This Annex provides for additional requirements and specific adaptations to the requirements set out in this Regulation which shall apply to certain types of veterinary medicinal products.
Unless stated otherwise, the requirements contained in this Annex shall apply in addition to the requirements provided for in the Regulation. In case of conflict, the specific requirements set out in this Annex shall prevail.
1. Taking into account the variability of herbal materials, the control of herbal materials (herbal substances and herbal preparations) used in the manufacture of veterinary medicinal products is particularly important.
2. Herbal materials used in the manufacture of veterinary medicinal products shall be of suitable quality. The selection of seeds, cultivation and harvesting conditions are important aspects of the quality of the herbal substance that can influence the consistency of the finished product.
3. Table 1 illustrates the application of good practices in connection with the manufacture of veterinary medicinal products.
[Manufacturers shall carry out these steps in accordance with the marketing authorisation. For initial steps that take place in the field, as justified in the marketing authorisation, the standards of good agricultural and collection practice for starting materials of herbal origin (GACP) shall apply. Good manufacturing practice shall apply to further cutting and drying steps.] [Regarding the expression from plants and distillation, if it is necessary for these activities to be an integral part of harvesting to maintain the quality of the product within the approved specifications, it is acceptable that they are performed in the field, provided that the cultivation is in compliance with GACP. This approach may only be accepted in exceptional cases and provided that it is agreed in the relevant marketing authorisation. For activities carried out in the field, appropriate documentation, control and validation according to good manufacturing principles shall be assured.]
Activity | Good agricultural and collection practice | GMP for active substances used in the manufacture of veterinary medicinal products or GMP for veterinary medicinal products, as applicable | GMP for veterinary medicinal products
Cultivation, collection and harvesting of plants, algae, fungi and lichens, and collection of exudates | Applicable | |
Cutting, and drying of plants, algae, fungi, lichens and exudates | Applicable | Applicable |
Expression from plants and distillation | | Applicable |
Comminution, processing of exudates, extraction from plants, fractionation, purification, concentration or fermentation of herbal substances | | Applicable |
Further processing into a dosage form, including packaging as finished veterinary medicinal product | | | Applicable
4. The herbal materials used in the manufacture of veterinary medicinal products shall comply with the following:
Specifications shall be set in compliance with the marketing authorisation and shall include:
the binomial scientific name of plant (genus, species, subspecies/variety and author (e.g. Linnaeus); other relevant information such as the cultivar name and the chemotype shall also be provided, as appropriate;
details of the source of the plant (country or region of origin, and where applicable, cultivation, time of harvesting, collection procedures, possible pesticides used, possible radioactive contamination, etc.);
which part(s) of the plant is/are used;
when a dried plant is used, the drying system shall be specified;
a description of the herbal substance and its macro and microscopic examination;
suitable identification tests including, where appropriate, identification tests for constituents with known therapeutic activity or markers. Specific distinctive tests are required where an herbal substance is liable to be adulterated/ substituted. A reference authentic specimen shall be available for identification purposes;
the water content for herbal substances, which is to be determined in accordance with the European Pharmacopoeia;
assay of constituents of known therapeutic activity or, where appropriate, of markers;
methods to determine a possible pesticide contamination and the accepted limits, in accordance with European Pharmacopoeia methods or, in the absence thereof, with an appropriate validated method, unless otherwise justified;
tests to determine fungal and/or microbial contamination, including aflatoxins, other mycotoxins, pest-infestations and limits accepted, as appropriate;
tests for toxic metals and for likely contaminants and adulterants, as appropriate;
tests for foreign materials, as appropriate;
any other additional test according to the European Pharmacopoeia general monograph on herbal substances or to the specific monograph of the herbal substance, as appropriate.
Any treatment used to reduce fungal/microbial contamination or other infestation shall be specified.
Specifications shall include details of the process, tests and limits for residues, as appropriate.
Suppliers of herbal materials shall comply with good agricultural and collection practice. The suppliers shall be audited by the manufacturer of the herbal veterinary medicinal product in accordance with quality risk management principles. Such audits may be outsourced.
5. The following precautions shall be taken regarding storage areas for herbal materials used in the production of veterinary medicinal products:
effective measures shall be implemented to prevent the spread of insects, other animals or micro-organisms brought in with the herbal substance, to prevent fermentation or mould growth and to prevent cross-contamination. Separate enclosed areas shall be used to quarantine incoming herbal substances and for the approved herbal substances;
storage areas shall be well aerated, and the containers shall be located in such a way so as to allow free circulation of air;
where necessary, specific conditions of humidity, temperature or light protection shall be defined and monitored.
