OBD system according to paragraph 7.6. of Appendix 1 to appropriate reference fuel specifications in Annex 11 to Regulation No 83 not later than 18 months after the entry onto the market of the first vehicle type with IUPR in an OBD family and every 18 months thereafter. For IX to this purpose, for OBD families consisting of more than 1000 registrations in the Union, that are subject to sampling within the sampling period, the process described in Annex II shall be used without prejudice to the provisions of paragraph 7.1.9. of Appendix 1 to Annex 11 to Regulation No 83.
In addition to the requirements set out in Annex II and regardless of the result of the audit described in Section 2 of Annex II, the authority granting the approval shall apply the in-service conformity check for IUPR described in Appendix 1 to Annex II in an appropriate number of randomly determined cases. ‘In an appropriate number of randomly determined cases’ means, that this measure has a dissuasive effect on non-compliance with the requirements of Section 3 of this Annex or the provision of manipulated, false or non-representative data for the audit. If no special circumstances apply and can be demonstrated by the type-approval authorities, random application of the in-service conformity check to 5 % of the type approved OBD families shall be considered as sufficient for compliance with this requirement. For this purpose, type-approval authorities may find arrangements with the manufacturer for the reduction of double testing of a given OBD family as long as these arrangements do not harm the dissuasive effect of the type-approval authority’s own in-service conformity check on non-compliance with the requirements of Section 3 of this Annex. Data collected by Member States during surveillance testing programmes may be used for in-service conformity checks. Upon request, type-approval authorities shall provide data on the audits and random in-service conformity checks performed, including the methodology used for identifying those cases, which are made subject to the random in-service conformity check, to the Commission and other type-approval authorities.
3.1.3. Non-compliance with the requirements of .
3.3. Reference to the Type I test in paragraph 7.1.6. of Appendix 1 to Annex 11 to Regulation No 83 established by tests described in point 3.1.2 of this Appendix or paragraph 7.1.9 of Appendix 1 to 2.2.1. of Annex 11 to Regulation No 83 shall be considered as an infringement subject to the penalties set out in Article 13 of Regulation (EC) No 715/2007. This reference does not limit the application of such penalties to other infringements of other provisions of Regulation (EC) No 715/2007 or this Regulation, which do not explicitly refer to Article 13 of Regulation (EC) No 715/2007.
3.1.4. Paragraph 7.6.1. of Appendix 1 to Annex 11 of 5 to UN/ECE Regulation No 83 shall be replaced with the following:
‘7.6.1. The OBD system shall report, in accordance with the standard listed in paragraph 6.5.3.2.(a) of this Appendix, the ignition cycle counter and general denominator as well as separate numerators and denominators for the following monitors, if their presence on the vehicle is required by this annex:
(a) Catalysts (each bank to be reported separately);
(b) Oxygen/exhaust gas sensors, including secondary oxygen sensors
(each sensor to be reported separately);
(c) Evaporative system;
(d) EGR system;
(e) VVT system;
(f) Secondary air system;
(g) Particulate filter;
(h) NOx after-treatment system (e.g. NOx absorber, NOx reagent/catalyst system);
(i) Boost pressure control system.’
Paragraph 7.6.2. of Appendix 1 to understood as referring to the Type 1 test in Annex 11 of UN/ECE Regulation No 83 shall be replaced with the following:
‘7.6.2. For specific components or systems that have multiple monitors, which are required to be reported by XXI to this point (e.g. oxygen sensor bank 1 may have multiple monitors for sensor response or other sensor characteristics), the OBD system shall separately track numerators and denominators for each of the specific monitors and report only the corresponding numerator and denominator for the specific monitor that has the lowest numerical ratio. If two or more specific monitors have identical ratios, the corresponding numerator and denominator for the specific monitor that has the highest denominator shall be reported for the specific component.’
A new paragraph 7.6.2.1. of Appendix 1 to Annex 11 of UN/ECE Regulation No 83 shall be inserted as follows:
‘7.6.2.1. Numerators and denominators for specific monitors of components or systems, that are monitoring continuously for short circuit or open circuit failures are exempted from reporting.
“Continuously,” if used in this context means monitoring is always enabled and sampling of the signal used for monitoring occurs at a rate no less than two samples per second and the presence or the absence of the failure relevant to that monitor has to be concluded within 15 seconds.
If for control purposes, a computer input component is sampled less frequently, the signal of the component may instead be evaluated each time sampling occurs.
It is not required to activate an output component/system for the sole purpose of monitoring that output component/system.’.