ANNEX IX, Regulation (EU) 2015/1187

In forcesince 27 Apr 2015
1.

The Energy Efficiency Index (EEI) of solid fuel boilers shall be calculated for the preferred fuel and rounded to the nearest integer as:

EEI = ηson × 100 × BLF – F(1) – F(2) × 100 + F(3) × 100

where:

(a)

ηson is the seasonal space heating energy efficiency in active mode, calculated as set out in point 4(b) of Annex VIII;

(b)

BLF is the biomass label factor, which is 1,45 for biomass boilers and 1 for fossil fuel boilers;

(c)

F(1) accounts for a negative contribution to the energy efficiency index due to adjusted contributions of temperature controls; F(1) = 3;

(d)

F(2) accounts for a negative contribution to the energy efficiency index by auxiliary electricity consumption, and is calculated as set out in point 4(c) of Annex VIII;

(e)

F(3) accounts for a positive contribution to the energy efficiency index by the electrical efficiency of solid fuel cogeneration boilers, and is calculated as follows:

F(3) = 2,5 × ηel,n

2.

The Energy Efficiency Index (EEI) of packages of a solid fuel boiler, supplementary heaters, temperature controls and solar devices shall determined in accordance with point 2 of Annex IV.