3 Appendix 10 Determination of the instantaneous proxy power from CO2 mass flow, Regulation (EU) 2022/2387

In forcesince 30 Aug 2022

‘Proxy power’ means a value obtained by simple linear interpolation for the sole purpose of the determination of valid events during in-service monitoring as described in Appendix 4. This methodology is for engines designed without a communication interface capable to provide torque and speed data in accordance with Table 1 of Appendix 7. The calculation is based upon the assumption that, for all engine types within an engine family:

(a)

the ratio of work and CO2 mass on the reference laboratory test cycle are similar;

(b)

there is a linear relationship between power and CO2 mass flow rate; and,

(c)

an operating engine that produces no net power emits no CO2.

2.1. For the sole purpose of the calculations in Appendix 4, an instantaneous power for the engine under ISM test shall be computed from the measured CO2 mass flow at a time increment equal to the data sampling period. For this calculation a simplified engine-family-specific CO2 (‘Veline’) constant shall be used.

2.2. The Veline constant shall be calculated from the applicable reference values set out in point 2.1.2 of Appendix 5.

The Veline constant, Kveline, is computed from the reference mass of CO2 emitted by the parent engine at type-approval divided by the work performed by the parent engine at type-approval using equation 10-1.

Kveline

mCO2,ref

Wref

(10-1)

Where:

Kvelineis the ‘Veline’ constant, g/kWh;

mCO2,refis the reference mass of CO2 emitted by the parent engine in the reference laboratory test cycle, g;

Wrefis the reference work performed by the parent engine in the reference laboratory test cycle, kWh.

2.3. The instantaneous proxy power of the engine under ISM test is calculated from the instantaneous CO2 mass flow using equation 10-2

(10-2)

Where:

Pi,proxyis the instantaneous proxy power, kW;

is the instantaneous mass flow of CO2 emitted by the engine under test, g/s.