3 ANNEX III Reporting template that Member States shall use for reporting to the Commission pursuant to Article 6(2) of Directive (EU) 2024/1275 and Article 6 of this Regulation, Regulation (EU) 2025/2273

In forcesince 30 Jun 2025

1.1. Report synthetic information on the reference buildings for all building categories and how they are representative of the building stock by using Table 1 (existing buildings) and Table 2 (new buildings). Additional information may be added in an annex or in the text accompanying the relevant tables.

1.2. Give the definition of the reference floor area used in your country and how it is calculated.

1.3. List the selection criteria used to define each reference building (both new and existing): e.g. statistical analysis based on use, age, geometry, climate zones, cost structures, construction material, etc., introducing also the indoor and outdoor climatic conditions, and geographic location.

1.4. If a Member State has reduced the number of reference buildings by using a reference building serving several building categories, it shall justify this approach on the basis of an analysis showing that the reference building is representative of the building stock for all the categories covered.

1.5. Indicate whether your reference building is an example building, virtual building, etc.

1.6. Indicate the underlying dataset for the national building stock.

1.7. All buildings and subcategories should be listed in Tables 1 and 2. When, in case of minor variations (e.g. only one parameter is changed), Member States decide not to include every reference building considered, they are required to include the number of variations considered for each category in the relevant column.

1.8. Table 3 shall be filled for each reference building in all its parts, unless the introduction of a specific parameter is not relevant for the reporting of the calculation. Approaches can differ between new and existing reference buildings. For new buildings, on the basis of how the calculations are set, only the basic characteristics of each reference building need to be reported in Table 3, while the results of measures/packages/variants can be reported in Table 5. The ‘Description’ column can be used to provide explanations and comments. In addition, Member States are recommended to add parameters that they deem relevant to report the calculations, including voluntary elements that they decided to include in the calculations.

1.9. The first sections of Table 3 (‘Calculation’, ‘Climatic Conditions’, ‘Building setpoints and schedules’) are general and do not need to be reported for each reference building, if they do not change. In such a case, these sections may also be reported separately with a clear indication of the reference buildings that they apply to.

1.10. If variations of the same reference building are analysed and if the same reference building is calculated in different climatic zones of the national territory, the ‘Quantity’ column in Table 3 may be replicated and filled only with the relevant information, without the need to reproduce the whole table.

[Reference floor area, S/V (surface to volume), orientation, area of north/west/south/east (N/W/S/E) façade.] [Period of construction/age (if appropriate), construction material, typical air tightness (qualitative), use pattern (if appropriate).] [Technical building systems; U-values of building elements; area, U-value and g-value of windows; shading; etc.] [All EPB uses included: heating, domestic hot water (DHW), ventilation, cooling, built-in lighting and auxiliary energy.]

For existing buildings | Building geometry | Shares of window area on the building envelope and windows with no solar access | Floor area m2 as used in building code | Description of the building | Description of the average building technology | Average total primary energy performance kWh/m2y (prior to investment) | Component level requirements (typical value) (where relevant) | Total number of variations (if relevant)

(1)

Single family buildings and subcategories

Subcategory 1 | | | | | | | |

Subcategory 2 etc. | | | | | | | |

(2)

Apartment blocks and multifamily buildings and subcategories

(3)

Office buildings and subcategories

(4)

Other non-residential building categories

[Reference floor area, S/V, area of N/W/S/E façade. To note: the orientation of the building can already constitute an energy efficiency measure in itself in the case of new buildings.] [Other parameters can be used, where relevant.]

For new buildings | Building geometry | Shares of window area on the building envelope and windows with no solar access | Floor area m2 as used in building code | Description of the building | Description of the average building technology | Average total primary energy performance kWh/m2y (prior to investment) | Component level requirements (where relevant) | Total number of variations (if relevant)

(1)

Single family buildings and subcategories

Subcategory 1 | | | | | | | |

Subcategory 2 etc. | | | | | | | |

(2)

Apartment blocks and multifamily buildings and subcategories

(3)

Office buildings and subcategories

(4)

Other non-residential building categories

Quantity | Unit | Description

Reference Building | | - |

Where relevant, provide a description of the variants, if variants of the same reference buildings are reported by duplicating the ‘quantity’ column.

