The measurement of vitellogenin (VTG) is made using an enzyme-linked immunosorbent assay (ELISA) method which was originally developed for fathead minnow VTG (Parks et al., 1999). Currently there are no commercially available antibodies for X. laevis. However, given the wealth of information for this protein and the availability of cost-effective commercial antibody production services, it is reasonable that laboratories can easily develop an ELISA to make this measurement (Olmstead et al., 2009). Also Olmstead et al. (2009) provide a description of the assay as modified for VTG in X. tropicalis, as shown below. The method uses an antibody made against X. tropicalis VTG, but it is known also to work for X. laevis VTG. It should be noted that non-competitive ELISAs can also be used, and that these may have lower detection limits than the method described below.
Preadsorbed 1st Antibody (Ab) serum
Mix 1 part anti-X. tropicalis VTG 1st Ab serum with 2 parts control male plasma and leave at RT for ~ 75 minutes, put on ice for 30 min, centrifuge > 20K x G for 1 hour at 4 oC, remove supernatant, aliquot, store at -20 oC.
2nd Antibody
Goat Anti-Rabbit IgG-HRP conjugate (e.g., Bio-Rad 172-1019)
VTG Standard
purified X. laevis VTG at 3,3 mg/ml.
TMB (3,3',5,5' Tetramethyl-benzidine) (e.g., KPL 50-76-00; or Sigma T0440)
Normal Goat Serum (NGS) (e.g., Chemicon® S26-100ml)
96 well EIA polystyrene microtiter plates (e.g., ICN: 76-381-04, Costar: 53590, Fisher: 07-200-35)
37 oC hybridization oven (or fast equilibrating air incubator) for plates, water bath for tubes
Other common laboratory equipment, chemicals, and supplies.
Coating Buffer (50 mM Carbonate Buffer, pH 9.6):
NaHCO3 | 1,26 g
Na2CO3 | 0,68 g
water | 428 ml
10X PBS (0.1 M phosphate, 1,5 M NaCl):
NaH2PO4·H2O | 0,83 g
Na2HPO4·7 H2O | 20,1 g
NaCl | 71 g
water | 810 ml
Wash Buffer (PBST):
10X PBS | 100 ml
Water | 900 ml
Adjust pH to 7.3 with 1 M HCl, then add 0,5 ml Tween-20
Assay Buffer:
Normal Goat Serum (NGS) | 3,75 ml
Wash Buffer | 146,25 ml
Blood is collected with a heparinised microhematocrit tube and placed on ice. After centrifugation for 3 minutes, the tube is scored, broken open, and the plasma expelled into 0,6 ml microcentrifuge tubes which contain 0,13 units of lyophilised aprotinin. (These tubes are prepared in advance by adding the appropriate amount of aprotinin, freezing, and lyophilising in a speed-vac at low heat until dry.) Store plasma at -80 oC until analysed.
Mix 20 μl of purified VTG with 22 ml of carbonate buffer (final 3 μg/ml). Add 200 μl to each well of a 96-well plate. Cover the plate with adhesive sealing film and allow to incubate at 37 oC for 2 hours (or 4 oC overnight).
Blocking solution is prepared by adding 2 ml of Normal Goat Serum (NGS) to 38 ml of carbonate buffer. Remove coating solution and shake dry. Add 350 μl of the blocking solution to each well. Cover with adhesive sealing film and incubate at 37 oC for 2 hours (or at 4 oC overnight).
5.8 μl of purified VTG standard is mixed with 1,5 ml of assay buffer in a 12 x 75 mm borosilicate disposable glass test tube. This yields 12760 ng/ml. Then a serial dilution is performed by adding 750 μl of the previous dilution to 750 μl of assay buffer to yield final concentrations of 12760, 6380, 3190, 1595, 798, 399, 199, 100, and 50 ng/ml.
