Orona recalled in its observations of 18 May 2016 that rather than focusing merely on how the M33v3 model compares to the harmonised standards concerning vertical headroom, which is merely one factor in evaluating lift safety, an overall safety assessment is required. In this respect, Orona referred to the position paper of NB-L, the coordination group of notified bodies for Directive 95/16/EC of 3 November 2009, entitled ‘Crushing danger, free space, criteria’, which sets criteria for acceptable free space equivalent to the criteria set out in clause 5.7 of EN 81-1. The criteria set out in that position paper are based on a combination of the free vertical space, a free space volume (cube) and the integration of those spaces in the spatial area. The same position paper contains a non-exhaustive list of additional criteria that must be taken into account during a risk assessment. Those additional criteria include warnings, ergonomic principles, frequency of maintenance and unexpected circumstances.
26 2. POSITIONS AND ARGUMENTS OF THE PARTIES › 2.2. Position and arguments of Orona, Decision_act (EU) 2021/534
In forcesince 24 Mar 2021
- celex=31995L0016