The engine test procedure described in this Annex shall produce input data relating to engines for the simulation tool.
For the purposes of this Annex the definitions set out in UN Regulation No. 49 [Regulation No. 49 of the Economic Commission for Europe of the United Nations (UN/ECE) – Uniform provisions concerning the measures to be taken against the emission of gaseous and particulate pollutants from compression-ignition engines and positive ignition engines for use in vehicles (OJ L 171, 24.6.2013, p. 1).] and, in addition to these, the following definitions shall apply:
‘engine CO2-family’ means a manufacturer's grouping of engines, as defined in paragraph 1 of Appendix 3;
‘CO2-parent engine’ means an engine selected from an engine CO2-family as specified in Appendix 3;
‘NCV’ means net calorific value of a fuel as specified in paragraph 3.2;
‘specific mass emissions’ means the total mass emissions divided by the total engine work over a defined period expressed in g/kWh;
‘specific fuel consumption’ means the total fuel consumption divided by the total engine work over a defined period expressed in g/kWh;
‘FCMC’ means fuel consumption mapping cycle;
‘Full load’ means the delivered engine torque/power at a certain engine speed when the engine is operated at maximum operator demand;
‘Waste Heat Recovery system’ or ‘WHR system’ means all devices converting energy from the exhaust gas or from operating fluids in engine cooling systems into electrical or mechanical energy;
‘WHR system with no external output’ or ‘WHR_no_ext’ means a WHR system which generates mechanical energy and is mechanically connected to the engine crankshaft in order to feed its generated energy directly back to the engine crankshaft;
‘WHR system with external mechanical output’ or ‘WHR_mech’ means a WHR system which generates mechanical energy and feeds it to other elements in the vehicle’s drivetrain than the engine or to a rechargeable storage;
‘WHR system with external electrical output’ or ‘WHR_elec’ means a WHR system which generates electrical energy and feeds it to the vehicle’s electric circuit or to a rechargeable storage;
‘P_WHR_net’ means the net power generated by a WHR system in accordance with point 3.1.6;
‘E_WHR_net’ means the net energy generated by a WHR system over a certain amount of time determined by integrating P_WHR_net;
The definitions set out in paragraphs 3.1.5 and 3.1.6 of Annex 4 to UN Regulation No. 49 shall not apply.
The calibration laboratory facilities shall comply with the requirements of either IATF 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national or international standards.
Engines shall be grouped into engine CO2-families defined in accordance with Appendix 3. Paragraph 4.1 explains which testruns shall be performed for the purpose of certification of one specific engine CO2-family.
All testruns performed for the purpose of certification of one specific engine CO2-family defined in accordance with Appendix 3 to this Annex shall be conducted on the same physical engine and without any changes to the setup of the engine dynamometer and the engine system, apart from the exceptions defined in paragraph 4.2 and Appendix 3.
The tests shall be conducted under ambient conditions meeting the following conditions over the whole testrun:
The parameter ‘fa’ describing the laboratory test conditions, determined in accordance with paragraph 6.1 of Annex 4 to UN Regulation No. 49, shall be within the following limits: 0,96 ≤ fa ≤ 1,04.
The absolute temperature (Ta) of the engine intake air expressed in Kelvin, determined in accordance with paragraph 6.1 of Annex 4 to UN Regulation No. 49 shall be within the following limits: 283 K ≤ Ta ≤ 303 K.
The atmospheric pressure expressed in kPa, determined in accordance with paragraph 6.1 of Annex 4 to UN Regulation No. 49 shall be within the following limits: 90 kPa ≤ ps ≤ 102 kPa.
If tests are performed in test cells that are able to simulate barometric conditions other than those existing in the atmosphere at the specific test site, the applicable fa value shall be determined with the simulated values of atmospheric pressure by the conditioning system. The same reference value for the simulated atmospheric pressure shall be used for the intake air and exhaust path and all other relevant engine systems. The actual value of the simulated atmospheric pressure for the intake air and exhaust path and all other relevant engine systems shall be within the limits specified in subpoint (3).
In cases where the ambient pressure in the atmosphere at the specific test site exceeds the upper limit of 102 kPa, tests in accordance with this Annex may still be performed. In this case tests shall be performed with the specific ambient air pressure in the atmosphere.
In cases where the test cell has the ability to control temperature, pressure and/or humidity of engine intake air independent of the atmospheric conditions the same settings for those parameters shall be used for all testruns performed for the purpose of certification of one specific engine CO2-family defined in accordance with Appendix 3 to this Annex.
The test engine shall be installed in accordance with paragraphs 6.3 to 6.6 of Annex 4 to UN Regulation No. 49.
If auxiliaries/equipment necessary for operating the engine system are not installed as required in accordance with paragraph 6.3 of Annex 4 to UN Regulation No. 49, all measured engine torque values shall be corrected for the power required for driving these components for the purpose of this Annex in accordance with paragraph 6.3 of Annex 4 to UN Regulation No. 49.