Start with a 1:300 (e.g., combine 1 μl plasma with 299 μl of assay buffer) or 1:30 dilution of plasma into assay buffer. If a large amount of VTG is expected, additional or greater dilutions may be needed. Try to keep B/Bo within the range of standards. For samples without appreciable VTG, e.g., control males and females (which are all immature), use the 1:30 dilution. Samples diluted less than this may show unwanted matrix effects.
Additionally, it is recommended to run a positive control sample on each plate. This comes from a pool of plasma containing high induced levels of VTG. The pool is initially diluted in NGS, divided in aliquots and stored at -80 C. For each plate, an aliquot is thawed, diluted further in assay buffer and run similar to a test sample.
The 1st Ab is prepared by making a 1:2000 dilution of preadsorbed 1st Ab serum in assay buffer (e.g., 8 μl to 16 ml of assay buffer). Combine 300 μl of 1st Ab solution with 300 μl of sample/standard in a glass tube. The Bo tube is prepared similarly with 300 μl of assay buffer and 300 μl of antibody. Also, a NSB tube should be prepared using 600 μl of assay buffer only, i.e., no Ab. Cover the tubes with Parafilm and vortex gently to mix. Incubate in a 37 oC water bath for 1 hour.
Just before the 1st Ab incubation is complete, wash the plate. This is done by shaking out the contents and patting dry on absorbent paper. Then fill wells with 350 μl of wash solution, dump out, and pat dry. A multi-channel repeater pipette or plate washer is useful here. The wash step is repeated two more times for a total of three washes.
After the plate has been washed, remove the tubes from the water bath and vortex lightly. Add 200 μl from each sample, standard, Bo, and NSB tube to duplicate wells of the plate. Cover plate with adhesive sealing film and allow to incubate for 1 hour at 37 oC.
At the end of the incubation from the previous step, the plate should be washed three times again, like above. The diluted 2nd Ab is prepared by mixing 2,5 μl of 2nd Ab with 50 ml of assay buffer. Add 200 μl of diluted 2nd Ab to each well, seal like above, and incubate for 1 hour at 37 oC.
After the incubation with the 2nd Ab is complete, wash the plate three times as described earlier. Then add 100 μl of TMB substrate to each well. Allow the reaction to proceed for 10 minutes, preferably out of bright light. Stop the reaction by adding 100 μl of 1 M phosphoric acid. This will change the colour from blue to an intense yellow. Measure the absorbance at 450 nm using a plate reader.
Subtract the average NSB value from all measurements. The B/Bo for each sample and standard is calculated by dividing the absorbance value (B) by the average absorbance of the Bo sample.
Generate a standard curve with the aid of some computer graphing software (e.g., SlidewriteTM or Sigma Plot®) that will extrapolate quantity from B/Bo of sample based on B/Bo of standards. Typically, the amount is plotted on a log scale and the curve has a sigmoid shape. However, it may appear linear when using a narrow range of standards. Correct sample amounts for dilution factor and report as mg VTG/ml of plasma.
Often, particularly in normal males, it will not be clear how to report results from low values. In these cases, the 95 % "Confidence limits" should be used to determine if the value should be reported as zero or as some other number. If the sample result is within the confidence interval of the zero standard (Bo), the result should be reported as zero. The minimum detection level will be the lowest standard which is consistently different from the zero standard; that is, the two confidence intervals don't overlap. For any sample result which is within the confidence limit of the minimum detection level, or above, the calculated value will be reported. If a sample falls between the zero standard and the minimum detection level confidence intervals, one half of the minimum detection level should be reported for the value of that sample.
Olmstead AW, Korte JJ, Woodis KK, Bennett BA, Ostazeski S, Degitz SJ. 2009. Reproductive maturation of the tropical clawed frog: Xenopus tropicalis. General and Comparative Endocrinology 160: 117-123.
Parks LG, Cheek AO, Denslow ND, Heppell SA, McLachlan JA, LeBlanc GA, Sullivan CV. 1999. Fathead minnow (Pimephales promelas) vitellogenin: purification, characterisation and quantitative immunoassay for the detection of estrogenic compounds. Comparative Biochemistry and Physiology Part C: Toxicology & Pharmacology 123: 113-125.