1.1.
For the purposes of this Annex, the following definitions and abbreviations apply:
‘diagnostic trouble code (“DTC”)’ means a numeric or alphanumeric identifier which identifies or labels a NCM and/ PCM;
‘confirmed and active DTC’ means a DTC that is stored during the time the NCD and/or PCD system concludes that a malfunction exists;
‘NCD engine family’ means a manufacturer's grouping of engines having common methods of monitoring/diagnosing NCMs;
‘NOx Control Diagnostic system (NCD)’ means a system on-board the engine which has the capability of
detecting a NOx Control Malfunction,
identifying the likely cause of NOx control malfunctions by means of information stored in computer memory and/or communicating that information off-board;
‘NOx Control Malfunction (NCM)’ means an attempt to tamper with the NOx control system of an engine or a malfunction affecting that system that might be due to tampering, that is considered by this Regulation as requiring the activation of a warning or an inducement system once detected;
‘Particulate Control Diagnostic system (PCD)’ means a system on-board the engine which has a capability of:
detecting a Particulate Control Malfunction,
identifying the likely cause of particulate control malfunctions by means of information stored in computer memory and/or communicating that information off-board;
‘Particulate Control Malfunction (PCM)’ means an attempt to tamper with the particulate after-treatment system of an engine or a malfunction affecting the particulate after-treatment system that might be due to tampering, that is considered by this Regulation as requiring the activation of a warning once detected;
‘PCD engine family’ means a manufacturer's grouping of engines having common methods of monitoring/diagnosing PCMs;
‘Scan-tool’ means an external test equipment used for off-board communication with the NCD and/or PCD system.
Notwithstanding Article 2(7), where reference is made to ambient temperature in relation to environments other than a laboratory environment, the following provisions shall apply:
1.2.1. For an engine installed in a test-bed, ambient temperature shall be the temperature of the combustion air supplied to the engine, upstream of any part of the engine being tested.
1.2.2. For an engine installed in non-road mobile machinery, ambient temperature shall be the air temperature immediately outside the perimeter of the non-road mobile machinery.
2.1.
This section 2 shall apply for electronically controlled engines of categories NRE, NRG, IWP, IWA, RLL and RLR, complying with ‘Stage V’ emission limits set out in Annex II to Regulation (EU) 2016/1628 and using electronic control to determine both the quantity and timing of injecting fuel or using electronic control to activate, de-activate or modulate the emission control system used to reduce NOx.
2.2.1.
The base emission control strategy shall be designed as to enable the engine, in normal use, to comply with the provisions of this Regulation. Normal use is not restricted to the control conditions as specified in point 2.4.
2.2.2.
Base emission control strategies are, but not limited to, maps or algorithms for controlling:
timing of fuel injection or ignition (engine timing);
exhaust gas recirculation (EGR);
SCR catalyst reagent dosing.
2.2.3.
Any base emission control strategy that can distinguish engine operation between a standardised EU type-approval test and other operating conditions and subsequently reduce the level of emission control when not operating under conditions substantially included in the EU type-approval procedure is prohibited.
2.2.3.1.
Notwithstanding point 2.2.3, in the case of engine (sub-)categories that are not subject to non-road transient test cycles for EU type-approval purposes, the base emission control strategy may identify when transient operating conditions occur and apply the corresponding emission control strategy. In this case, this emission control strategy shall be included in the overview of the base emission control strategy required by point 1.4 of Annex I to Implementing Regulation (EU) 2017/656 and in the confidential information on emission control strategy set out in Appendix 2 to that Annex.
2.2.4.
The manufacturer shall demonstrate to the technical service at the time of the EU type-approval test that the operation of the base emission control strategy complies with the provisions of this section on the basis of the documentation referred to in point 2.6.
2.3.1.
An auxiliary emission control strategy may be activated by an engine or a non-road mobile machinery, provided that the auxiliary emission control strategy:
2.3.1.1. does not permanently reduce the effectiveness of the emission control system;
2.3.1.2. operates only outside the control conditions specified in points 2.4.1, 2.4.2 or 2.4.3 for the purposes defined in point 2.3.5 and only as long as is needed for those purposes, except as permitted by points 2.3.1.3, 2.3.2 and 2.3.4;
2.3.1.3. is activated only exceptionally within the control conditions in points 2.4.1, 2.4.2 or 2.4.3, respectively, has been demonstrated to be necessary for the purposes identified in point 2.3.5 has been approved by the approval authority, and is not activated for longer than is needed for those purposes;
2.3.1.4. ensures a level of performance of the emission control system that is as close as possible to that provided by the base emission control strategy.
2.3.2.
