ANNEX IV, Regulation (EU) 2018/1832

In forcesince 27 Nov 2018

This Annex provides the method to determine the levels of evaporative emission from light-duty vehicles in a repeatable and reproducible manner designed to be representative of real world vehicle operation.

For the purposes of this Annex, the following definitions shall apply:

3.1.1.

“Accuracy” means the difference between a measured value and a reference value, traceable to a national standard and describes the correctness of a result.

3.1.2.

“Calibration” means the process of setting a measurement system's response so that its output agrees with a range of reference signals.

3.2.1.

“Charge-depleting operating condition” means an operating condition in which the energy stored in the Rechargeable Electric Energy Storage System (REESS) may fluctuate but decreases on average while the vehicle is driven until transition to charge-sustaining operation.

3.2.2.

“Charge-sustaining operating condition” means an operating condition in which the energy stored in the REESS may fluctuate but, on average, is maintained at a neutral charging balance level while the vehicle is driven.

3.2.3.

“Not off-vehicle charging hybrid electric vehicle” (NOVC-HEV) means a hybrid electric vehicle that cannot be charged from an external source.

3.2.4.

“Off-vehicle charging hybrid electric vehicle” (OVC-HEV) means a hybrid electric vehicle that can be charged from an external source.

3.2.5.

“Hybrid electric vehicle” (HEV) means a hybrid vehicle where one of the propulsion energy converters is an electric machine.

3.2.6.

“Hybrid vehicle” (HV) means a vehicle equipped with a powertrain containing at least two different categories of propulsion energy converters and at least two different categories of propulsion energy storage systems.

3.3.1.

“Fuel tank system” means the devices which allow storing the fuel, comprising the fuel tank, the fuel filler, the filler cap and the fuel pump when it is fitted in or on the fuel tank.

3.3.2.

“Fuel system” means the components which store or transport fuel on board the vehicle and comprise the fuel tank system, all fuel and vapour lines, any non-tank mounted fuel pumps and the activated carbon canister.

3.3.3.

“Butane working capacity” (BWC) means the mass of butane which a canister can adsorb.

3.3.4.

“BWC300” means the butane working capacity after 300 cycles of fuel ageing cycles experienced.

3.3.5.

“Permeability Factor” (PF) means the factor determined from hydrocarbon losses over a period of time and used to determine the final evaporative emissions.

3.3.6.

“Monolayer non-metal tank” means a fuel tank constructed with a single layer of non-metal material including fluorinated/sulfonated materials.

3.3.7.

“Multilayer tank” means a fuel tank constructed with at least two different layered materials, one of which is a hydrocarbon barrier material.

3.3.8.

“Sealed fuel tank system” means a fuel tank system where the fuel vapours do not vent during parking over the 24-hour diurnal cycle defined in Appendix 2 to Annex 7 of UN/ECE Regulation No 83 when performed with a reference fuel defined in Section A.1 of Annex IX to this Regulation.

3.3.9.

“Evaporative emissions” means in the context of this Regulation the hydrocarbon vapours lost from the fuel system of a motor vehicle during parking and immediately before refuelling of a sealed fuel tank.

3.3.10.

“Mono-fuel gas vehicle” means a mono-fuel vehicle that runs primarily on liquefied petroleum gas, natural gas/biomethane, or hydrogen but may also have a petrol system for emergency purposes or starting only, where the petrol tank does not contain more than 15 litres of petrol.

3.3.11.

“Depressurisation puff loss” means hydrocarbons venting from a sealed fuel tank system pressure relief exclusively through the vapour storage unit allowed by the system.

3.3.12.

“Depressurisation puff loss overflow” are the depressurisation puff loss hydrocarbons that pass through the vapour storage unit during depressurisation.

3.3.13.

“Fuel tank relief pressure” is the minimum pressure value at which the sealed fuel tank system starts venting in response only to pressure inside the tank.

3.3.14.

“Auxiliary canister” is the canister used to measure depressurisation puff loss overflow.

3.3.15.

“2 gram breakthrough” shall be considered accomplished when the cumulative quantity of hydrocarbons emitted from the activated carbon canister equals 2 grams.

