11 ANNEX X Test procedure for the verification of the performance of the back-up power supply, Regulation (EU) 2017/79

In forcesince 17 Nov 2025

The purpose of this test is to make sure that the eCall in-vehicle system or eCall STU is capable to communicate for the period specified in point 2.

The eCall system or eCall STU shall be operable for a period of at least 5 minutes in voice communication mode followed by 60 minutes in call-back mode (idle mode, registered in the network) followed by another period of at least 5 minutes in voice communication mode.

The following verification test shall be performed on an eCall STU that has been subjected to the high-severity deceleration test according to Annex I.

If the eCall STU does not include the microphone(s) and speaker(s) for the eCall system, then representative microphone(s) and speaker(s) shall be added to the test setup in order to execute the test from this Annex.

3.1.1. Perform an eCall by applying a manual trigger of the system.

3.1.2. Verify that a call was established with the PSAP test point by a record of the PSAP test point showing that it received the call or by a successful voice connection to the PSAP test point.

3.1.3. Disconnect the main power source.

3.1.4. Read out any text for at least 5 minutes at the PSAP test point.

3.1.5. Clear down the eCall using the appropriate PSAP test point command (e.g. hang up).

3.1.6. Wait for 56 minutes after the call was ended.

3.1.7. Initiate a call from the PSAP test point to the eCall in-vehicle system.

3.1.8. If the call is automatically accepted, read out any text for at least 5 minutes at the PSAP test point, otherwise the test is finished.

3.2.1. The requirement is determined to have been passed if the eCall STU is capable to communicate for the required period, as specified in point 2.

3.2.2. The incapacity of the 112-based eCall in-vehicle system to communicate for the period referred to in point 2 constitutes a failure.