Information document no.:
Issue:
Date of issue:
Date of Amendment:
pursuant to …
Electric machine system type / family (if applicable):
…
GENERAL
0.1. Name and address of manufacturer
0.2. Make (trade name of manufacturer):
0.3. Electric machine system type:
0.4. Electric machine system family:
0.5. Electric machine system type as separate technical unit / Electric machine system family as separate technical unit
0.6. Commercial name(s) (if available):
0.7. Means of identification of model, if marked on the Electric machine system:
0.8. In the case of components and separate technical units, location and method of affixing of the EC approval mark:
0.9. Name(s) and address(es) of assembly plant(s):
0.10. Name and address of the manufacturer's representative:
|Parent EMS | |Family members
|or EMS type | |
| | | #1 | | #2 | | #3 | |
General
1.1. Test voltage(s): V
1.2. Basic motor rotational speed: 1/min
1.3. Motor output shaft maximum speed: 1/min
1.4. (or by default) reducer/gearbox outlet shaft speed: 1/min
1.5. Maximum power speed: 1/min
1.6. Maximum power: kW
1.7. Maximum torque speed: 1/min
1.8. Maximum torque: Nm
1.9. Maximum 30 minutes power: kW
Electric machine
2.1. Working principle
2.1.1. Direct current (DC)/alternating current (AC):
2.1.2. Number of phases:
2.1.3. Excitation / separate / series / compound:
2.1.4. Synchron / asynchron:
2.1.5. Rotor coiled / with permanent magnets / with housing:
2.1.6. Number of poles of the motor:
2.2. Rotational inertia: kgm2
Power controller
3.1. Make:
3.2. Type:
3.3. Working principle:
3.4. Control principle: vectorial / open loop / closed / other (t.b.s.):
3.5. Maximum effective current supplied to the motor: A
3.6. For maximum duration of: s
3.7. DC voltage range used (from / to): V
3.8. DC/DC converter is part of the electric machine system in accordance with paragraph 4.1 of this Annex (yes/no):
Cooling system
4.1. Motor (liquid / air / other t.b.s.):
4.2. Controller (liquid / air / other t.b.s.):
4.3. Description of the system:
4.4. Principle drawing(s):
4.5. Temperature boundary limits (min/max): K
4.6. At reference position:
4.7. Flow rates (min/max): ltr/min
Documented values from component testing
5.1. Efficiency figures for CoP [determined in accordance with points 4.3.5 and 4.3.6 of this Annex]:
5.2. Cooling system (declaration for each cooling circuit):
5.2.1. maximum coolant mass flow or volume flow or maximum inlet pressure:
5.2.2. maximum coolant temperatures:
5.2.3. maximum available cooling power:
5.2.4. Recorded average values for each test run
5.2.4.1. coolant volume flow or mass flow:
5.2.4.2. coolant temperature at the inlet of the cooling circuit:
5.2.4.3. coolant temperature at the inlet and outlet of the test bed heat exchanger on the side of the EMS:
No.: | Description: | Date of issue:
1 | Information on EMS test conditions … |
2 | … |
Information on test conditions (if applicable)
1.1 | …