BWC | Butane working capacity

PF | Permeability factor

APF | Assigned permeability factor

OVC-HEV | Off-vehicle charging hybrid electric vehicle

NOVC-HEV | Not off-vehicle charging hybrid electric vehicle

WLTC | Worldwide light-duty test cycle

REESS | Rechargeable electric energy storage system

5.1.

The vehicle and its components liable to affect the evaporative emissions shall be designed, constructed and assembled so as to enable the vehicle in normal use and under normal conditions of use such as humidity, rain, snow, heat, cold, sand, dirt, vibrations, wear, etc. to comply with the provisions of this Regulation during its useful life.

5.1.1.

This shall include the security of all hoses, joints and connections used within the evaporative emission control systems.

5.1.2.

For vehicles with a sealed fuel tank system, this shall also include having a system which, just before refuelling, releases the tank pressure exclusively through a vapour storage unit which has the sole function of storing fuel vapour. This ventilation route shall also be the only one used when the tank pressure exceeds its safe working pressure.

5.2.

The test vehicle shall be selected in accordance with paragraph 5.5.2.

5.3.1.

The types and amounts of lubricants and coolant for emissions testing shall be as specified for normal vehicle operation by the manufacturer.

5.3.2.

The type of fuel for testing shall be as specified in Section A.1 of Annex IX.

5.3.3.

All evaporative emissions controlling systems shall be in working order.

5.3.4.

The use of any defeat device is prohibited in accordance with the provisions of Article 5(2) of Regulation (EC) No 715/2007.

5.4.1.

The provisions for electronic system security shall be those specified in paragraph 2.3. of Annex I.

5.5.1.

Only vehicles that are identical with respect to the characteristics listed in (a), (c) and (d), technically equivalent with respect to the characteristics listed in (b) and similar or, where applicable, within the stated tolerance regarding the characteristics listed in (e) and (f) may be part of the same evaporative emission family:

(a)

Fuel tank system material and construction;

(b)

Vapour hose material, fuel line material and connection technique;

(c)

Sealed tank or non-sealed tank system;

(d)

Fuel tank relief valve setting (air ingestion and relief);

(e)

Canister butane working capacity (BWC300) within a 10 per cent range of the highest value (for canisters with the same type of charcoal, the volume of charcoal shall be within 10 per cent of that for which the BWC300 was determined);

(f)

Purge control system (for example, type of valve, purge control strategy).

5.5.2.

The vehicle shall be considered to produce worst-case evaporative emissions and shall be used for testing if it has the largest ratio of fuel tank capacity to canister butane working capacity within the family. The vehicle selection shall be agreed in advance with the approval authority.

5.5.3.

The use of any innovative system calibration, configuration, or hardware related to the evaporative control system shall place the vehicle model in a different family.

Each of the evaporative emission families defined in paragraph 5.5.1. shall be attributed a unique identifier of the following format:

EV-nnnnnnnnnnnnnnn-WMI-x

Where:

nnnnnnnnnnnnnnn is a string with a maximum of fifteen characters, restricted to using the characters 0-9, A-Z and the underscore character ‘_’.

WMI (world manufacturer identifier) is a code that identifies the manufacturer in a unique manner defined in ISO 3780:2009.

x shall be set to ‘1’ or ‘0’ in accordance with the following provisions:

(a)

With the agreement of the approval authority and the owner of the WMI, the number shall be set to ‘1’ where a vehicle family is defined for the purpose of covering vehicles of:

(i)

a single manufacturer with one single WMI code;

(ii)

a manufacturer with several WMI codes, but only in cases when one WMI code is to be used;

(iii)

more than one manufacturer, but only in cases when one WMI code is to be used.

In the cases (i), (ii) and (iii), the family identifier code shall consist of one unique string of n-characters and one unique WMI code followed by ‘1’.

(b)

With the agreement of the approval authority, the number shall be set to ‘0’ in the case that a vehicle family is defined based on the same criteria as the corresponding vehicle family defined in accordance with point (a), but the manufacturer chooses to use a different WMI. In this case the family identifier code shall consist of the same string of n-characters as the one determined for the vehicle family defined in accordance with point (a) and a unique WMI code which shall be different from any of the WMI codes used under case (a), followed by ‘0’.

5.6.

