Art. 2 Regulation (EU) 2025/2273

Definitions

In forcesince 30 Jun 2025

In addition to the definitions set out in Article 2 of Directive (EU) 2024/1275, the following definitions shall apply for the purposes of this Regulation:

(1)

‘global cost’ means the sum of the present values of the initial investment costs, running costs, replacement costs (referred to the starting year), waste management costs, if applicable and, for the purposes of the calculation at macroeconomic level, it includes costs of greenhouse gas emissions as well as health and environmental externalities of energy use;

(2)

‘initial investment cost’ means all costs incurred up to the point when the building or building element is delivered to the customer, ready to use. Those costs include design, purchase of building elements, connection to suppliers, installation and commissioning processes;

(3)

‘energy cost’ means the annual energy costs, including energy price, capacity tariffs and grid tariffs, and national taxes, taking into account the cost of greenhouse gas allowances.

(4)

‘operational cost’ means all costs linked to the operation of the building, including annual costs for insurance, utility charges and other standing charges and taxes;

(5)

‘maintenance cost’ means the annual costs for measures to preserve and restore the desired quality of the building or building element including annual costs for inspection, cleaning, adjustments, repair and consumable items;

(6)

‘running cost’ means the annual maintenance, operational and energy costs;

(7)

‘waste management cost’ means the cost of a building or building element at the end of its life, including dismantling, removal of building elements that have not yet come to the end of their lifetime, transport, disposal and recycling;

(8)

‘replacement cost’ means a substitute investment for a building element, in accordance with the estimated economic life cycle during the calculation period;

(9)

‘annual cost’ means the sum of running costs and replacement costs paid per year;

(10)

‘cost of greenhouse gas emissions’ means the monetary value of environmental damage caused by CO2 emissions, related to the energy consumption in buildings;

(11)

‘environmental and health externalities of energy use’ means, but is not limited to, the monetary value of the health and environmental damage caused by emissions of PM2,5 and NOx, related to the energy consumption in buildings;

(12)

‘reference building’ means a hypothetical or real building that represents the typical building geometry and systems, the typical energy performance for both building envelope and systems, the typical functionality and typical cost structure in the Member State, and that is representative of climatic conditions and geographic location;

(13)

‘discount rate’ means a specific value to compare the value of money at different times expressed in real terms;

(14)

‘discount factor’ means a multiplicative number used to convert a cash flow occurring at a given point in time to its equivalent value at the starting point, which is derived from the discount rate;

(15)

‘starting year’ means the year from which the calculation period is determined;

(16)

‘calculation period’ means the time period considered for the calculation, usually expressed in years;

(17)

‘residual value of a building’ means the sum of the residual values of building elements at the end of the calculation period;

(18)

‘price development’ means the development over time of prices for energy, products, building systems, services, labour, maintenance and other costs which can be different from the inflation rate;

(19)

‘energy efficiency measure’ means a change to a building or building element resulting in a reduction of the building’s final energy use;

(20)

‘package’ means a set of energy efficiency measures or measures based on renewable energy sources applied to a reference building, or both;

(21)

‘variant’ means the global result and description of a full set of measures or packages applied to a building that can be made up of a combination of measures on the building envelope, passive techniques, measures on building systems or measures based on renewable energy sources, or a combination of those measures;

(22)

‘subcategories of buildings’ means categories of building types that are more disaggregated according to size, age, construction material, use pattern, climatic zone or according to criteria other than those established by point 6 of Annex I to Directive (EU) 2024/1275, for which reference buildings are generally established;