Specify whether the building is in a rural, urban or metropolitan area.

Calculation | Method and tool (s) | | - | Short description of the calculation method adopted (e.g. with reference to ISO 52016-1) and comment on the calculation tool(s) used

Calculation period | | years | Where relevant, distinguish per building type.

Primary energy conversion factors | Energy carrier 1 | Total | | - |

Values of primary energy factors or weighting factors (per energy carrier) used for the calculation.

Factors to be differentiated by total, renewable and non-renewable share.

Specify possible correction factors considered. The choices made and data sources shall be reported according to EN 17423 or any superseding document.

Non-renewable | | -

Renewable | | -

GHG-emission factors | Energy carrier 1 | | g/kWh | Values of GHG emission factors (per energy carrier) used for the calculation

Air pollutant emissions factor | Energy carrier 1 | PM2,5 | | g/kWh | Values of pollutant emission factors (per energy carrier) used for the calculation. Add rows if pollutants other than PM2,5 and NOx are considered. Where relevant, indicate if current factors or the average over the evaluation period is assumed

NOx |

Climate condition | Location | | - | Name of the city with indication of latitude and longitude

Climate zone | | | According to national climatic zone classification, if available

Heating degree days | | HDD | HDD and CDD can be evaluated according to EN ISO 15927-6, specifying the calculation period. Indicate whether climate data and their future changes according to best available climate projections, including heat and cold waves were taken into account and the sources of projections data

Cooling degree days | | CDD

Source of climatic dataset | | - | Provide references on climatic dataset used for the calculation

Building setpoints and schedules | Temperature setpoint | Winter | | °C | Indoor operative temperature or other relevant parameters set in line with IEQ requirements

Summer | | °C

Humidity setpoint | Winter | | % | Indoor relative humidity or other relevant parameters set in line with IEQ requirements

Summer | | %

Operation schedules and controls | Occupancy | | - |

Provide comments or references (EN or national standards, etc.) on the schedules used for the calculation.

Schedules should be appropriately differentiated per building type and do not need to be replicated for each reference building.

Lighting | | -

Appliances | | -

Ventilation | | -

Heating system | | -

Cooling system | | -

Building geometry | Volume (or Length × Width × Height) | |

m3

(or m × m × m)

Related to the heated/conditioned air volume (e.g. in line with ISO 52016-1) and, where relevant, considering as ‘length’ the horizontal dimension of the façade south-oriented

Number of floors | | - | Where relevant

S/V (surface-to-volume) ratio | | m2/m3 | -

Ratio of window area over total building envelope area |

S / E / N / W

and/or total

% | Report specifying by façade orientation or, alternatively, report the total ratio

Orientation | | ° | Azimuth angle of the south façade (deviation from the south direction of the ‘south’ oriented façade)

Internal gains | Building utilisation | | - | According to the building categories proposed in Annex 1 to Directive (EU) 2024/1275

Average thermal gain from occupants | | W/m2 | -

Specific electric power of the lighting system | | W/m2 | Total electric power of the complete lighting system of the conditioned rooms (all lamps + control equipment of the lighting system), where relevant

Specific electric power of electric equipment | | W/m2 | Where relevant

Building elements | Average U-value of walls | | W/m2K | Weighted U-value of all walls: U_wall = (U_wall_1 × A_wall_1 + U_wall_2 × A_wall_2 + … + U_wall_n × A_wall_n)/(A_wall_1 + A_wall_2 + … + A_wall_n); where: U_wall_i = Uvalue of wall type i; A_wall_i = total surface of wall type i

Average U-value of roof | | W/m2K | Similar to walls

Average U-value of basement | | W/m2K | Similar to walls

Average U-value of windows | | W/m2K | Similar to walls; it should take into account the thermal bridge due to the frame and dividers (e.g. according to EN ISO 10077-1)

Thermal bridges | Total length | | m | -

Average linear thermal transmittance | | W/mK | -

Thermal capacity per unit area | External walls | | J/m2K | To be evaluated according to the relevant standards, such as EN ISO 13786

Internal walls | | J/m2K

Slabs | | J/m2K

Type of shading systems | | - | E.g. solar blind, roll-up shutter, curtain, etc.