The approval authority shall not grant type approval if the information provided is insufficient to demonstrate that the evaporative emissions are effectively limited during the normal use of the vehicle.

The limit value shall be that specified in Table 3 of Annex I to Regulation (EC) No 715/2007.

This Annex describes the procedure for the Type 4 test which determines the evaporative emission of vehicles.

2.1.

The procedure includes the evaporative emissions test and two additional tests, one for the ageing of carbon canisters, as described in paragraph 5.1. of this Appendix, and one for the permeability of the fuel tank system, as described in paragraph 5.2. of this Appendix. The evaporative emissions test (Figure VI.4) determines hydrocarbon evaporative emissions as a consequence of diurnal temperature fluctuations and hot soaks during parking.

2.2.

In the case that the fuel system contains more than one carbon canister, all references to the term “canister” in this Annex shall apply to each canister.

The vehicle shall be in good mechanical condition and have been run-in and driven at least 3000 km before the test. For the purpose of the determination of evaporative emissions, the mileage and the age of the vehicle used for certification shall be included in all relevant test reports. The evaporative emission control system shall be connected and functioning correctly during the run-in period. A carbon canister aged in accordance with the procedure described in paragraph 5.1. of this Appendix shall be used.

The chassis dynamometer shall meet the requirements of paragraph 2. of Sub-Annex 5 of Annex XXI.

The evaporative emission measurement enclosure shall meet the requirements of paragraph 4.2. of Annex 7 of UN/ECE Regulation No 83.

The analytical systems shall meet the requirements of paragraph 4.3. of Annex 7 of UN/ECE Regulation No 83. Continuous measuring of hydrocarbons is not mandatory unless the fixed volume type enclosure is used.

The temperature recording shall meet the requirements of paragraph 4.5. of Annex 7 of UN/ECE Regulation No 83.

The pressure recording shall meet the requirements of paragraph 4.6. of Annex 7 of UN/ECE Regulation No 83, except that the accuracy and resolution of the pressure recording system defined in paragraph 4.6.2. of Annex 7 of UN/ECE Regulation No 83 shall be:

(a)

Accuracy: ± 0,3 kPa

(b)

Resolution: 0,025 kPa

The fans shall meet the requirements of paragraph 4.7. of Annex 7 of UN/ECE Regulation No 83, except that the capacity of the blowers shall be 0,1 to 0,5 m3/sec instead of 0,1 to 0,5 m3/min.

The gases shall meet the requirements of paragraph 4.8. of Annex 7 of UN/ECE Regulation No 83.

The additional equipment shall meet the requirements of paragraph 4.9. of Annex 7 of UN/ECE Regulation No 83.

The auxiliary canister should be identical to the main canister but not necessarily aged. The connection tube to the vehicle canister shall be as short as possible. The auxiliary canister shall be fully-purged with dry air prior to loading.

The canister weighing scale shall have an accuracy of ±0,02 g.

Before performing the hot soak and diurnal losses sequences, the canister shall be aged in accordance with the procedure described in Figure VI.1.

The canister shall be cycled between temperatures from – 15 °C to 60 °C in a dedicated temperature enclosure with 30 minutes of stabilisation at – 15 °C and 60 °C. Each cycle shall last 210 minutes (see Figure VI.2).

The temperature gradient shall be as close as possible to 1 °C/min. No forced air flow should pass through the canister.

The cycle shall be repeated 50 times consecutively. In total, this procedure lasts 175 hours.

Following the temperature ageing procedure, the canister shall be shaken vertically with the canister mounted as per its orientation in the vehicle with an overall Grms > 1,5 m/sec2 with a frequency of 30 ± 10 Hz. The test shall last 12 hours.

5.1.3.1.

Ageing shall consist of repeatedly loading with fuel vapour and purging with laboratory air.

5.1.3.1.1.

After temperature and vibration ageing, the canister shall be further aged with a mixture of market fuel as specified in paragraph 5.1.3.1.1.1. of this Appendix and nitrogen or air with a 50 ± 15 per cent fuel vapour volume. The fuel vapour fill rate shall be 60 ± 20 g/h.

The canister shall be loaded to 2 gram breakthrough. As an alternative, loading shall be deemed to be completed when the hydrocarbon concentration level at the vent outlet reaches 3000 ppm.

