1. The additional requirements set out in this Annex shall apply to the manufacture, control and testing of biological and immunological veterinary medicinal products, with the exception of inactivated immunological veterinary medicinal products which are manufactured from pathogens and antigens obtained from an animal or animals in an epidemiological unit and used for the treatment of that animal or those animals in the same epidemiological unit or for the treatment of an animal or animals in a unit having a confirmed epidemiological link.
Throughout the Annex, reference to ‘biological veterinary medicinal products’ or ‘biologicals’ is to be understood as encompassing also immunologicals.
2. Antibiotics are generally not considered biologicals. Nevertheless, manufacturers are advised to follow the requirements set out in this Annex with regard to manufacturing procedures described in this document that are used in the manufacture of such veterinary medicinal products.
3. Table 1 illustrates the manufacturing activities which are generally within the scope of this Annex.
[GMP principles shall be adhered to.] [See Section IV for the extent to which GMP principles apply.] [See Section VI for the extent to which GMP applies.] [See Section VI for the extent to which GMP applies. Maintenance of working cell bank is expected to take place in a GMP environment.] [The standards of good agricultural and collection practice for starting materials of herbal origin (GACP) is applicable.]
Type and source of material | Example product |
Manufacturing steps covered by this Annex shown in grey
GMP requirements shall increase from the earlier steps (e.g. collection) to the final manufacturing steps (formulation, filling). For earlier stages of manufacturing, GMP principles shall at least be adhered to.
Human source | Urine derived enzymes, hormones | Collection of material | Mixing, and/or initial processing | Isolation and purification | Formulation, filling
Animal or plant sources (not genetically modified/edited) | Heparins, insulin, enzymes, proteins, allergen extract, immunosera | Collection of plant or animal material | Cutting, mixing, and/or initial processing | Isolation and purification | Formulation, filling
Virus or bacteria /fermentation/cell culture, etc. | Viral or bacterial vaccines; enzymes, proteins | Establishment & maintenance of MCB, WCB, MSL, WSL | Cell culture and/or fermentation | Inactivation when applicable, isolation and purification | Formulation, filling
Biotechnology- fermentation/cell culture | Recombinant products, MAb, allergens, vaccines | Establishment & maintenance of MCB and WCB, MSL, WSL | Cell culture and/or fermentation | Isolation, purification, modification | Formulation, filling
Animal sources, (genetically modified/edited) | Recombinant proteins | Master and working (genetically modified/edited) bank | Collection, cutting, mixing, and/or initial processing | Isolation, purification, modification | Formulation, filling
Plant sources: (genetically modified/edited) | Recombinant proteins, vaccines, allergen | Master and working (genetically modified/edited) bank | Growing, harvesting | Initial extraction, isolation, purification, modification | Formulation, filling
4. In cases where there is a continuous process from the sourcing/isolation of the active substance from a biological source to the manufacturing of the finished product (e.g. veterinary medicinal products that consists of cells, viral-based vaccines, phages), the requirements of this Regulation shall apply to the entire manufacturing process.
1. Personnel (including those concerned with cleaning and maintenance) employed in areas where biological products are manufactured and tested shall receive initial and periodic retraining specific to the products manufactured and their respective tasks, including measures to protect the product, personnel and the environment, as well as – where appropriate – training on microbiology.
2. Personnel shall be protected against a possible infection with the biological agents used in the manufacture. In the case of biological agents known to cause disease in humans, adequate measures shall be taken to prevent infection of personnel working with the agent or with experimental animals. Where appropriate, relevant vaccination and health monitoring shall be offered having regard to the specific characteristics of the manufactured product (e.g. BCG vaccine [Bacillus Calmette–Guérin (BCG) vaccine.], rabies, brucella, leptospira, tuberculin products) and the tasks of the staff.
3. When a heath condition that may have a negative impact on the quality of the product is declared by the relevant personnel or otherwise becomes apparent, access to the production or control area shall be barred.