Such corrections of engine torque and power values shall be performed if the sum of absolute values of additional or missing engine torque required for driving these engine components in a specific engine operation point exceeds the torque tolerances defined in accordance with paragraph 4.3.5.5 (1) subparagraph (b). Where such an engine component is operated in an intermittent manner, the engine torque values for driving the respective component shall be determined as average value over an appropriate period, reflecting the actual operating mode based on good engineering judgement and in agreement with the approval authority.
For the purpose of determining whether such a correction is required or not, as well as for deriving the actual values to perform the correction, the power consumption of the following engine components, resulting in the engine torque required for driving these engine components, shall be determined in accordance with Appendix 5 of this Annex:
fan;
electrically powered auxiliaries/equipment necessary for operating the engine system
If an engine of the engine CO2 family, defined in accordance with Appendix 3, is installed in a vehicle equipped with an on-board device for the monitoring and recording of fuel and/or energy consumption and mileage of motor vehicles, in accordance with the requirements referred to in point (b) of Article 5c of Regulation (EC) No 595/2009, the test engine shall be equipped with this on-board device.
In the case of a closed crankcase, the manufacturer shall ensure that the engine's ventilation system does not permit the emission of any crankcase gases into the atmosphere. If the crankcase is of an open type, the emissions shall be measured and added to the tailpipe emissions, following the provisions set out in paragraph 6.10 of Annex 4 to UN Regulation No. 49.
During all testruns the charge air cooling system used on the test bed shall be operated under conditions which are representative for in-vehicle application at reference ambient conditions. The reference ambient conditions are defined as 293 K for air temperature and 101,3 kPa for pressure.
The laboratory charge air cooling for tests according to this Regulation should comply with the provisions specified in paragraph 6.2 of Annex 4 to UN Regulation No. 49.
During all testruns the engine cooling system used on the test bed shall be operated under conditions which are representative for in-vehicle application at reference ambient conditions. The reference ambient conditions are defined as 293 K for air temperature and 101,3 kPa for pressure.
The engine cooling system should be equipped with thermostats according to the manufacturer specification for vehicle installation. If either a non-operational thermostat is installed or no thermostat is used, subpoint (3) shall apply. The setting of the cooling system shall be performed in accordance with subpoint (4).
If no thermostat is used or a non-operational thermostat is installed, the test bed system shall reflect the behavior of the thermostat under all test conditions. The setting of the cooling system shall be performed in accordance with subpoint (4).
The engine coolant flow rate (or alternatively the pressure difference across the engine side of the heat exchanger) and the engine coolant temperature shall be set to a value representative for in-vehicle application at reference ambient conditions when the engine is operated at rated speed and full load with the engine thermostat in fully open position. This setting defines the coolant reference temperature. For all testruns performed for the purpose of certification of one specific engine within one engine CO2-family, the cooling system setting shall not be changed, neither on the engine side nor on the test bed side of the cooling system. The temperature of the test bed side cooling medium shall be kept reasonably constant by good engineering judgement. The cooling medium on the test bed side of the heat exchanger shall not exceed the nominal thermostat opening temperatur downstream of the heat exchanger.
For all testruns performed for the purpose of certification of one specific engine within one engine CO2-family the engine coolant temperature shall be maintained between the nominal value of the thermostat opening temperature declared by the manufacturer and the coolant reference temperature in accordance with subpoint (4) as soon as the engine coolant has reached the declared thermostat opening temperature after engine cold start.
For the WHTC coldstart test performed in accordance with paragraph 4.3.3, the specific initial conditions are specified in paragraphs 7.6.1 and 7.6.2 of Annex 4 to UN Regulation No. 49. If simulation of the thermostat behaviour in accordance with subpoint (3) is applied, there shall be no coolant flow across the heat exchanger as long as the engine coolant has not reached the declared nominal thermostat opening temperature after cold start.
The following requirements shall apply where a WHR system is present on the engine.
The distance between the last after treatment system and the heat exchangers for evaporation of working fluids of WHR systems (boilers), measured in the direction downstream of the engine (LEW), shall be equal to or greater than the maximum distance (LmaxEW) specified by the manufacturer of the WHR system for in-use installation in vehicles.
In the case of WHR systems with turbine(s) in the exhaust gas flow, the distance between the engine outlet and the entry into the turbine (LET) shall be equal or larger than the maximum distance (LmaxET) specified by the manufacturer of the WHR system for in-use installation in vehicles.
