The technical documentation referred to in point 1(d) of Article 3 shall include:
the name and address of the supplier;
supplier’s model identifier;
the model identifier of all equivalent models already placed on the market;
identification and signature of the person empowered to bind the supplier;
the declared values for the following technical parameters; these values are considered as the declared values for the purpose of the verification procedure in Annex IX:
useful luminous flux (Φuse) in lm;
colour rendering index (CRI);
on-mode power (Pon) in W;
beam angle in degrees for directional light sources (DLS);
peak luminous intensity in cd for directional light sources (DLS);
correlated colour temperature (CCT) in K;
standby power (Psb) in W, including when it is zero;
networked standby power (Pnet) in W for connected light sources (CLS);
R9 colour rendering index value for LED and OLED light sources;
survival factor for LED and OLED light sources;
lumen maintenance factor for LED and OLED light sources;
indicative lifetime L70B50 for LED and OLED light sources;
displacement factor (cos φ1) for LED and OLED mains light sources;
colour consistency in MacAdam ellipse steps for LED and OLED light sources;
luminance-HLLS in cd/mm2 (only for HLLS);
flicker metric (PstLM) for LED and OLED mains light sources;
stroboscopic effect metric (SVM) for LED and OLED mains light sources;
excitation purity, only for CTLS, for the following colours and dominant wavelength within the given range:
ColourDominant wave-length range
Blue440 nm – 490 nm
Green520 nm – 570 nm
Red610 nm – 670 nm;
the calculations performed with the parameters, including the determination of the energy efficiency class;
references to the harmonised standards applied or other standards used;
testing conditions if not described sufficiently in point (g);
the reference control settings, and instructions on how they can be implemented, where applicable;
instructions on how to remove lighting control parts and/or non-lighting parts, if any, or how to switch them off or minimise their power consumption during light source testing;
specific precautions that shall be taken when the model is assembled, installed, maintained or tested.
The elements listed under point 1 shall also constitute the mandatory specific parts of the technical documentation that the supplier shall enter into the database, pursuant to point 5 of Article 12 of Regulation (EU) 2017/1369.