4. Where required to minimise the opportunity for cross-contamination, restrictions on the movement of all personnel (including quality control, maintenance and cleaning staff) shall be applied on the basis of quality risk management principles [Personnel entering a contained area where organisms have not been handled in open circuit operations in the previous twelve hours are not regarded as being at risk of contamination, unless the organism involved is a biological agent where the corresponding disease does not exist in the relevant country or geographical area, or where the corresponding disease is subject to prophylactic measures or an eradication programme undertaken in the relevant country or geographical area.]. In general, personnel shall not pass from areas where exposure to live micro-organisms, genetically modified/genome edited organisms, toxins or animals occurs to areas where other products, or different organisms are handled. If such passage is unavoidable, appropriate contamination control measures commensurate to the risks shall be implemented.
5. Adequate measures shall be implemented to prevent biological agents being taken outside the manufacturing plant by personnel acting as a carrier. Dependent on the type of biological agent, such measures may include a complete change of clothes and compulsory showering before leaving the production area.
1.1. Premises shall be designed in such a way as to control the risks to the product and the risks to the environment. This may be achieved by the use of contained, clean, or controlled areas. In particular:
Live biological agents that are highly pathogenic shall be handled in contained areas (including quality control operations, research and diagnostic services, etc). The level of containment shall be adapted to the pathogenicity of the agent.
Without prejudice to the containment measures that may be required for certain biological organisms as provided for under (a), production of biological agents may generally take place in controlled areas provided it is carried out in totally enclosed and sterilised equipment and all relevant connections are made in accordance with the requirements set out in Annex I.
Inactivated biological agents shall be handled in clean areas. Clean areas shall also be used when handling non-infected cells isolated from multicellular organisms and, where appropriate, filtration-sterilised media.
Open circuit operations involving products or components not subsequently sterilised shall be carried in accordance with the requirements set out in Annex I, where relevant.
With the exception of blending and subsequent filling operations (or when closed systems are used), only one biological agent shall be handled at a given time within an area.
Production operations such as cell maintenance, media preparation, virus culture, etc. which are likely to cause contamination shall be performed in separate areas, unless appropriate organisational and technical measures may be put in place to prevent contamination.
Production areas where biological agents particularly resistant to disinfection (e.g. spore-forming bacteria) are handled shall be separated and dedicated to that particular purpose until the biological agents have been inactivated, unless appropriate organisational and technical measures may be put in place to prevent contamination.
1.2. As part of the contamination control strategy, the degree of environmental control of particulate and microbial contamination of the production premises shall be adapted to the active substance, intermediate or finished product and the production step, bearing in mind the potential level of contamination of the starting materials and the risks to the product. Where relevant in accordance with quality risk management principles, the environmental monitoring programme shall be supplemented by the inclusion of methods to detect the presence of specific microorganisms (i.e. host organism, yeast, moulds, anaerobes, etc.).
1.3. Manufacturing and storage facilities, processes and environmental classifications shall be designed to prevent the extraneous contamination of products. Where processes are not closed and there is therefore exposure of the product to the immediate room environment (e.g. during additions of supplements, media, buffers, gases) adequate control measures shall be put in place, including engineering and environmental controls. Relevant aspects addressed in Annex I shall be applied, including aspects related to the required environmental grades and associated controls.
1.4. Air handling units shall be designed, constructed and maintained to minimise the risk of cross-contamination between different manufacturing areas, to provide relevant containment where applicable, and may need to be specific for an area. Consideration, based on quality risk management principles, shall be given to the use of single pass air systems.
1.5. Positive pressure areas shall be used to process sterile products but negative pressure in specific areas at the point of exposure of pathogens is acceptable for containment reasons. Where negative pressure areas or safety cabinets are used for aseptic processing of materials with particular risks (e.g. pathogens) they shall be surrounded by a positive pressure clean zone of appropriate grade. These pressure cascades shall be clearly defined and continuously monitored with appropriate alarm settings.
1.6. Air vent filters shall be hydrophobic and validated for their scheduled life span with integrity testing at appropriate intervals based on appropriate quality risk management principles.
1.7. Where necessary to address the contamination risks, equipment passes and changing rooms shall have an interlock mechanism or other appropriate system to prevent the opening of more than one door at a time. Changing rooms shall be supplied with air filtered to the same standard as that for the work area and equipped with air extraction facilities to produce an adequate air circulation independent of that of the work area. Equipment passes shall normally be ventilated in the same way, but unventilated passes, or those equipped with supply air only, may be acceptable.
1.8. Drainage systems shall be designed so that effluents can be effectively neutralised or decontaminated to minimise the risk of cross-contamination. Local regulation shall be followed to minimise the risk of contamination of the external environment according to the risk associated with the biohazardous nature of waste materials.