Average g-value of | Glazing | | - | Total solar energy transmittance of glazing (for radiation perpendicular to the glazing): weighted value according to the area of different transparent elements

Glazing + shading | | - | Total solar energy transmittance for glazing and external solar protection devices to be evaluated according to the relevant standards, such as EN ISO 52022-1

Infiltration rate (air changes per hour) | | 1/h | E.g. calculated for a pressure difference inside/outside of 50 Pa

Building systems | Ventilation system | Ventilation rate | | l/s | To be evaluated according to the relevant standards, such as EN 16798

Heat recovery efficiency | | %

Efficiencies of heating system | Generation | | % | To be evaluated according to relevant standards, such as EN 15316-1, EN 15316-2-1, EN 15316-4-1, EN 15316-4-2, EN 15120, EN 14825, EN 14511, and subsequent revisions

Distribution | | %

Emission | | %

Control | | %

Efficiencies of air-conditioning system | Generation | | % | To be evaluated according to relevant standards, such as EN 14825, EN 16798-13, EN 14511, EN 15120, and subsequent revisions

Distribution | | %

Emission | | %

Control | | %

Efficiencies of DHW system | Generation | | % | To be evaluated according to the relevant standards

Control | | %

Building energy need | (Thermal) energy contribution of main passive strategies implemented | (1) ... | | kWh/(m2y) | E.g. solar greenhouse, natural ventilation, daylighting, etc., where relevant

(2)

... | | kWh/(m2y)

(3)

... | | kWh/(m2y)

Energy need for heating | | kWh/(m2y) | Heat to be delivered to or extracted from a conditioned space to maintain the intended temperature conditions during a given period of time

Energy need for cooling | | kWh/(m2y)

Energy need for DHW | | kWh/(m2y) | Heat to be delivered to the needed amount of DHW to raise its temperature from the cold network temperature to the prefixed delivery temperature at the delivery point

Energy need for other (humidification, dehumidification) | | kWh/(m2y) | Latent heat in the water vapour to be delivered to or extracted from a conditioned space by a technical building system to maintain a specified minimum or maximum humidity within the space (if applicable)

Building energy use | Energy use for heating | | kWh/(m2y) | Energy input to the heating/cooling/DHW systems to satisfy the energy needs for heating, cooling and DHW (e.g. in line with ISO 52000-1:2017)

Energy use for cooling | | kWh/(m2y)

Energy use for DHW | | kWh/(m2y)

Energy use for ventilation | | kWh/(m2y) | Electrical energy input to the ventilation system for air transport and heat recovery (not including the energy input for preheating or precooling the air) and energy input to the humidification systems to satisfy the need for humidification

Energy use for built-in lighting | | kWh/(m2y) | Electrical energy input to the lighting system, where relevant

Energy use for other on-site uses | | kWh/(m2y) | Electrical energy input to on-site uses other than EPB services, including appliances, miscellaneous and ancillary loads, or electro-mobility recharging points. Specify where relevant

Renewable energy generation at the building site | Thermal energy from renewable energy sources (e.g. thermal solar collectors, ambient heat) | | kWh/(m2y) |

On-site renewable energy production should be calculated by using either sub-hourly, hourly modelling or monthly modelling adjusted e.g. through considering monthly correction factors.

Specify the different sources considered, where relevant.

Specify, where considered in the calculation, whether the renewable electricity is also considered for other on-site uses (in line with Article 2(60) of Directive (EU) 2024/1275).

