39 Appendix 15, Regulation (EU) 2022/1379

In forcesince 5 Jul 2022

This Appendix describes the list of parameters to be provided by the component manufacturer as input to the simulation tool. The applicable XML schema as well as example data are available at the dedicated electronic distribution platform.

(1)

“parameter ID”: Unique identifier as used in the simulation tool for a specific input parameter or set of input data

(2)

“type”: Data type of the parameter

string… | sequence of characters in ISO8859-1 encoding

token… | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace

date… | date and time in UTC time in the format: YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. “2002-05-30T09:30:10Z”

integer… | value with an integral data type, no leading zeros, e.g. “1800”

double, X… | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for “double, 2”: “2345,67”; for “double, 4”: “45,6780”

(3)

“unit” … physical unit of the parameter

Parameter name | Parameter ID | Type | Unit | Description/Reference

Manufacturer | P450 | token | [-] |

Model | P451 | token | [-] |

CertificationNumber | P452 | token | [-] |

Date | P453 | dateTime | [-] | Date and time when the component-hash is created

AppVersion | P454 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data

ElectricMachineType | P455 | string | [-] |

Determined in accordance with point 21 of paragraph 2 of this Annex.

Allowed values: “ASM”, “ESM”, “PSM”, “RM”

CertificationMethod | P456 | string | [-] | Allowed values: “Measurement”, “Standard values”

R85RatedPower | P457 | integer | [W] | Determined in accordance with paragraph 1.9 of Annex 2 to UN Regulation No. 85 Rev. 1

RotationalInertia | P458 | double, 2 | [kgm2] | Determined in accordance with point 8 of Appendix 8 of this Annex.

DcDcConverterIncluded | P465 | boolean | [-] | Set to “true” where a DC/DC converter is part of the electric machine system, in accordance with paragraph 4.1 of this Annex

IHPCType | P466 | string | [-] | Allowed values: “None”, “IHPC Type 1”

Parameter name | Parameter ID | Type | Unit | Description/Reference

VoltageLevel | P467 | integer | [V] | Where the parameter “CertificationMethod” is “Standard values”, no input needs to be provided.

ContinuousTorque | P459 | double, 2 | [Nm] |

TestSpeedContinuousTorque | P460 | double, 2 | [1/min] |

OverloadTorque | P461 | double, 2 | [Nm] |

TestSpeedOverloadTorque | P462 | double, 2 | [1/min] |

OverloadDuration | P463 | double, 2 | [s] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

OutputShaftSpeed | P468 | double, 2 | [1/min] |

MaxTorque | P469 | double, 2 | [Nm] |

MinTorque | P470 | double, 2 | [Nm] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

OutputShaftSpeed | P471 | double, 2 | [1/min] |

DragTorque | P472 | double, 2 | [Nm] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

OutputShaftSpeed | P473 | double, 2 | [1/min] |

Torque | P474 | double, 2 | [Nm] |

ElectricPower | P475 | double, 2 | [W] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

CoolantTempInlet | P476 | integer | [°C] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex.

CoolingPower | P477 | integer | [W] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex.

Parameter name | Parameter ID | Type | Unit | Description/Reference

Manufacturer | P478 | token | [-] |

Model | P479 | token | [-] |

CertificationNumber | P480 | token | [-] |

Date | P481 | dateTime | [-] | Date and time when the component-hash is created

AppVersion | P482 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data

ElectricMachineType | P483 | string | [-] |

Determined in accordance with point 21 of paragraph 2 of this Annex.

Allowed values: “ASM”, “ESM”, “PSM”, “RM”

CertificationMethod | P484 | string | [-] |

Allowed values: “Measured for complete component”,

“Measured for EM and standard values for other components”, “Standard values for all components”

R85RatedPower | P485 | integer | [W] | Determined in accordance with paragraph 1.9 of Annex 2 to UN Regulation No. 85

RotationalInertia | P486 | double, 2 | [kgm2] | Determined in accordance with point 8 of Appendix 8 of this Annex.

DifferentialIncluded | P493 | boolean | [-] | Set to “true” in the case a differential is part of the IEPC

DesignTypeWheelMotor | P494 | boolean | [-] | Set to “true” in the case of an IEPC design type wheel motor

NrOf DesignTypeWheelMotorMeasured | P495 | integer | [-] |

Input only relevant in the case of an IEPC design type wheel motor, in accordance with paragraph 4.1.1.2 of this Annex.

Allowed values: “1”, “2”

Parameter name | Parameter ID | Type | Unit | Description/Reference

GearNumber | P496 | integer | [-] |

Ratio | P497 | double, 3 | [-] | Ratio of electric machine rotor speed over IEPC output shaft speed

MaxOutputShaftTorque | P498 | integer | [Nm] | optional

MaxOutputShaftSpeed | P499 | integer | [1/min] | optional

Parameter name | Parameter ID | Type | Unit | Description/Reference

VoltageLevel | P500 | integer | [V] | Where the parameter “CertificationMethod” is “Standard values for all components”, no input needs to be provided.