Where the auxiliary emission control strategy is activated during the EU type-approval test, activation shall not be limited to occur outside the control conditions set out in point 2.4, and the purpose shall not be limited to the criteria set out in point 2.3.5.
2.3.3.
Where the auxiliary emission control strategy is not activated during the EU type-approval test, it must be demonstrated that the auxiliary emission control strategy is active only for as long as required for the purposes set out in point 2.3.5.
An auxiliary emission control strategy may be activated on an engine equipped with exhaust gas recirculation (EGR) irrespective of the control conditions in point 2.4 if the ambient temperature is below 275 K (2 °C) and one of the two following criteria is met:
intake manifold temperature is less than or equal to the temperature defined by the following equation: IMTc = PIM/15,75 + 304,4, where: IMTc is the calculated intake manifold temperature, K and PIM is the absolute intake manifold pressure in kPa;
engine coolant temperature is less than or equal to the temperature defined by the following equation: ECTc = PIM/14,004 + 325,8, where: ECTc is the calculated engine coolant temperature, K and PIM is the absolute intake manifold pressure, kPa.
2.3.5.
Except as permitted by point 2.3.2, an auxiliary emission control strategy may solely be activated for the following purposes:
by on-board signals, for protecting the engine (including air-handling device protection) and/or non-road mobile machinery into which the engine is installed from damage;
for operational safety reasons;
for prevention of excessive emissions, during cold start or warming-up, during shut-down;
if used to trade-off the control of one regulated pollutant under specific ambient or operating conditions, for maintaining control of all other regulated pollutants, within the emission limit values that are appropriate for the engine concerned. The purpose is to compensate for naturally occurring phenomena in a manner that provides acceptable control of all emission constituents.
2.3.6.
The manufacturer shall demonstrate to the technical service at the time of the EU type-approval test that the operation of any auxiliary emission control strategy complies with the provisions of this section. The demonstration shall consist of an evaluation of the documentation referred to in point 2.6.
2.3.7.
Any operation of an auxiliary emission control strategy non-compliant with points 2.3.1 to 2.3.5 is prohibited.
The control conditions specify an altitude, ambient temperature and engine coolant range that determines whether auxiliary emission control strategies may generally or only exceptionally be activated in accordance with point 2.3.
The control conditions specify an atmospheric pressure which is measured as absolute atmospheric static pressure (wet or dry) (‘Atmospheric pressure’)
2.4.1.
Control conditions for engines of categories IWP and IWA:
an altitude not exceeding 500 metres (or equivalent atmospheric pressure of 95,5 kPa);
an ambient temperature within the range 275 K to 303 K (2 °C to 30 °C);
the engine coolant temperature above 343 K (70 °C).
2.4.2.
Control conditions for engines of category RLL:
an altitude not exceeding 1000 metres (or equivalent atmospheric pressure of 90 kPa);
an ambient temperature within the range 275 K to 303 K (2 °C to 30 °C);
the engine coolant temperature above 343 K (70 °C).
2.4.3.
Control conditions for engines of categories NRE, NRG and RLR:
the atmospheric pressure greater than or equal to 82,5 kPa;
the ambient temperature within the following range:
equal to or above 266 K (– 7 °C),
less than or equal to the temperature determined by the following equation at the specified atmospheric pressure: Tc = – 0,4514 × (101,3 – Pb) + 311, where: Tc is the calculated ambient air temperature, K and Pb is the atmospheric pressure, kPa;
the engine coolant temperature above 343 K (70 °C).
2.5.
Where the engine inlet air temperature sensor is being used to estimate ambient air temperature the nominal offset between the two measurement points shall be evaluated for an engine type or engine family. Where used, the measured intake air temperature shall be adjusted by an amount equal to the nominal offset to estimate ambient temperature for an installation using the specified engine type or engine family.
The evaluation of the offset shall be made using good engineering judgement based on technical elements (calculations, simulations, experimental results, data etc.) including:
the typical categories of non-road mobile machinery into which the engine type or engine family will be installed; and,
the installation instructions provided to the OEM by the manufacturer.
A copy of the evaluation shall be made available to the approval authority upon request.
The manufacturer shall comply with the documentation requirements laid down in point 1.4 of Part A of Annex I to Implementing Regulation (EU) 2017/656 and Appendix 2 to that Annex.
2.6.1.
The manufacturer shall comply with the documentation requirements laid down in point 1.4 of Part A of Annex I to Implementing Regulation (EU) 2017/656 and Appendix 2 to that Annex.
2.6.2.
The manufacturer shall ensure that all documents used for this purpose are marked with an identification number and date of issue. The manufacturer shall notify to the approval authority whenever the particulars recorded are changed. In this case, it shall issue, either a updated version of the documents concerned where the relevant pages are marked clearly showing the date of revision and the nature of the amendment, or alternatively, a new consolidated version accompanied by an index containing a detailed description and date of each amendment.