The energy from on-site generators based on bioenergy should not be considered here, since the primary energy carrier (e.g. solid biomass, biogases or biofuels) is supplied from outside building premises.

Electrical energy generated in the building and self-consumed on-site for EPB uses | | kWh/(m2y)

Energy generated in the building and exported to the market | | kWh/(m2y)

Other energy generation at the building site | | kWh/(m2y) | Only where relevant

Delivered energy | Delivered energy to the building from nearby or distant sources | Electricity | | kWh/(m2y) | Energy, expressed per energy carrier, supplied to the technical building systems through the system boundary, to satisfy the uses taken into account (heating, cooling, ventilation, domestic hot water, lighting, etc.)

Fossil fuel (specify) | | kWh/(m2y)

Other (specify: biomass, district heating/ cooling...) | | kWh/(m2y)

Primary energy | Total primary energy | | kWh/(m2y) | Exported energy (e.g. on-site generated renewable electricity not accounted for self-use or other on-site, non-EPB, uses) may be deducted from the total primary energy use.

Non-renewable primary energy | | kWh/(m2y) | -

Renewable primary energy | | kWh/(m2y) | -

Emissions | Greenhouse gas emissions | | kgCO2eq/(m2y) | Operational emissions

PM2,5 emissions | | kgPM2,5/ (m2y) | If other pollutants are considered in the calculation, add the results

NOx emissions | | kgNOx/ (m2y)

Fill out one table for each reference building.

2.1. Report in table format the characteristics of selected measures/packages/variants that are applied for the cost-optimal calculation. Start with the most common technologies and solutions and then move towards the more innovative ones. If there is evidence from previous calculations that measures are far from being cost-optimal, no table has to be filled in but this should be reported separately to the Commission. The format below can be used, but note that the examples listed are purely illustrative.

2.2. For renovations and new buildings, minimum IEQ levels need to be ensured pursuant to Article 7(6) and Article 8(3) of the Directive (EU) 2024/1275. These requirements need to be considered when defining the measures/packages.

2.3. Where relevant, Member States can decide to report two separate tables for listing measure/package/variant for new and existing buildings. Where relevant, Member States can add a column to specify the reference building or subcategory the measure/package/variant refers to.

2.4. More measures can be grouped into packages and, where relevant, these should also be reported in Table 4.

2.5. Reporting can be limited to the most important measures/packages but it should be indicated how many calculations have been carried out in total.

Code | Measure | Reference case | Variation 1 | Variation 2 | Etc.

(e.g. RI – so variations are RI.1… RI.n) | Roof insulation | | | |

Wall insulation | | | |

Windows | 5,7 W/m2K (description) | 2,7 W/m2K (description) | 1,9 W/m2K (description) |

Share of window area of total building envelope | | | |

Building-related measures (thermal mass etc.) | | | |

Heating system | | | |

DHW | | | |

Ventilation system | | | |

Space cooling system | | | |

Measures based on renewable energy sources (on site) | | | |

Change of energy carrier | | | |

etc. | | | |

The listing of measures is purely illustrative, but the main information in the table (description of the variation/s, indicator of performance) must be maintained.

For the building envelope, thermal transmittance in W/m2K could be used;

For systems, efficiency could be used;

For ventilation systems, air renewal rates in l/s could be used;

Several levels of improvements can be selected, including performance requirements in force (for example: different thermal transmittance values for windows).

3.1.1. The calculation procedure for the energy performance assessment that is applied to the reference buildings and to the adopted measures/packages/variants is reported as part of Table 3 (sections ‘Calculation’, ‘Climatic Conditions’, ‘Building setpoints and schedules’). This does not need to be done for each reference building, unless necessary.

3.1.2. Give references to relevant legislation, regulation, standards and norms.

3.1.3. Fill in the calculation period, the calculation interval (annual, monthly or daily) and the used climate data per reference building.

Reporting can be limited to the most important measures/packages/variants but it should be indicated how many calculations have been carried out in total.

