48 3. ASSESSMENT, Decision_act (EU) 2021/534

In forcesince 24 Mar 2021cited 1×

According to the German authority, the technical solution provided by Orona does not satisfy the essential requirements mainly because the lift deviates from EN 81-1 in that it provides for only 0,5 m vertical distance instead of 1 m from the car roof to the well ceiling. The German authority considers that this does not allow sufficient time for a person to assume a safe position in case other precautionary measures fail to stop the lift at a greater distance. However, the German authority did not specify in the national measure in which cases the vertical distance in the M33v3 lift would be 0,5 m and consequently, in which cases the risk of crushing may appear.

  • Arrêt du Tribunal (troisième chambre) du 13 septembre 2023. République fédérale d'Allemagne contre Commission européenne.Decision

    En l’espèce, ainsi que la Commission l’a rappelé au considérant 48 de la décision attaquée, l’autorité centrale des Länder, lorsqu’elle a adopté la mesure de sauvegarde, a estimé que la solution technique fournie par Orona …

    13 Sep 2023 · 62021TJ0349