6. The identity and quality of herbal materials and of herbal medicinal products shall be determined in accordance with the relevant current European guidance on quality and specifications for herbal medicinal products and traditional herbal medicinal products or, where relevant, with the requirements of specific relevant monographs of the European Pharmacopoeia.
7. The processing instructions shall describe the different operations to be carried out upon the herbal substance such as cleaning, drying, crushing and sifting, including drying time and temperatures, and methods used to control the cut size or the particle size. Written instructions shall be developed and records shall be kept to ensure that each container of herbal substance is carefully examined to detect any adulteration/substitution or presence of foreign matter, such as metal or glass pieces, animal parts or excrement, stones, sand, or rot and signs of decay.
The processing instructions shall also describe security sieving or other methods of removing foreign materials and appropriate procedures for the cleaning/selection of the plant material before the storage of the approved herbal substance or before the start of manufacturing.
For the production of an herbal preparation, instructions shall include details of solvent, time and temperature of extraction, details of any concentration stages and methods used.
8. If dust is generated during processing (including sampling), the use of dust extraction, dedicated premises or other means shall be considered to prevent cross-contamination and facilitate cleaning.
9. The equipment and filtering materials used in the manufacturing process shall be compatible with the extraction solvent, in order to prevent any release or undesirable absorption of the substance that could affect the product.
10. Due to the fact that medicinal plant/herbal substances are heterogeneous in nature, the following measures shall be implemented regarding sampling:
each batch shall be identified by its own documentation;
a reference sample of the plant material is necessary, especially in those cases where the herbal substance is not described in the European Pharmacopoeia or in another Pharmacopoeia of a Member State. Samples of unmilled plant material are required if powders are used.
11. Quality control personnel shall have particular expertise and experience in herbal substances, herbal preparations and/or herbal medicinal products in order to be able to carry out identification tests and recognise adulteration, the presence of fungal growth, infestations, non-uniformity within a delivery of crude material, etc.
1. Because the manufacture of medicated premixes requires the use of large quantities of vegetable matter which is likely to attract insects and rodents, it is particularly important to ensure that premises are designed, equipped and operated in a way that minimises the risk of intrusion thereof in the site. Enhanced pest control systems shall be put in place to monitor and minimise pest ingress and to take action where appropriate.
2. Because of the large volume of dust generated during the production of bulk material for premixes, specific attention shall be paid to the need to avoid cross contamination and facilitate cleaning, for example through the installation of sealed transport systems and dust extraction, whenever possible. The installation of such systems does not, however, eliminate the need for regular cleaning of production areas.
3. Parts of the process likely to have a significant adverse influence on the stability of the active ingredient(s) (e.g. use of steam in pellet manufacture) shall be carried out in an uniform manner from batch to batch.
4. Whenever possible, the manufacture of premixes shall be made in dedicated areas which, if possible, do not form part of the main manufacturing plant. Alternatively, such dedicated areas shall be surrounded by a buffer zone in order to minimise the risk of contamination of other manufacturing areas.
Ectoparasitic veterinary medicinal products for external application to animals may be produced and filled on a campaign basis in pesticide specific areas. However, other categories of veterinary medicinal products shall not be produced in such areas.
As liquids, creams and ointments may be particularly susceptible to microbial and other contamination during manufacture, the following measures shall be considered:
the use of closed systems for processing and transfer is recommended. In cases where the products or open clean containers are exposed to the environment, there shall be effective ventilation with filtered air;
tanks, containers, pipework and pumps shall be designed and installed to facilitate cleaning. In particular, equipment shall include a minimum of dead-legs or sites where residues can accumulate and promote microbial proliferation;
the use of glass apparatus shall be avoided wherever possible. High quality stainless steel is often the material of choice for parts coming into contact with the product;
the chemical and microbiological quality of water used in production shall be specified and monitored. Care shall be taken in the maintenance of water systems in order to avoid the risk of microbial proliferation. After any chemical sanitisation of the water systems, a validated flushing procedure shall be applied to ensure that the sanitising agent has been effectively removed;
materials likely to shed fibres or other contaminants, like cardboard or wooden pallets, shall not enter the areas where products or clean containers are exposed;
the homogeneity of mixtures or suspensions, shall be kept during filling. Special care shall be taken at the beginning of a filling process, after stoppages and at the end of the process to ensure that homogeneity is maintained;
when the finished product is not immediately packaged, the maximum period of storage and the storage conditions shall be specified and adhered to.