3.1.
This section 3 shall apply to electronically controlled engines of categories NRE, NRG, IWP, IWA, RLL and RLR, complying with ‘stage V’ emission limits set out in Annex II to Regulation (EU) 2016/1628 and using electronic control to determine both the quantity and timing of injecting fuel or using electronic control to activate, de-activate or modulate the emission control system used to reduce NOx.
3.2.
The manufacturer shall provide complete information on the functional operational characteristics of the NOx control measures using the documents set out in Annex I to Implementing Regulation (EU) 2017/656.
3.3.
The NOx control strategy shall be operational under all environmental conditions regularly occurring in the territory of the Union, especially at low ambient temperatures.
3.4.
The manufacturer shall demonstrate that the emission of ammonia during the applicable emission test cycle of the EU type-approval procedure, when a reagent is used, does not exceed a mean value of 25 ppm for engines of category RLL and 10 ppm for engines of all other applicable categories.
3.5.
If reagent containers are installed on or connected to a non-road mobile machinery, means for taking a sample of the reagent inside the containers must be included. The sampling point must be easily accessible without requiring the use of any specialised tool or device.
3.6.
In addition to the requirements set out in points 3.2 to 3.5, the following requirements shall apply:
For engines of category NRG the technical requirements set out in Appendix 1;
For engines of category NRE:
the requirements set out in Appendix 2, when the engine is exclusively intended for use in the place of Stage V engines of categories IWP and IWA, in accordance with Article 4(1), point (1)(b) of Regulation (EU) 2016/1628; or
the requirements set out in Appendix 1 for engines not covered by subparagraph (i);
For engines of category IWP, IWA and RLR the technical requirements set out in Appendix 2;
For engines of category RLL the technical requirements set out in Appendix 3
4.1.
This section shall apply to engines of sub-categories subject to a PN limit in accordance with the ‘stage V’ emission limits set out in Annex II to Regulation (EU) 2016/1628 fitted with a particulate after-treatment system In cases where the NOx control system and the particulate control system share the same physical components (e.g. same substrate (SCR on filter), same exhaust gas temperature sensor) the requirements of this section shall not apply to any component or malfunction where, after consideration of a reasoned assessment provided by the manufacturer, the approval authority concludes that a particulate control malfunction within the scope of this section would lead to a corresponding NOx control malfunction within the scope of section 3.
4.2.
The detailed technical requirements relating to particulate pollutant control measures are specified in Appendix 4.
This Appendix sets out the additional requirements to ensure the correct operation of NOx control measures. It includes requirements for engines that rely on the use of a reagent in order to reduce emissions. The EU type-approval shall be made conditional upon the application of the relevant provisions on operator instruction, installation documents, operator warning system, inducement system and reagent freeze protection that are set out in this Appendix.
The engine shall be equipped with a NOx Control Diagnostic system (NCD) able to identify the NOx control malfunctions (NCMs). Any engine covered by this section 2 shall be designed, constructed and installed so as to be capable of meeting these requirements throughout the normal life of the engine under normal conditions of use. In achieving this objective it is acceptable that engines which have been used in excess of the emission durability period as specified in Annex V to Regulation (EU) 2016/1628 show some deterioration in the performance and the sensitivity of the NOx Control Diagnostic system (NCD), such that the thresholds specified in this Annex may be exceeded before the warning and/or inducement systems are activated.
2.1.1.
If the emission control system requires a reagent, the type of reagent, information on concentration when the reagent is in solution, its operational temperature conditions a reference to international standards for composition and quality and other characteristics of that reagent shall be specified by the manufacturer in accordance with Part B of Annex I to Implementing Regulation (EU) 2017/656.
2.1.2.
Detailed written information fully describing the functional operation characteristics of the operator warning system set out in section 4 and of the operator inducement system set out in section 5 shall be provided to the approval authority at the time of EU type-approval.
2.1.3.
The manufacturer shall provide the OEM with documents with instructions on how to install the engine in the non-road mobile machinery in such manner that the engine, its emission control system and the non-road mobile machinery parts, operate in conformity with the requirements of this Appendix. This documentation shall include the detailed technical requirements of the engine (software, hardware, and communication) needed for the correct installation of the engine in the non-road mobile machinery.
2.2.1.
Monitoring for reagent level in the storage tank shall be conducted under all conditions where measurement is technically feasible (for instance, under all conditions when a liquid reagent is not frozen).
2.2.2.
Reagent freeze protection shall apply at ambient temperatures at or below 266 K (– 7 °C).
2.2.3.
