145.1
General
…
SECTION A
TECHNICAL AND ORGANISATIONAL REQUIREMENTS
145.A.10
Scope
This Section establishes the requirements to be met by an organisation to qualify for the issue or continuation of an approval certificate for the maintenance of aircraft and components.
145.A.15
Application for an organisation certificate
An application for a certificate or an amendment to an existing certificate in accordance with this Annex must be made in a form and manner established by the CAA, taking into account the applicable requirements of Annex I (Part-M), Annex Vb (Part-ML) and this Annex.
Applicants for an initial certificate pursuant to this Annex must provide the CAA with:
the results of a pre-audit performed by the organisation against the applicable requirements provided for in Annex I (Part-M), Annex Vb (Part-ML) and this Annex;
documentation demonstrating how they intend to ensure compliance with the requirements of this Regulation.
145.A.20
Terms of Approval
The organisation’s scope of work must be specified in the maintenance organisation exposition (“MOE”) in accordance with point 145.A.70;
The organisation must comply with the terms of approval attached to the organisation certificate issued by the CAA, and with the scope of work specified in the MOE.
145.A.25
Facility requirements
The organisation shall ensure that:
Facilities are provided appropriate for all planned work, ensuring in particular, protection from the weather elements. Specialised workshops and bays are segregated as appropriate, to ensure that environmental and work area contamination is unlikely to occur.
For base maintenance of aircraft, aircraft hangars are both available and large enough to accommodate aircraft on planned base maintenance;
For component maintenance, component workshops are large enough to accommodate the components on planned maintenance.
Office accommodation is provided for the management of the planned work referred to in point (a), and certifying staff so that they can carry out their designated tasks in a manner that contributes to good aircraft maintenance standards.
The working environment including aircraft hangars, component workshops and office accommodation is appropriate for the task carried out and in particular special requirements observed. Unless otherwise dictated by the particular task environment, the working environment must be such that the effectiveness of personnel is not impaired:
temperatures must be maintained such that personnel can carry out required tasks without undue discomfort.
dust and any other airborne contamination are kept to a minimum and not be permitted to reach a level in the work task area where visible aircraft/component surface contamination is evident. Where dust/other airborne contamination results in visible surface contamination, all susceptible systems are sealed until acceptable conditions are re-established.
lighting is such as to ensure each inspection and maintenance task can be carried out in an effective manner.
noise shall not distract personnel from carrying out inspection tasks. Where it is impractical to control the noise source, such personnel are provided with the necessary personal equipment to stop excessive noise causing distraction during inspection tasks.
where a particular maintenance task requires the application of specific environmental conditions different to the foregoing, then such conditions are observed. Specific conditions are identified in the maintenance data.
the working environment for line maintenance is such that the particular maintenance or inspection task can be carried out without undue distraction. Therefore where the working environment deteriorates to an unacceptable level in respect of temperature, moisture, hail, ice, snow, wind, light, dust/other airborne contamination, the particular maintenance or inspection tasks must be suspended until satisfactory conditions are re-established.
Secure storage facilities are provided for components, equipment, tools and material. Storage conditions ensure segregation of serviceable components and material from unserviceable aircraft components, material, equipment and tools. The conditions of storage are in accordance with the manufacturer's instructions to prevent deterioration and damage of stored items. Access to storage facilities is restricted to authorised personnel.
145.A.30
Personnel requirements
The organisation must appoint an accountable manager that has corporate authority to ensure that all maintenance activities of the organisation can be financed and carried out in accordance with Regulation (EU) 2018/1139. The accountable manager must:
ensure that all necessary resources are available to accomplish maintenance in accordance with this Annex, Annex I (Part-M) and Annex Vb (Part-ML), as applicable, to support the organisation certificate;
establish and promote the safety policy specified in point 145.A.200(a)(2);
demonstrate a basic understanding of this Regulation.
The accountable manager—
must nominate a person or group of persons representing the management structure for the maintenance functions and with the responsibility to ensure that the organisation works in accordance with the MOE and approved procedures. It must be made clear in the procedures who deputises for a particular person in the case of lengthy absence of that person;
must nominate a person or group of persons with the responsibility to manage the compliance monitoring function as part of the management system;
must nominate a person or group of persons with the responsibility to manage the development, administration and maintenance of effective safety management processes as part of the management system.