For WHR systems operated in a cyclic process using a working fluid:
The total pipe length between evaporator and expander (LHE) shall be equal or longer than defined by the manufacturer as maximum distance for in-use installation in vehicles (LmaxHE);
The total pipe length between expander and condenser (LEC) shall be equal or shorter than defined by the manufacturer as maximum distance for in-use installation in vehicles (LmaxEC);
The total pipe length between condenser and evaporator (LCE) shall be equal or shorter than defined by the manufacturer as maximum distance for in-use installation in vehicles (LmaxCE);
The pressure pcond of the working fluid before entering the condenser shall correspond to the in-use application in vehicles at reference ambient conditions but shall in any case not be lower than the ambient pressure in the test cell minus 5 kPa, unless the manufacturer demonstrates that a lower pressure can be maintained over vehicle lifetime in-use;
The cooling power on the test bed for cooling the WHR condenser shall be limited to a maximum value of Pcool = k × (tcond - 20 °C).
Pcool shall be measured either on the working fluid side or on the test bed coolant side. Where tcond is defined as the condensation temperature (in °C) of the fluid at pcond.
k = f0 + f1 × Vc.
With: Vc is the engine displacement in litres (rounded to 2 places to the right of the decimal point)
f0 = 0,6 kW/K
f1 = 0,05 kW/(K*l);
For cooling the WHR condenser on the test bed either liquid-cooling or air-cooling is allowed. In the case of an air-cooled condenser, the system shall be cooled with the same fan (if applicable) as installed on the vehicle and under the reference ambient conditions stated in subpoint 3.1.6.1. above. In the case of an air-cooled condenser, the limitation for cooling power stated in subpoint (v) above shall apply, where the actual cooling power shall be measured on the working fluid side of the heat condenser. Where the power for driving such a fan is provided from an external power source, the respective actual power consumed by the fan shall be considered as power delivered to the WHR system when determining the net power in accordance with subpoint (f) below.
Other WHR systems taking heat energy from the exhaust or cooling system shall be set up in accordance with the provisions in subpoint (c). The “evaporator” in subpoint (c) refers to the heat exchanger to transfer excess heat to the WHR device. The “expander” in subpoint (c) refers to the device converting the energy.
All pipe diameters of WHR systems shall be equal or smaller than the diameters defined for in-use.
For WHR_mech systems the net mechanical power shall be measured at the rotational engine speed expected at 60 km/h. If different transmission ratios are expected to be used, the rotational speed shall be calculated with the average over these transmission ratios. The mechanical or electrical power generated by a WHR system shall be measured with measurement equipment meeting the respective requirements set out in Table 2.
The net electric power is the sum of the electric power delivered by the WHR system to an external power sink or rechargeable storage, minus the electric power delivered to the WHR system from an external power source or rechargeable storage. The net electric power shall be measured as DC power, i.e. after the conversion from AC to DC.
The net mechanical power is the sum of the mechanical power delivered by the WHR system to an external power sink or rechargeable storage (if applicable), minus the mechanical power delivered to the WHR system from an external power source or rechargeable storage.
All transmission systems for electrical and mechanical power necessary for the vehicle in-use shall be set up for the measurement during the engine testing (e.g. cardan shafts or belt drives for mechanical connection, AC/DC converters and DC/DC voltage transformers). If a transmission system applied in the vehicle is not part of the test set up the net electrical or mechanical power measured shall be decreased accordingly by multiplication by a generic efficiency factor for each separate transmission system. The following generic efficiencies shall be applied for transmission systems not included in the set up:
Type of transmission | Efficiency factor for WHR power
Gear stage | 0,96
Belt drive | 0,92
Chain drive | 0,94
DC/DC converter | 0,95
The respective reference fuel for the engine systems under test shall be selected from the fuel types listed in Table 1 and shall be the same as the reference fuel used for the EC type-approval in accordance with Regulation (EU) No 582/2011. The fuel properties of the reference fuels listed in Table 1 shall be those specified in Annex IX to Commission Regulation (EU) No 582/2011 and for hydrogen in Annex 5 of UN Regulation No 49.
To ensure that the same fuel is used for all testruns performed for the purpose of certification of one specific engine CO2-family no refill of the tank or switch to another tank supplying the engine system shall occur. Exceptionally a refill or switch may be allowed if it can be ensured that the replacement fuel has exactly the same properties as the fuel used before (same production batch).
The NCV for the fuel used shall be determined by two separate measurements in accordance with the respective standards for each fuel type defined in Table 1. The two separate measurements shall be performed by two different labs independent from the manufacturer applying for certification. The lab performing the measurements shall comply with the requirements of ISO/IEC 17025. The approval authority shall ensure that the fuel sample used for determination of the NCV is taken from the batch of fuel used for all testruns.
If the two separate values for the NCV are deviating by more than 440 Joule per gram fuel, the values determined shall be void and the measurement campaign shall be repeated.
The mean value of the two separate NCV that are not deviating by more than 440 Joule per gram fuel shall be documented in MJ/kg rounded to 2 places to the right of the decimal point in accordance with ASTM E 29-06.