ContinuousTorque | P487 | double, 2 | [Nm] |

TestSpeedContinuousTorque | P488 | double, 2 | [1/min] |

OverloadTorque | P489 | double, 2 | [Nm] |

TestSpeedOverloadTorque | P490 | double, 2 | [1/min] |

OverloadDuration | P491 | double, 2 | [s] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

OutputShaftSpeed | P501 | double, 2 | [1/min] |

MaxTorque | P502 | double, 2 | [Nm] |

MinTorque | P503 | double, 2 | [Nm] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

OutputShaftSpeed | P504 | double, 2 | [1/min] |

DragTorque | P505 | double, 2 | [Nm] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

OutputShaftSpeed | P506 | double, 2 | [1/min] |

Torque | P507 | double, 2 | [Nm] |

ElectricPower | P508 | double, 2 | [W] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

CoolantTempInlet | P509 | integer | [°C] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex.

CoolingPower | P510 | integer | [W] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex.

Parameter name | Parameter ID | Type | Unit | Description/Reference

Manufacturer | P511 | token | [-] |

Model | P512 | token | [-] |

CertificationNumber | P513 | token | [-] |

Date | P514 | dateTime | [-] | Date and time when the component-hash is created

AppVersion | P515 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data

CertificationMethod | P517 | string | [-] | Allowed values: “Measured”, “Standard values”

BatteryType | P518 | string | [-] | Allowed values: “HPBS”, “HEBS”

RatedCapacity | P519 | double, 2 | [Ah] |

ConnectorsSubsystemsIncluded | P520 | boolean | [-] | Only relevant if representative battery sub-system is tested: Set to “true” if representative cable harness for connecting battery sub-systems was included in testing. Always set to “true” if complete battery system was tested.

JunctionboxIncluded | P511 | boolean | [-] | Only relevant if representative battery sub-system is tested: Set to “true” if representative junction box with shut-off device and fuses was included in testing. Always set to “true” if complete battery system was tested.

TestingTemperature | P521 | integer | [°C] |

Determined in accordance with paragraph 5.1.4 of this Annex.

Where the parameter “CertificationMethod” is “Standard values”, no input needs to be provided.

Parameter name | Parameter ID | Type | Unit | Description/Reference

SOC | P522 | integer | [%] |

OCV | P523 | double, 2 | [V] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

SOC | P524 | integer | [%] | Where the parameter “CertificationMethod” is “Standard values”, the same DCIR values shall be provided for two different SOC values of 0 % and 100 %.

DCIR RI2 | P525 | double, 2 | [mOhm] | Where the parameter “CertificationMethod” is “Standard values”, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided.

DCIR RI10 | P526 | double, 2 | [mOhm] | Where the parameter “CertificationMethod” is “Standard values”, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided.

DCIR RI20 | P527 | double, 2 | [mOhm] | Where the parameter “CertificationMethod” is “Standard values”, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided.

DCIR RI120 | P528 | double, 2 | [mOhm] |

Optional, only required for batteries of type HEBS.

In the event the parameter “CertificationMethod” is “Standard values”, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided.

Parameter name | Parameter ID | Type | Unit | Description/Reference

SOC | P529 | integer | [%] | Where the parameter “CertificationMethod” is “Standard values”, the same values for MaxChargingCurrent as well as MaxDischargingCurrent shall be provided for two different SOC values of 0 % and 100 %.

MaxChargingCurrent | P530 | double, 2 | [A] |

MaxDischargingCurrent | P531 | double, 2 | [A] |

Parameter name | Parameter ID | Type | Unit | Description/Reference

Manufacturer | P532 | token | [-] |

Model | P533 | token | [-] |

CertificationNumber | P534 | token | [-] |

Date | P535 | dateTime | [-] | Date and time when the component-hash is created

AppVersion | P536 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data

CertificationMethod | P538 | string | [-] | Allowed values: “Measurement”, “Standard values”

Capacitance | P539 | double, 2 | [F] |

InternalResistance | P540 | double, 2 | [Ohm] |

MinVoltage | P541 | double, 2 | [V] |

MaxVoltage | P542 | double, 2 | [V] |

MaxChargingCurrent | P543 | double, 2 | [A] |

MaxDischargingCurrent | P544 | double, 2 | [A] |

TestingTemperature | P532 | integer | [°C] |

Determined in accordance with paragraph 6.1.3 of this Annex.

Where the parameter “CertificationMethod” is “Standard values”, no input needs to be provided.

(*) determined in accordance with points 4.3.5 and 4.3.6 of this Annex

(**) determined in accordance with points 5.4.1.4 of this Annex

(***) UN Regulation No. 100 of the Economic Commission for Europe of the United Nations (UNECE) — Uniform provisions concerning the approval of vehicles with regard to specific requirements for the electric powertrain (OJ L449, 15.12.2021 p. 1).