1.1. The manufacturer shall ensure that the engine’s ventilation system does not permit the emission of any crankcase gases into the atmosphere. For the purpose of type-approval the manufacturer shall provide the granting approval authority with a signed declaration of compliance as regards the crankcase emissions requirements of vehicles with positive ignition engines.
1.2. A template for the manufacturer’s declaration of compliance with the Type 3 requirements is laid down in Appendix 1 of this Annex.
1.3. In the case a granting approval authority requests a demonstration test at type-approval or in case of conformity of production testing, in-service conformity or market surveillance checks this Annex describes the procedure for the type 3 test verifying emissions of crankcase gases as described in section 5.3.3 of UN Regulation No 83.
2.1. The general requirements for conducting the type 3 test shall be those set out in sections 1 and 2 of Annex 6 to UN Regulation No 83, with the exceptions set out in point 2.2 below.
2.2 The road load coefficients to be used shall be those for vehicle low (VL). If VL does not exist, then the VH road load shall be used. In that case VH is defined in accordance with point 4.2.1.1.1 of Annex B4 to UN Regulation No 154. In case the interpolation method is used VL and VH are specified in point 4.2.1.1.2 of Annex B4 to UN Regulation No 154.
3.1 The technical requirements shall be those set out in sections 3 to 6 of Annex 6 to UN Regulation No 83.