This Section provides for additional requirements that are applicable to the manufacture of veterinary medicinal products that contain medicinal gases. For the purposes of this Section, the term ‘gas’ covers any substance that is completely gaseous at 1,013 bar and + 20 °C or has a vapour pressure exceeding 3 bar at + 50 °C.
In the exceptional case of continuous manufacturing, where no intermediate storage of the gas between the manufacture of the active substance and the manufacture of the medicinal product is possible, the whole process (from starting materials of active substance to medicinal finished product) falls under the scope of this Regulation.
Personnel shall be specifically trained on the specific hazards from these products; training programs shall include tanker lorries drivers and subcontracted personnel that can influence the quality of medicinal gases (such as personnel in charge of maintenance of cylinders [For the purposes of this Section, ‘cylinder’ means a container, usually cylindrical, suited for compressed, liquefied or dissolved gas, fitted with a device to regulate the spontaneous outflow of gas at atmospheric pressure and room temperature.] or valves).
3.1. Cylinders and mobile cryogenic vessels [For the purposes of this Section, ‘mobile cryogenic vessel’ means a mobile thermally insulated container designed to maintain the contents in a liquid state. This term does not include the tankers.] shall be checked, prepared, filled and stored in separate areas from non-medicinal gases, and there shall be no exchange of cylinders/mobile cryogenic vessels between these areas. However, it is acceptable to check, prepare, fill and store other gases in the same areas, provided that such operations are performed according to good manufacturing practice.
3.2. Premises shall be designed to provide separate marked areas for different gases and clear identification and segregation of cylinders/mobile cryogenic vessels at various stages of processing (e.g. ‘waiting checking’ ‘awaiting filling’, ‘quarantine’, ‘certified’, ‘rejected’, ‘prepared deliveries’). The method used to achieve these various levels of segregation will depend on the nature, extent and complexity of the overall operation. Marked-out floor areas, partitions, barriers, signs, labels or other appropriate means may be used.
3.3. Cylinders/home cryogenic vessels [For the purposes of this Section, ‘home cryogenic vessel’ means a mobile cryogenic vessel designed to hold liquid oxygen and dispense gaseous oxygen at patients’ home.] (whether empty after sorting or maintenance or filled) shall be stored under cover and protected from adverse weather conditions. Filled cylinders/mobile cryogenic vessels shall be stored in a manner that ensures that they will be delivered in a clean state, compatible with the environment in which they will be used.
3.4. Specific storage conditions required by the marketing authorisation (e.g. for gas mixtures where phase separation occurs on freezing) shall be respected.
4.1. Equipment shall be designed to ensure that the correct gas is filled into the correct container. [For the purposes of this Section, ‘container’ means a cryogenic vessel (tank, tanker or other type of mobile cryogenic vessel) a cylinder, a cylinder bundle or any other package that is in direct contact with the gas.] There shall normally be no cross connections between pipelines carrying different gases. If cross connections are needed (e.g. filling equipment of mixtures), as part of the qualification process, it shall be ensured that there is no risk of cross contamination between the different gases. In addition, manifolds [For the purposes of this Section, ‘manifold’ means equipment or apparatus designed to enable one or more gas containers to be emptied or filled at the same time.] shall be equipped with specific connections. The use of connections meeting different standards at the same filling site shall be carefully controlled, as well as the use of adaptors that may be needed to bypass the specific fill connection systems.
4.2. Tanks [For the purposes of this Section, ‘tank’ means a static thermally insulated container designed for the storage of a liquefied or a cryogenic gas. A tank can also be called ‘fixed cryogenic vessel’.] and tankers [For the purposes of this Section, ‘tanker’ means a thermally insulated container fixed on a vehicle for the transport of a liquefied or a cryogenic gas.] shall be dedicated to a single and defined quality of gas. However, medicinal gases may be stored or transported in the same tanks/containers for intermediate storage/tankers as the same non-medicinal gas, provided that the quality of the latter is at least equal to the quality of the medicinal gas, that standards of good manufacturing practice are maintained and that the approach is justified in accordance with quality risk management principles.
4.3. A common system supplying gas to medicinal and non-medicinal gas manifolds is only acceptable if there is a validated method to prevent backflow from the non-medicinal gas line to the medicinal gas line.