The person or group of persons nominated in accordance with points (b)(1), (2) and (3) must have a responsibility to the accountable manager and direct access to them to keep them properly informed on compliance and safety matters. Additionally, they must be able to demonstrate relevant knowledge, background and satisfactory experience related to aircraft or component maintenance and demonstrate a working knowledge of this Regulation.
The organisation must have a maintenance resource plan to ensure it has sufficient and appropriately qualified staff to plan, perform, supervise, inspect and monitor the organisation’s activities in accordance with the terms of the approval. In addition, the organisation must have a procedure to reassess the work intended to be carried out when the actual staff availability is reduced compared to the planned staffing level for a particular work shift or period.
The organisation must establish and control the competency of the personnel involved in any maintenance, airworthiness reviews, safety management and compliance monitoring in accordance with a procedure and to a standard agreed with the CAA. In addition to the necessary expertise related to the job function, the competency of the personnel must include an understanding of the application of safety management principles, including human factors and human performance issues, which is appropriate to their function and responsibilities in the organisation.
The organisation shall ensure that personnel who carry out or control a continued-airworthiness non-destructive test of aircraft structures or components, or both, are appropriately qualified for the particular non-destructive test in accordance with the European or equivalent standard recognised by the CAA. Personnel who carry out any other specialised task shall be appropriately qualified in accordance with officially recognised standards. By derogation from this point, personnel referred to in point (g), points (h)(1) and (h)(2), qualified in category B1, B3 or L in accordance with Annex III (Part-66), may carry out and/or control colour contrast dye penetrant tests.
Any organisation maintaining aircraft, except where stated otherwise in point (j), shall in the case of aircraft line maintenance, have appropriate aircraft-rated certifying staff qualified as category B1, B2, B2L, B3 and L, as appropriate, in accordance with Annex III (Part-66) and point 145.A.35.
In addition such organisations may also use appropriately task-trained certifying staff holding the privileges set out in points 66.A.20(a)(1) and 66.A.20(a)(3)(ii) and qualified in accordance with Annex III (Part-66) and point 145.A.35 to carry out minor scheduled line maintenance and simple defect rectification. The availability of such certifying staff shall not replace the need for category B1, B2, B2L, B3 and L certifying staff, as appropriate.
Any organisation maintaining aircraft, except where stated otherwise in point (j), shall:
in the case of base maintenance of complex motor-powered aircraft, have appropriate aircraft-type-rated certifying staff, qualified as category C in accordance with Annex III (Part-66) and point 145.A.35. In addition, the organisation shall have sufficient aircraft-type-rated staff qualified as category B1 and B2, as appropriate, in accordance with Annex III (Part-66) and point 145.A.35 to support the category C certifying staff.
Category B1 and B2 support staff shall ensure that all relevant tasks or inspections have been carried out to the required standard before the category C certifying staff issues the certificate of release to service.
The organisation shall maintain a register of any such category B1 and B2 support staff.
The category C certifying staff shall ensure that compliance with point (i) has been met and that all work required by the customer has been accomplished during the particular base maintenance check or work package, and shall also assess the impact of any work not carried out, with a view to either requiring its accomplishment or agreeing with the operator to defer such work to another specified check or time limit.
in the case of base maintenance of aircraft other than complex motor-powered aircraft, have one of the following:
appropriate aircraft-rated certifying staff, qualified as category B1, B2, B2L, B3 and L, as appropriate, in accordance with Annex III (Part-66) and point 145.A.35;
appropriate aircraft-rated certifying staff, qualified in category C and assisted by support staff, as set out in point 145.A.35(a)(i).
Component certifying staff shall be qualified in accordance with Article 5(6) and point 145.A.35.
By derogation to points (g) and (h), in relation to the obligation to comply with Annex III (Part-66), the organisation may use certifying staff and support staff that are qualified in accordance with the following provisions:
For base maintenance carried out at a location outside the United Kingdom, certifying staff and support staff may be qualified in accordance with the national aviation regulations of the State in which the organisation facility is located subject to the conditions specified in Appendix IV to this Annex.
For line maintenance carried out at a line station located outside the United Kingdom, the certifying staff may be qualified, subject to the conditions specified in Appendix IV to this Annex, in accordance with the following alternative conditions:
national aviation regulations of the State in which the line station is located,
national aviation regulation of the State in which the organisation’s principal place of business is located.