5.1.3.1.1.1.

The market fuel used for this test shall fulfil the same requirements as a reference fuel with respect to:

(a)

Density at 15 °C;

(b)

Vapour pressure;

(c)

Distillation (70 °C, 100 °C, 150 °C);

(d)

Hydrocarbon analysis (olefins, aromatics, benzene only);

(e)

Oxygen content;

(f)

Ethanol content.

5.1.3.1.2.

The canister shall be purged between 5 and 60 minutes after loading with 25 ± 5 litres per minute of emission laboratory air until 300 bed volume exchanges are reached.

5.1.3.1.3.

The procedures set out in paragraphs 5.1.3.1.1. and 5.1.3.1.2. of this Appendix shall be repeated 300 times after which the canister shall be considered to be stabilised.

5.1.3.1.4.

The procedure to measure the butane working capacity (BWC) with respect to the evaporative emission family in paragraph 5.5. shall consist of the following.

(a)

The stabilised canister shall be loaded to 2 gram breakthrough and subsequently purged a minimum of 5 times. Loading shall be performed with a mixture composed of 50 per cent butane and 50 per cent nitrogen by volume at a rate of 40 grams butane per hour.

(b)

Purging shall be performed in accordance with paragraph 5.1.3.1.2. of this Appendix.

(c)

The BWC shall be included in all relevant test reports after each loading.

(d)

BWC300 shall be calculated as the average of the last 5 BWCs.

5.1.3.2.

If an aged canister is provided by a supplier, the manufacturer shall inform the approval authority in advance of the ageing process to enable the witnessing of any part of that process in the supplier's facilities.

5.1.3.3.

The manufacturer shall provide the approval authority a test report including at least the following elements:

(a)

Type of activated carbon;

(b)

Loading rate;

(c)

Fuel specifications.

5.2.1.

The fuel tank system representative of a family shall be selected and mounted on a rig in a similar orientation as in the vehicle. The tank shall be filled to 40 ± 2 per cent of its nominal capacity with reference fuel at a temperature of 18 °C ± 2 °C. The rig with the fuel tank system shall be placed in a room with a controlled temperature of 40 °C ± 2 °C for 3 weeks.

5.2.2.

At the end of the third week, the tank shall be drained and refilled with reference fuel at a temperature of 18 °C ± 2 °C to 40 ± 2 per cent of its nominal tank capacity.

Within 6 to 36 hours, the rig with the fuel tank system shall be placed in an enclosure. The last 6 hours of this period shall be at an ambient temperature of 20 °C ± 2 °C. In the enclosure, a diurnal procedure shall be performed over the first 24-hour period of the procedure described in paragraph 6.5.9. of this Appendix. The fuel vapour in the tank shall be vented to the outside of the enclosure to eliminate the possibility of the tank venting emissions being counted as permeation. The HC emissions shall be measured and the value shall be included in all relevant test reports as HC3W.

5.2.3.

The rig with the fuel tank system shall be placed again in a room with a controlled temperature of 40 °C ± 2 °C for the remaining 17 weeks.

5.2.4.

At the end of the seventeenth week, the tank shall be drained and refilled with reference fuel at a temperature of 18 °C ± 2 °C to 40 ± 2 per cent of its nominal tank capacity.

Within 6 to 36 hours, the rig with the fuel tank system shall be placed in an enclosure. The last 6 hours of this period shall be at an ambient temperature of 20 °C ± 2 °C. In the enclosure, a diurnal procedure shall be performed over a first period of 24 hours of the procedure described in accordance with paragraph 6.5.9. of this Appendix. The fuel tank system shall be vented to the outside of the enclosure to eliminate the possibility of the tank venting emissions being counted as permeation. The HC emissions shall be measured and the value shall be included in all relevant test reports in this case as HC20W.

5.2.5.

The PF is the difference between HC20W and HC3W in g/24h calculated to 3 significant digits using the following equation:

PF = HC20w – HC3W

5.2.6.

If the PF is determined by a supplier, the vehicle manufacturer shall inform the approval authority in advance of the determination to allow witness check in the supplier's facility.

5.2.7.