3.2.1. Report the results of the energy performance calculation for each measure/package/variant for each reference building differentiated to at least energy need for heating and cooling, energy use, delivered energy and total primary energy use (including renewable and non-renewable parts). Include also the energy savings.

3.2.2. Member States are free to add rows to include relevant information that need to be reported by mirroring the information provided for the reference building in Table 3.

Measure/package/variant (as described in Table 4) | Code | | | | | …

Energy needs | For heating | | | | |

For cooling | | | | |

Final energy use | Heating | | | | |

Cooling | | | | |

Ventilation | | | | |

DHW | | | | |

Built-in lighting | | | | |

Other (specify) | | | | |

Delivered energy specified by carrier | ec1 | | | | |

… | | | | |

Renewable energy generation at the building site | Energy generated in the building and used on-site for self-use | | | | |

Energy generated in the building and used on-site for other on-site uses | | | | |

Exported energy | | | | |

Primary energy use in kWh/m2y | Total | | | | |

Non-renewable | | | | |

Renewable | | | | |

GHG emission performance in kgCO2/m2y | | | | |

PM2,5 emission performance in kgPM2,5/m2y | | | | |

NOx emission performance in kgNOx/m2y | | | | |

Primary energy reduction compared to the reference building | | | | |

GHG emission reduction compared to the reference building | | | | |

PM2,5 emission reduction compared to the reference building | | | | |

NOx emission reduction compared to the reference building | | | | |

Additional optional indicators | | | | |

Fill out one table for each reference building.

If there is evidence from previous calculations that measures are far from being cost-optimal, no table has to be filled in but this should be reported separately to the Commission.

4.1. Calculate the global cost for each measure/package/variant using the following tables, referring to low, medium or high (energy price) scenario. The cost calculation for the reference building shall be put at 100 %.

4.2. Report the applied discount rate for the financial and the macroeconomic calculation and the result of the underlying sensitivity analysis on at least two different interest rates each.

4.3. Report the input parameters used for the calculation of the global cost (e.g. labour cost, cost of the technology, cost of pollutant per kg of emission), including relevant sources and assumptions.

4.4. Report the applied energy and carbon price development and the source.

4.5. Include in a separate table the input parameters for the other costs eventually included, where relevant (e.g. health impacts, impacts on GDP).

4.6. Perform a calculation on the sensitivity analysis for the main costs and for energy costs and the applied discount rate for both the macroeconomic and the financial calculation. For each variation of cost use a separate table like the Table below.

Measure/package/variant as given in Table 5 | Code | | | | | …

Initial investment cost (referred to starting year) | | | | |

Annual costs | Annual maintenance cost | | | | |

Operational cost | | | | |

… | | | | |

Energy cost by fuel with the medium energy price scenario | Fuel1 | | | | |

…

Cost of operational greenhouse gas emissions (only for the macroeconomic calculation) | | | | |

Residual value | | | | |

Discount rate (different rates for the macroeconomic and financial calculations) | | | | |

Estimated economic lifetime | | | | |

Waste management costs (when applicable) | | | | |

Environmental and health externalities of energy use (only for the macroeconomic calculation) | Cost of PM2,5 emissions | | | | |

Cost of NOx emissions | | | | |

Other costs, where applicable | | | | |

Global cost calculated | | | | |

Fill out the table for each reference building using it once for the macroeconomic calculation and once for the financial calculation. Insert the cost data in the relevant currency and specify the currency used in the table.

5.1. Report the economic optimal energy performance level in total primary energy (kWh/m2 year) and, if a system level approach is followed for defining minimum energy performance requirements, in the relevant unit (e.g. W/m2K for the U value, % for system efficiency) for each case in relation to the reference buildings indicating whether it is the cost-optimal levels calculated at macroeconomic or financial level.

5.2. Member States are encouraged to use other indicators to complement total primary energy when setting minimum energy performance requirements, depending on national, regional, or local conditions, such as the emission performance.