ANNEX VI Technical documentation, Regulation (EU) 2019/2015

In forcesince 30 Sep 2023cited 2×
1.

The technical documentation referred to in point 1(d) of Article 3 shall include:

(a)

the name and address of the supplier;

(b)

supplier’s model identifier;

(c)

the model identifier of all equivalent models already placed on the market;

(d)

identification and signature of the person empowered to bind the supplier;

(e)

the declared values for the following technical parameters; these values are considered as the declared values for the purpose of the verification procedure in Annex IX:

(1)

useful luminous flux (Φuse) in lm;

(2)

colour rendering index (CRI);

(3)

on-mode power (Pon) in W;

(4)

beam angle in degrees for directional light sources (DLS);

(4a)

peak luminous intensity in cd for directional light sources (DLS);

(5)

correlated colour temperature (CCT) in K;

(6)

standby power (Psb) in W, including when it is zero;

(7)

networked standby power (Pnet) in W for connected light sources (CLS);

(7a)

R9 colour rendering index value for LED and OLED light sources;

(7b)

survival factor for LED and OLED light sources;

(7c)

lumen maintenance factor for LED and OLED light sources;

(7d)

indicative lifetime L70B50 for LED and OLED light sources;

(8)

displacement factor (cos φ1) for LED and OLED mains light sources;

(9)

colour consistency in MacAdam ellipse steps for LED and OLED light sources;

(10)

luminance-HLLS in cd/mm2 (only for HLLS);

(11)

flicker metric (PstLM) for LED and OLED mains light sources;

(12)

stroboscopic effect metric (SVM) for LED and OLED mains light sources;

(13)

excitation purity, only for CTLS, for the following colours and dominant wavelength within the given range:

ColourDominant wave-length range

Blue440 nm – 490 nm

Green520 nm – 570 nm

Red610 nm – 670 nm;

(f)

the calculations performed with the parameters, including the determination of the energy efficiency class;

(g)

references to the harmonised standards applied or other standards used;

(h)

testing conditions if not described sufficiently in point (g);

(i)

the reference control settings, and instructions on how they can be implemented, where applicable;

(j)

instructions on how to remove lighting control parts and/or non-lighting parts, if any, or how to switch them off or minimise their power consumption during light source testing;

(k)

specific precautions that shall be taken when the model is assembled, installed, maintained or tested.

2.

The elements listed under point 1 shall also constitute the mandatory specific parts of the technical documentation that the supplier shall enter into the database, pursuant to point 5 of Article 12 of Regulation (EU) 2017/1369.