AccuracyThe closeness of agreement between test method results and accepted reference values. It is a measure of test method performance and one aspect of “relevance”. The term is often used interchangeably with “concordance”, to mean the proportion of correct outcomes of a test method (29).
AOP (Adverse Outcome Pathway)Sequence of events from the chemical structure of a target chemical or group of similar chemicals through the molecular initiating event to an in vivo outcome of interest (2).
AREAntioxidant response element (also called EpRE, electrophile response element), is a response element found in the upstream promoter region of many cytoprotective and phase II genes. When activated by Nfr2, it mediates the transcriptional induction of these genes.
ChemicalA substance or a mixture.
Coefficient of variationA measure of variability that is calculated for a group of replicate data by dividing the standard deviation by the mean. It can be multiplied by 100 for expression as a percentage.
EC1,5Interpolated concentration for a 1,5 fold luciferase induction.
IC30Concentration effecting a reduction of cellular viability by 30 %.
IC50Concentration effecting a reduction of cellular viability by 50 %.
HazardInherent property of an agent or situation having the potential to cause adverse effects when an organism, system or (sub) population is exposed to that agent.
IATA (Integrated Approach to Testing and Assessment)A structured approach used for hazard identification (potential), hazard characterisation (potency) and/or safety assessment (potential/potency and exposure) of a chemical or group of chemicals, which strategically integrates and weights all relevant data to inform regulatory decision regarding potential hazard and/or risk and/or the need for further targeted and therefore minimal testing.
ImaxMaximal induction factor of luciferase activity compared to the solvent (negative) control measured at any test chemical concentration.
Keap1Kelch-like ECH-associated protein 1, is a sensor protein that can regulate the Nrf2 activity. Under un-induced conditions the Keap1 sensor protein targets the Nrf2 transcription factor for ubiquitinylation and proteolytic degradation in the proteasome. Covalent modification of the reactive cysteine residues of Keap 1 by small molecules can lead to dissociation of Nrf2 from Keap1 (8) (10) (11).
MixtureA mixture or a solution composed of two or more substances in which they do not react (1).
Mono-constituent substanceA substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w).
Multi-constituent substanceA substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction.
Nrf2Nuclear factor (erythroid-derived 2)-like 2, is a transcription factor involved in the antioxidant response pathway. When Nrf2 is not ubiquitinylated, it builds up in the cytoplasm and translocates into the nucleus, where it combines to the ARE in the upstream promoter region of many cytoprotective genes, initiating their transcription (8) (10) (11).
Positive controlA replicate containing all components of a test system and treated with a substance known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive.
RelevanceDescription of relationship of the test to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test method (29).
ReliabilityMeasures of the extent that a test method can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility and intra-laboratory repeatability (29).
ReproducibilityThe agreement among results obtained from testing the same chemical using the same test protocol (see reliability) (29).
SensitivityThe proportion of all positive / active chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results, and is an important consideration in assessing the relevance of a test method (29).
Solvent/vehicle controlA replicate containing all components of a test system except of the test chemical, but including the solvent that is used. It is used to establish the baseline response for the samples treated with the test chemical dissolved in the same solvent.
SpecificityThe proportion of all negative / inactive chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results and is an important consideration in assessing the relevance of a test method (29).
SubstanceChemical elements and their compounds in the natural state or obtained by any production process, including any additive necessary to preserve the stability of the product and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing its composition (1).
Test chemicalThe term “test chemical” is used to refer to what is being tested.
United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS)A system proposing the classification of chemicals (substances and mixtures) according to standardised types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (1).
UVCBSubstances of unknown or variable composition, complex reaction products or biological materials.
Valid test methodA test method considered to have sufficient relevance and reliability for a specific purpose and which is based on scientifically sound principles. A test method is never valid in an absolute sense, but only in relation to a defined purpose (29).