For a repetitive pre-flight airworthiness directive which specifically states that the flight crew may carry out such airworthiness directive, the organisation may issue a limited certification authorisation to the pilot on the basis of the flight crew licence held. In that case, the organisation must ensure that the pilot has carried out sufficient practical training ensuring that the pilot can accomplish the airworthiness directive.
If an aircraft is operated away from a supported location, the organisation may issue a limited certification authorisation to the pilot on the basis of the flight crew licence held, subject to being satisfied that the pilot has carried out sufficient practical training ensuring that the pilot can accomplish the specified tasks.
In the following unforeseen cases, where an aircraft is grounded at a location other than the main base where no appropriate certifying staff are available, the organisation contracted to provide maintenance support may issue a one-off certification authorisation:
to one of its employees holding equivalent type authorisations on aircraft of similar technology, construction and systems; or
to any person with not less than five years maintenance experience and holding a valid ICAO aircraft maintenance licence rated for the aircraft type requiring certification provided there is no organisation appropriately approved under this Part at that location and the contracted organisation obtains and holds on file evidence of the experience and the licence of that person.
All such cases as specified in this point must be reported to the CAA within seven days after issuing such certification authorisation. The organisation issuing the one-off authorisation shall ensure that any such maintenance that could affect flight safety is re-checked by an appropriately approved organisation.
If the organisation performs airworthiness reviews and issues the corresponding airworthiness review certificate in accordance with point ML.A.903 of Annex Vb (Part-ML), it shall have airworthiness review staff qualified and authorised in accordance with point 145.A.37
…
…
…
…
…
…
…
…
145.A.35
Certifying staff and support staff
In addition to the requirements of points 145.A.30(g) and (h), the organisation shall ensure that certifying staff and support staff have an adequate understanding of the relevant aircraft or components, or both, to be maintained and of the associated organisation procedures. In the case of certifying staff, this shall be accomplished before the issue or reissue of the certification authorisation.
‘ Support staff ’ means those staff holding an aircraft maintenance licence under Annex III (Part-66) in category B1, B2, B2L, B3 and/or L with the appropriate aircraft ratings, working in a base maintenance environment while not necessarily holding certification privileges.
‘ Relevant aircraft and/or components ’ , means those aircraft or components specified in the particular certification authorisation.
‘ Certification authorisation ’ means the authorisation issued to certifying staff by the organisation and which specifies the fact that those staff may sign certificates of release to service within the limitations stated in such authorisation on behalf of the approved organisation.
Except for the cases listed in points 145.A.30(j) and 66.A.20(a)3(ii), the organisation may only issue a certification authorisation to certifying staff in relation to the basic categories or subcategories and, except for the category A licence, any type rating listed on the aircraft maintenance licence as required by Annex III (Part-66), subject to the licence remaining valid throughout the validity period of the authorisation and to the certifying staff remaining in compliance with Annex III (Part-66).
The organisation shall ensure that all certifying staff and support staff are involved in at least 6 months of actual relevant aircraft or component maintenance experience in any consecutive 2-year period.
For the purpose of this point ‘involved in actual relevant aircraft or component maintenance’ means that the person has worked in an aircraft or component maintenance environment and has either exercised the privileges of the certification authorisation and/or has actually carried out maintenance on at least some of the aircraft type or aircraft group systems specified in the particular certification authorisation.
The organisation must ensure that all certifying staff and support staff receive sufficient recurrent training in each 2 year period to ensure that they have up to date knowledge of relevant technologies, organisation procedures and safety management, including human factor issues.
The organisation must establish a programme for recurrent training for certifying staff and support staff, including a procedure to ensure compliance with the relevant provisions of this point and a procedure to ensure compliance with Annex III (Part-66).
With the exception of the unforeseen cases specified in point 145.A.30(j)(5), the organisation must assess all certifying staff for their competency, qualifications and capability to carry out their intended certifying duties in accordance with a procedure in the MOE prior to the issue or reissue of a certification authorisation under this Annex to such staff.
When the conditions of points (a), (b), (d), (f) and, where applicable, point (c) have been fulfilled by the certifying staff, the organisation shall issue a certification authorisation that clearly specifies the scope and limits of such authorisation. Continued validity of the certification authorisation is dependent upon continued compliance with points (a), (b), (d), and where applicable, (c).
