1.1.
The information in the product fiche of the solid fuel boiler shall be provided in the following order and shall be included in the product brochure or other literature provided with the product:
supplier's name or trademark;
supplier's model identifier;
the energy efficiency class of the model, determined in accordance with Annex II;
the rated heat output in kW, rounded to the nearest integer;
the energy efficiency index, rounded to the nearest integer and calculated in accordance with Annex IX;
the seasonal space heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with Annex VIII;
any specific precautions that shall be taken when the solid fuel boiler is assembled, installed or maintained;
in the case of solid fuel cogeneration boilers the electrical efficiency in %, rounded to the nearest integer;
1.2.
One product fiche may cover a number of solid fuel boiler models supplied by the same supplier.
1.3.
The information contained in the product fiche may be given in the form of a copy of the label, either in colour or in black and white. Where this is the case, the information listed in point 1.1 not already displayed on the label shall also be provided.
The fiche for packages of a solid fuel boiler, supplementary heaters, temperature controls and solar devices shall contain the information set out in Figure 1 or Figure 2, as appropriate, for evaluating the energy efficiency index of the package offered, including the following information:
(a)Ithe value of the energy efficiency index of the primary solid fuel boiler;
(b)IIthe factor for weighting the heat output of primary solid fuel boiler and supplementary heaters of a package as set out in Tables 2 and 3 of this Annex, as appropriate;
(c)IIIthe value of the mathematical expression: 294/(11 · Pr), whereby Pr refers to the primary solid fuel boiler;
(d)IVthe value of the mathematical expression 115/(11 · Pr), whereby Pr refers to the primary solid fuel boiler.
[The intermediate values are calculated by linear interpolation between the two adjacent values.]
[Pr refers to the primary solid fuel boiler.]
Psup/(Pr + Psup) | II, package without hot water storage tank | II, package with hot water storage tank
0 | 0 | 0
0,1 | 0,30 | 0,37
0,2 | 0,55 | 0,70
0,3 | 0,75 | 0,85
0,4 | 0,85 | 0,94
0,5 | 0,95 | 0,98
0,6 | 0,98 | 1,00
≥ 0,7 | 1,00 | 1,00
[Pr refers to the primary solid fuel boiler.]
Pr/(Pr + Psup) | II, package without hot water storage tank | II, package with hot water storage tank
0 | 1,00 | 1,00
0,1 | 0,70 | 0,63
0,2 | 0,45 | 0,30
0,3 | 0,25 | 0,15
0,4 | 0,15 | 0,06
0,5 | 0,05 | 0,02
0,6 | 0,02 | 0
≥ 0,7 | 0 | 0