1.9. Containment premises shall be designed so as to ensure that they can be easily disinfected and shall have the following characteristics:
Absence of direct venting to the outside.
Ventilation with air at negative pressure: Air shall be extracted through HEPA filters and not be re circulated except to the same area, and provided further HEPA filtration is used (normally this condition would be met by routing the recirculated air through the normal supply HEPAs for that area). Recycling of air between areas is acceptable only if it passes through two exhaust HEPAs, the first of which is continuously monitored for integrity, and there are adequate measures for safe venting of exhaust air should this filter fail.
Where negative pressure areas are used for containment purposes of aseptic processing of materials with particular risks, they shall be combined with a positive pressure clean zone of appropriate grade (pressure bubble or sink airlock). These pressure cascades shall be clearly defined and continuously monitored with appropriate alarm settings.
By way of derogation from (b), air from manufacturing areas used for the handling of exotic organisms [For the purpose of this Annex, ‘exotic organism’ means a biological agent where the corresponding disease does not exist in a relevant country or geographical area, or where the disease is the subject of prophylactic measures or an eradication programme undertaken in the relevant country or geographical area.] shall be vented through two sets of HEPA filters in series, and air from production areas shall not be re-circulated.
A system shall be put in place for the collection and disinfection of liquid effluents including the contaminated condensate from sterilisers, biogenerators, etc. In addition, solid wastes, including animal carcasses, shall be disinfected, sterilised or incinerated as appropriate. Contaminated filters shall be removed using a safe method.
Changing rooms shall be designed and used as air locks and equipped with washing and showering facilities if appropriate. Air pressure differentials shall be such that there is no flow of air between the work area and the external environment or a risk of contamination of the outer clothing worn outside the area.
An airlock system is in place for the passage of equipment, which is constructed so that there is no flow of contaminated air between the work area and the external environment or a risk of contamination of the equipment within the lock. The airlock shall be of a suitable size to enable the effective surface decontamination of materials being passed through it. Consideration shall be given to having a timing device on the door interlock to allow sufficient time for the decontamination process to be effective.
Where appropriate, a barrier double-door autoclave shall be used for the secure removal of waste materials and introduction of sterile items.
1.10. The measures and procedures implemented for containment to address operator and environmental safety shall not conflict with those required to ensure product quality.
1.11. Manufacture of biologicals in a multi-product facility is acceptable where appropriate measures are implemented to prevent cross-contamination, such as:
measures to prevent cross-contamination to non-related areas or equipment (e.g. use of single use components and engineering measures such as closed systems);
validated cleaning and decontamination procedures before the subsequent manufacture of other products, covering also heating, ventilation and air conditioning (HVAC) system;
environmental monitoring in adjacent areas – during manufacture and after completion of cleaning and decontamination – specific for the micro-organism being manufactured. Risks arising from the use of certain monitoring equipment (e.g. airborne particle monitoring) in areas handling live and/or spore-forming organisms shall be duly considered;
controls on the movement/removal of products, equipment, ancillary equipment (e.g. for calibration and validation) and disposable items to prevent contamination of other areas, other products or different product stages (e.g. prevent contamination of inactivated or toxoided products with non-inactivated products);
campaign-based manufacturing.
Where production involves the manufacture of multiple small batches from different starting materials, factors such as the health status of donors and the risk of total loss of product shall be taken into account when considering the acceptance of concurrent working.
1.12. For finishing operations (formulation, filling and packaging), the assessment whether dedicated facilities are required shall also take into consideration the specific characteristics of the concerned biological product and the characteristics of other products, including any non-biological products, handled in the same facility.
Other control measures for finishing operations may include the need for specific addition sequences, mixing speeds, time and temperature controls, limits on exposure to light, as well as containment and cleaning procedures in the event of spillages.
2.1. Equipment used during handling of live organisms and cells, including equipment used for sampling, shall be suitable to prevent contamination during processing, facilitate decontamination and sterilisation (where applicable), and to avoid any mix-up between different organisms or products.
Particular attention shall be paid to control measures to avoid cross-contamination from parts of equipment that are not fixed, such as pipes, valves and filters (e.g. appropriate identification as to their function).