The manufacturer shall provide the approval authority with a test report containing at least the following:

(a)

A full description of the fuel tank system tested, including information on the type of tank tested, whether the tank is metal, monolayer non-metal or multilayer, and which types of materials are used for the tank and other parts of the fuel tank system;

(b)

The weekly mean temperatures at which the ageing was performed;

(c)

The HC measured at week 3 (HC3W);

(d)

The HC measured at week 20 (HC20W);

(e)

The resulting permeability factor (PF).

5.2.8.

As an alternative to paragraphs 5.2.1. to 5.2.7. of this Appendix, a manufacturer using multilayer tanks or metal tanks may choose to use an Assigned Permeability Factor (APF) instead of performing the complete measurement procedure mentioned above:

APF multilayer/metal tank = 120 mg /24 h

Where the manufacturer chooses to use an APF, the manufacturer shall provide the approval authority with a declaration in which the type of tank is clearly specified as well as a declaration of the type of materials used.

The vehicle shall be prepared in accordance to paragraphs 5.1.1. and 5.1.2. of Annex 7 of UN/ECE Regulation No 83. At the request of the manufacturer and with approval of the approval authority, non-fuel background emission sources (e.g. paint, adhesives, plastics, fuel/vapour lines, tyres, and other rubber or polymer components) may be reduced to typical vehicle background levels before testing (e.g. baking of tyres at temperatures of 50 °C or higher for appropriate periods, baking of the vehicle, draining washer fluid).

For a sealed fuel tank system, the vehicle canisters shall be installed so that access to canisters and connection/disconnection of canisters can be done easily.

6.2.1.

For vehicles with manual shift transmissions, the gear shift prescriptions specified in Sub-Annex 2 of Annex XXI shall apply.

6.2.2.

In the case of pure ICE vehicles, the mode shall be selected in accordance with Sub-Annex 6 of Annex XXI.

6.2.3.

In the case of NOVC-HEVs and OVC-HEVs, the mode shall be selected in accordance with Appendix 6 to Sub-Annex 8 of Annex XXI.

6.2.4.

Upon request of the approval authority, the selected mode may be different from that described in paragraphs 6.2.2. and 6.2.3. of this Appendix.

The tests included in this Annex shall be performed using the test conditions specific to interpolation family vehicle H with the highest cycle energy demand of all the interpolation families included in the evaporative emission family being considered.

Alternatively, at the request of the approval authority, any cycle energy representative of a vehicle in the family may be used for the test.

The test procedure for non-sealed and sealed tank systems shall be followed in accordance with the flow chart described in Figure VI.4.

The sealed fuel tank systems shall be tested with one of 2 options. One option is to test the vehicle with one continuous procedure. Another option, called the stand-alone procedure, is to test the vehicle with two separate procedures which will allow repeating the dynamometer test and the diurnal tests without repeating the tank depressurisation puff loss overflow test and the depressurisation puff loss measurement.

The fuel tank of the vehicle shall be emptied. This shall be done so as not to abnormally purge or abnormally load the evaporative control devices fitted to the vehicle. Removal of the fuel cap is normally sufficient to achieve this. The fuel tank shall be refilled with reference fuel at a temperature of 18 °C ± 2 °C to 40 ± 2 per cent of its nominal capacity.

Within 5 minutes after completing fuel drain and refill, the vehicle shall be soaked for a minimum of 6 hours and a maximum of 36 hours at 23 °C ± 3 °C.

The vehicle shall be placed on a chassis dynamometer and driven over the following phases of the cycle described in Sub-Annex 1 of Annex XXI:

(a)

For Class 1 vehicles: low, medium, low, low, medium, low

(b)

For Class 2 and 3 vehicles: low, medium, high, medium.

For OVC-HEVs, the preconditioning drive shall be performed under the charge-sustaining operating condition as defined in paragraph 3.3.6. of Annex XXI. Upon the request of approval authority, any other mode may be used.

Within one hour after the preconditioning drive, the fuel tank of the vehicle shall be emptied. This shall be done so as not to abnormally purge or abnormally load the evaporative control devices fitted to the vehicle. Removal of the fuel cap is normally sufficient to achieve this. The fuel tank shall be refilled with test fuel at a temperature of 18 °C ± 2 °C to 40 ± 2 per cent of its nominal capacity.

This article is long: the rest is at the official publication.