All elements of the NOx control diagnostic system other than those listed in points 2.2.1 and 2.2.2 shall, at a minimum, be operational at the applicable control conditions set out in point 2.4 of this Annex for each engine category. The diagnostic system shall remain operational outside of this range where technically possible.
2.3.1.
It is permitted to use a heated or a non-heated reagent tank and dosing system. A heated system shall meet the requirements of points 2.3.2.2 to 2.3.2.2.4. A non-heated system shall meet the requirements of point 2.3.2.3.
2.3.1.1.
The use of a non-heated reagent tank and dosing system shall be indicated in the written instructions to the end-user of the non-road mobile machinery.
2.3.2.1.
If the reagent has frozen, the reagent shall be available for use within a maximum of 70 minutes after the start of the engine at 266 K (– 7 °C) ambient temperature.
A heated system shall be so designed that it meets the performance requirements set out in points 2.3.2 to 2.3.2.2.4 when tested using the procedure defined.
2.3.2.2.1.
The reagent tank and dosing system shall be soaked at 255 K (– 18 °C) for 72 hours or until the reagent becomes solid, whichever occurs first.
2.3.2.2.2.
After the soak period set out in point 2.3.2.2.1, the non-road mobile machinery/engine shall be started and operated at 266 K (– 7 °C) ambient temperature or lower as follows:
10 to 20 minutes idling; followed by
up to 50 minutes at no more than 40 % of rated load.
2.3.2.2.3.
At the conclusion of the test procedure set out in point 2.3.2.2.2, the reagent dosing system shall be fully functional.
2.3.2.2.4.
Evaluation of the design criteria may be performed in a cold chamber test cell using an entire non-road mobile machinery or parts representative of those to be installed on a non-road mobile machinery or based on field tests.
2.3.2.3.
Activation of the operator warning and inducement system for a non-heated system.
2.3.2.3.1.
The operator warning system described in points 4 to 4.9 shall be activated if no reagent dosing occurs at an ambient temperature ≤ 266 K (– 7 °C).
2.3.2.3.2.
The severe inducement system as referred to in point 5.4 shall be activated if no reagent dosing occurs within a maximum of 70 minutes after engine start at an ambient temperature ≤ 266 K (– 7 °C).
2.3.3.1.
The operator warning system described in section 4 shall be activated if no reagent dosing occurs at an ambient temperature ≤ 266 K (– 7 °C).
2.3.3.2.
The severe inducement system described in point 5.4 shall be activated if no reagent dosing occurs within a maximum of 70 minutes after engine start at an ambient temperature ≤ 266 K (– 7 °C).
2.4.1
The NOx Control Diagnostic system (NCD) shall be able to identify the NOx control malfunctions (NCMs) by means of Diagnostic Trouble Codes (DTCs) stored in the computer memory and to communicate that information off-board upon request.
2.4.2.1
The NCD system shall record a DTC for each distinct NOx Control Malfunction (NCM).
2.4.2.2
The NCD system shall conclude within 60 minutes of engine operation whether a detectable malfunction is present. At this time, a ‘confirmed and active’ DTC shall be stored and the warning system be activated according to section 4.
2.4.2.3
In cases where more than 60 minutes running time is required for the monitors to accurately detect and confirm a NCM (e.g. monitors using statistical models or with respect to fluid consumption on the non-road mobile machinery), the approval authority may permit a longer period for monitoring provided the manufacturer justifies the need for the longer period (for example by technical rationale, experimental results, in house experience, etc.).
DTCs shall not be erased by the NCD system itself from the computer memory until the failure related to that DTC has been remedied.
The NCD system may erase all the DTCs upon request of a proprietary scan or maintenance tool that is provided by the engine manufacturer upon request, or using a pass code provided by the engine manufacturer.
2.4.4.
An NCD system shall not be programmed or otherwise designed to partially or totally deactivate based on age of the non-road mobile machinery during the actual life of the engine, nor shall the system contain any algorithm or strategy designed to reduce the effectiveness of the NCD system over time.
2.4.5.
Any reprogrammable computer codes or operating parameters of the NCD system shall be resistant to tampering.
The manufacturer is responsible for determining the composition of an NCD engine family. Grouping engines within an NCD engine family shall be based on good engineering judgment and be subject to approval by the approval authority.
Engines that do not belong to the same engine family may still belong to the same NCD engine family.
An NCD engine family is characterized by basic design parameters that shall be common to engines within the family.
In order that engines are considered to belong to the same NCD engine family, the following list of basic parameters shall be similar:
emission control systems;
methods of NCD monitoring;
criteria for NCD monitoring;
monitoring parameters (e.g. frequency).
These similarities shall be demonstrated by the manufacturer by means of relevant engineering demonstration or other appropriate procedures and subject to the approval of the approval authority.