4.4. Filling manifolds shall be dedicated to a single medicinal gas or to a given mixture of medicinal gases. In exceptional cases, filling gases used for non-medicinal purposes on manifolds used for medicinal gases may be acceptable if duly justified and performed under control. In these cases, the quality of the non-medicinal gas shall be at least equal to the required quality of the medicinal gas and standards of good manufacturing practice shall be maintained. Further, in such cases, the filling shall be carried out on campaign basis.
4.5. Repair and maintenance operations (including cleaning and purging [For the purposes of this Section, ‘purge’ means the removal of residual gas from a container/system by first pressurising and then venting the gas used for purging to 1.013 bar.]) of equipment, shall not adversely affect the quality of the medicinal gases. In particular, procedures shall describe the measures to be taken after repair and maintenance operations involving breaches of the system’s integrity. Specifically, it shall be demonstrated that the equipment is free from any contamination that may adversely affect the quality of the finished product before releasing it for use. Records shall be maintained.
4.6. A procedure shall describe the measures to be taken when a tanker is back into medicinal gas service (after transporting non-medicinal gas under the conditions referred in Section V.4.2, or after a maintenance operation), which shall include appropriate analytical testing.
5.1. Data included in the records for each batch of medicinal gases shall ensure that each filled container is traceable to significant aspects of the relevant filling operations. As appropriate, the following shall be entered:
name of the product;
batch number;
date and time of the filling operation;
identification of the person(s) carrying out each significant step (e.g. line clearance, receipt, preparation before filling, filling, etc.);
batch(es) reference(s) for the gas(es) used for the filling operation, including status;
equipment used (e.g. filling manifold);
quantity of cylinders/mobile cryogenic vessels before filling, including individual identification references and water capacity(ies);
pre-filling operations performed;
key parameters that are needed to ensure correct filling at standard conditions;
results of the appropriate checks to ensure that the cylinders/mobile cryogenic vessels have been filled;
a sample of the batch label;
specification of the finished product and results of the quality control tests (including reference to the calibration status of the test equipment);
quantity of rejected cylinders/mobile cryogenic vessels, with individual identification references and reasons for rejections;
details of any problems or unusual events, and signed authorisation for any deviation from filling instructions;
certification statement by the qualified person, date and signature.
5.2. Records shall be maintained for each batch of gas intended to be delivered into tanks in healthcare facilities. These records shall, as appropriate, include the following:
name of the product;
batch number;
identification reference for the tank;
date and time of the filling operation;
identification of the person(s) carrying out the filling of the tank (tanker);
reference to the supplying tanker (tank), reference to the source gas as applicable;
relevant details concerning the filling operation;
specification of the finished product and results of the quality control tests (including reference to the calibration status of the test equipment);
details of any problems or unusual events, and signed authorisation for any deviation from filling instructions;
certification statement by the qualified person, date and signature.
6.1. Transfers and deliveries of cryogenic and liquefied gas [For the purposes of this Section, ‘liquefied gas’ means a gas which, when packaged for transport, is partially liquid (or solid) at a temperature above – 50 oC.] shall be done in accordance with the following requirements:
The transfer of cryogenic or liquefied gases from primary storage, including the controls before the transfer, shall be in accordance with validated procedures designed to avoid the possibility of contamination. Transfer lines shall be equipped with non-return valves [For the purposes of this Section, ‘non-return valve’ means a valve that permits flow in one direction only.] or other suitable alternatives. Flexible connections, coupling hoses and connectors shall be flushed with the relevant gas before use.
The transfer hoses used to fill tanks and tankers shall be equipped with product-specific connections. The use of adaptors allowing the connection of tanks and tankers not dedicated to the same gases shall be adequately controlled.
Deliveries of gas may be added to tanks containing the same defined quality of gas provided that a sample is tested to ensure that the quality of the delivered gas is acceptable. That sample may be taken from the gas to be delivered or from the receiving tank after delivery.
The filling of tanks retained by customers at customer’s premises is to be done according to Section V.7.3.
6.2. Filling and labelling of cylinders and mobile cryogenic vessels shall be done in accordance with the following requirements:
Before filling cylinders and mobile cryogenic vessels, a batch (batches) of gas(es) shall be determined, controlled according to specifications and approved for filling.
In the case of continuous processes, adequate in-process controls shall be implemented to ensure that the gas complies with the specifications.