An operator must establish operational procedures for re/defuelling with passengers embarking, on board or disembarking to ensure the following precautions are taken:
one qualified person must remain at a specified location during fuelling operations with passengers on board. This qualified person must be capable of handling emergency procedures concerning fire protection and fire-fighting, handling communications and initiating and directing an evacuation;
a two-way communication shall be established and shall remain available by the aeroplane's inter-communication system or other suitable means between the ground crew supervising the refuelling and the qualified personnel on board the aeroplane;
crew, staff and passengers must be warned that re/defuelling will take place;
“Fasten Seat Belts” signs must be off;
“NO SMOKING” signs must be on, together with interior lighting to enable emergency exits to be identified;
passengers must be instructed to unfasten their seat belts and refrain from smoking;
the minimum required number of cabin crew specified by OPS 1.990 must be on board and be prepared for an immediate emergency evacuation;
if the presence of fuel vapour is detected inside the aeroplane, or any other hazard arises during re/defuelling, fuelling must be stopped immediately;
the ground area beneath the exits intended for emergency evacuation and slide deployment areas must be kept clear; and
provision is made for a safe and rapid evacuation.