2.2. Equipment used for the storage of biological agents or products shall be suitable and used in such a manner as to prevent any possible mix-up. All stored items shall be clearly and unambiguously labelled and in leak-proof containers.
2.3. Where relevant, equipment shall be fitted with recording and/or alarm systems (e.g. equipment requiring temperature control). To avoid breakdowns, a system of preventive maintenance, together with trend analysis of recorded data, shall be implemented.
2.4. Close equipment used for primary containment shall be designed and periodically tested to ensure the prevention of escape of biological agents into the immediate working environment. Inlets and outlets for gases shall be protected so as to achieve adequate containment, e.g. by the use of sterilising hydrophobic filters. The introduction or removal of material shall take place using a sterilisable closed system, or possibly in an appropriate laminar air flow.
2.5. Where necessary, equipment shall be properly sterilised by a validated method. Equipment used for purification, separation or concentration shall be sterilised or disinfected at least between each use for different products. The effect of the sterilisation methods on the effectiveness and validity of the equipment shall be studied in order to determine the life span of the equipment.
2.6. The use of ‘clean in place’ [For the purposes of this Annex, ‘clean in place’ means a method, usually automated, used to clean the internal surfaces of equipment, piping, vessels, and associated fittings without disassembling them.] and ‘steam in place’ [For the purposes of this Annex, ‘steam in place’ means a method, usually automated, of sterilising the internal surfaces of equipment, piping, vessels, and associated fittings by using steam, without disassembling the equipment.] (‘sterilisation in place’) systems shall be used where appropriate. Valves on fermentation vessels shall be completely steam sterilisable.
2.7. The loading of freeze dryers requires an appropriate clean/contained area. Unloading freeze dryers contaminates the immediate environment. Therefore, for single-ended freeze dryers, the clean room shall be decontaminated before a further manufacturing batch is introduced into the area, unless that batch involves the same organism(s). Double door freeze dryers shall be sterilised after each cycle unless opened in a clean area. Sterilisation of freeze dryers shall be done in accordance with Annex I. In case of campaign working, they shall at least be sterilised after each campaign.
The use of animals or animal materials in the manufacture of veterinary medicinal products is subject to specific additional requirements:
Biological substances and products shall comply with the latest version of the Note for guidance on minimising the risk of transmitting animal spongiform encephalopathy agents via human and veterinary medicinal products.
Specifications for materials of animal origin shall consider aspects such as age, weight and health status of the animals, as appropriate, and in accordance with the terms of the marketing authorisation.
Where applicable, pharmacopeia requirements shall be complied with, including the need for specific tests at defined stages.
A health programme shall be established to monitor adventitious agents that are of concern (zoonotic diseases, diseases of source animals). Specialist advice shall be obtained for the establishment of such programme. In particular, reports from trustworthy sources on national disease prevalence shall be considered when performing the assessment of risk and mitigation factors. Such sources include the World Organisation for Animal Health (WOAH) [https://www.woah.org/en/home.], as well as information on health monitoring and control programme(s) at national and local level.
Instances of ill-health occurring in the source/donor animals shall be investigated with respect to their suitability and the suitability of in-contact animals for continued use (in manufacture, as sources of starting and raw materials, in quality control and safety testing). Decisions shall be documented.
A look-back procedure shall be in place to inform the decision-making process on the continued suitability of the biological active substance or medicinal product in which the animal sourced starting or raw materials have been used or incorporated. This decision-making process may include the re-testing of retained samples from previous collections from the same donor animal (where applicable) to establish the last negative donation.
The withdrawal period of therapeutic agents used to treat source/donor animals shall be documented and used to determine the removal of those animals from the programme for defined periods.
Particular care shall be paid to the prevention and monitoring of infections in the source/donor animals, including addressing aspects regarding the sourcing, the facilities, the husbandry, the biosecurity procedures, the testing regimes or the control of bedding and feed materials. This is of special relevance to specified pathogen free [For the purposes of this Annex, ‘specified pathogen free’ means animals free from specified pathogens. Such flocks or herds share a common environment and have their own caretakers who have no contact with non-specified pathogen free groups.] animals where PhEur monograph requirements shall be met. Housing and health monitoring shall be defined for other categories of animals (e.g. healthy flocks or herds).
For products manufactured from animals that have been genetically modified or whose genome has been edited, traceability shall be maintained in the creation of such animals from the source animals.