The certification authorisation must be in a style that makes its scope clear to the certifying staff and any authorised person who may require to examine the authorisation. Where codes are used to define scope, the organisation must make a code translation readily available. “Authorised person” means an official of the CAA.
The person or group of persons nominated under point 145.A.30(b)(2) that are responsible for the compliance monitoring function must remain responsible for issuing certification authorisations to certifying staff, but may nominate other persons to effectively issue or revoke certification authorisations in accordance with a procedure in the MOE.
The organisation must provide certifying staff with a copy of their certification authorisation in either written or electronic format.
Certifying staff must produce their certification authorisation to any authorised person within 24 hours of the request.
The minimum age for certifying staff and support staff is 21 years.
The holder of a category A aircraft maintenance licence may only exercise certification privileges on a specific aircraft type following the satisfactory completion of the relevant category A aircraft task training carried out by an organisation appropriately approved in accordance with Annex II (Part-145) or Annex IV (Part-147). This training must include practical hands-on training and theoretical training as appropriate for each task authorised. Satisfactory completion of training must be demonstrated by an examination or by workplace assessment carried out by the organisation.
The holder of a category B2 aircraft maintenance licence may only exercise the certification privileges described in point 66.A.20(a)(3)(ii) of Annex III (Part-66) following the satisfactory completion of:
the relevant category A aircraft task training; and
6 months of proven practical experience covering the scope of the authorisation to be issued.
The task training referred to in point (n)(i) must include practical hands-on training and theoretical training as appropriate for each task authorised. Satisfactory completion of training must be demonstrated by an examination or by workplace assessment. Task training and examination or assessment must be carried out by the maintenance organisation issuing the certifying staff authorisation. The practical experience must also be obtained within that maintenance organisation.
145.A.36
Records of airworthiness review staff
…
145.A.37
Airworthiness review staff
In order to be approved to carry out airworthiness reviews and to issue the corresponding airworthiness review certificates (ARC) for aircraft covered by Annex Vb (Part-ML), the organisation must have airworthiness review staff that comply with all of the following requirements:
they have acquired experience in continuing airworthiness of at least 1 year for sailplanes and balloons and of at least 3 years for all other aircraft;
they hold a certifying staff authorisation for the corresponding aircraft;
they have acquired knowledge of Annex I (Part-M), Subpart C, or of Annex Vb (Part-ML), Subpart C;
they have acquired knowledge of the procedures of the maintenance organisation relevant to the airworthiness review and issue of the airworthiness review certificate.
Before the organisation issues an airworthiness review authorisation to a candidate, that candidate must perform an airworthiness review under the supervision of the CAA or under the supervision of a person that is already authorised as airworthiness review staff by the organisation. If this airworthiness review under supervision is satisfactory, the CAA may formally accept that candidate to become airworthiness review staff.
The organisation must ensure that the airworthiness review staff can demonstrate appropriate recent continuing airworthiness experience.
145.A.40
Equipment and tools
The organisation shall have available and use the necessary equipment and tools to perform the approved scope of work.
Where the manufacturer specifies a particular tool or equipment, the organisation shall use that tool or equipment, unless the use of alternative tooling or equipment is agreed by the CAA via procedures specified in the exposition.
Equipment and tools must be permanently available, except in the case of any tool or equipment that is so infrequently used that its permanent availability is not necessary. Such cases shall be detailed in an exposition procedure.
An organisation approved for base maintenance shall have sufficient aircraft access equipment and inspection platforms/docking as required for the proper inspection of the aircraft.
The organisation shall ensure that all tools, equipment and particularly test equipment, as appropriate, are controlled and calibrated according to an officially recognised standard at a frequency to ensure serviceability and accuracy. Records of such calibrations and traceability to the standard used shall be kept by the organisation.
145.A.42
Components
Classification of components. All components shall be classified into the following categories:
Components which are in a satisfactory condition, released on a CAA Form 1 or equivalent and marked in accordance with Subpart Q of the Annex I (Part 21) to Regulation (EU) No 748/2012, unless otherwise specified in point 21.A.307 of Annex I (Part 21) to Regulation (EU) No 748/2012 , in point M.A.502 of Annex I (Part-M), in point ML.A.502 of Annex Vb (Part-ML), or in this Annex (Part-145).
Unserviceable components which shall be maintained in accordance with this Regulation.
Components categorised as unsalvageable because they have reached their mandatory life limitation or contain a non-repairable defect.