For gas and hydrogen fuels the standards for determining the NCV according to Table 1 contain the calculation of the calorific value based on the fuel composition. The gas or hydrogen fuel composition for determining the NCV shall be taken from the analysis of the reference fuel batch used for the certification tests. For the determination of the gas or hydrogen fuel composition used for determining the NCV only one single analysis by a lab independent from the manufacturer applying for certification shall be performed. For gas or hydrogen fuels the NCV shall be determined based on this single analysis instead of a mean value of two separate measurements.
For gas and hydrogen fuels, switches between fuel supply tanks of different production batches are allowed exceptionally. In that case, the NCV of each used fuel batch shall be calculated and the highest of those values shall be documented.
Fuel type / engine type | Reference fuel type | Standard used for determination of NCV
Diesel / CI | B7 or B100 |
at least ASTM D240 or DIN 59100-1
(ASTM D4809 is recommended)
Ethanol / CI | ED95 |
at least ASTM D240 or DIN 59100-1
(ASTM D4809 is recommended)
Petrol / PI | E10 |
at least ASTM D240 or DIN 59100-1
(ASTM D4809 is recommended)
Ethanol / PI | E85 |
at least ASTM D240 or DIN 59100-1
(ASTM D4809 is recommended)
LPG / PI | LPG Fuel B | ASTM 3588 or DIN 51612
Natural gas / PI or Natural Gas / CI | G25 or GR | ISO 6976 or ASTM 3588
Hydrogen / PI or Hydrogen / CI | Hydrogen | ISO 6976 or ASTM 3588
The basic provisions stated in point 3.2 shall be applied for each of the two selected fuels separately.
The lubricating oil for all test runs performed in accordance with this Annex shall be a commercially available oil with unrestricted manufacturer approval under normal in-service conditions as defined in paragraph 4.2 of Annex 8 to UN Regulation No. 49. Lubricants for which the usage is restricted to certain special operation conditions of the engine system or having an unusually short oil change interval shall not be used for the purpose of testruns in accordance with this Annex. The commercially available oil shall not be modified by any means and no additives shall be added.
All testruns performed for the purpose of certification of the CO2 emissions and fuel consumption related properties of one specific engine CO2-family shall be performed with the same type of lubricating oil.
All fuel flows consumed by the whole engine system shall be captured by the fuel flow measurement system. Additional fuel flows not directly supplied to the combustion process in the engine cylinders shall be included in the fuel flow signal for all testruns performed. Additional fuel injectors (e.g. cold start devices) not necessary for the operation of the engine system shall be disconnected from the fuel supply line during all testruns performed.
For dual-fuel engines the fuel flow in accordance with point 3.4 shall be measured for each of the two selected fuels separately.
The measurement equipment shall meet the requirements of paragraph 9 of Annex 4 to UN Regulation No. 49.
Notwithstanding the requirements defined in paragraph 9 of Annex 4 to UN Regulation No. 49, the measurement systems listed in Table 2 shall meet the limits defined in Table 2.
[‘Accuracy’ means the deviation of the analyzer reading from a reference value which is traceable to a national or international standard.] [‘Rise time’ means the difference in time between the 10 percent and 90 percent response of the final analyzer reading (t90 – t10).] [The ‘max calibration’ values shall be 1,1 times the maximum predicted value expected during all testruns for the respective measurement system.]
Linearity |
Measurement system |
Intercept
| xmin × (a1 – 1) + a0 |
Slope
a1
Standard error of estimate SEE |
Coefficient of determination
r2
Accuracy | Rise time
Engine speed | ≤ 0,2 % max calibration | 0,999 - 1,001 | ≤ 0,1 % max calibration | ≥ 0,9985 | 0,2 % of reading or 0,1 % of max. calibration of speed whichever is larger | ≤ 1 s
Engine torque | ≤ 0,5 % max calibration | 0,995 - 1,005 | ≤ 0,5 % max calibration | ≥ 0,995 | 0,6 % of reading or 0,3 % of max. calibration of torque whichever is larger | ≤ 1 s
Fuel mass flow for liquid fuels | ≤ 0,5 % max calibration | 0,995 - 1,005 | ≤ 0,5 % max calibration | ≥ 0,995 | 0,6 % of reading or 0,3 % of max. calibration of flow whichever is larger | ≤ 2 s
Fuel mass flow for gaseous and hydrogen fuels | ≤ 1 % max calibration(3) | 0,99 – 1,01 | ≤ 1 % max calibration (3) | ≥ 0,995 | 1 % of reading or 0,5 % of max. calibration (3) of flow whichever is larger | ≤ 2 s
Electrical Power | ≤ 1 % max calibration | 0,98 - 1,02 | ≤ 2 % max calibration | ≥ 0,990 | n.a. | ≤ 1 s