The energy efficiency class of light sources shall be determined as set out in Table 1, on the basis of the total mains efficacy ηTM, which is calculated by dividing the declared useful luminous flux Φuse (expressed in lm) by the declared on-mode power consumption Pon (expressed in W) and multiplying by the applicable factor FTM of Table 2, as follows:
ηTM = (Φuse/Pon) × FTM (lm/W).
Energy efficiency class | Total mains efficacy ηΤM (lm/W)
A | 210 ≤ ηΤM
B | 185 ≤ ηΤM < 210
C | 160 ≤ ηΤM < 185
D | 135 ≤ ηΤM < 160
E | 110 ≤ ηΤM < 135
F | 85 ≤ ηΤM < 110
G | ηΤM < 85
Light source type | Factor FTM
Non-directional (NDLS) operating on mains (MLS) | 1,000
Non-directional (NDLS) not operating on mains (NMLS) | 0,926
Directional (DLS) operating on mains (MLS) | 1,176
Directional (DLS) not operating on mains (NMLS) | 1,089