For testing compliance of migration from plastic food contact materials and articles, an analytical method in accordance with the requirements of Article 34 of Regulation (EU) 2017/625 of the European Parliament and of the Council [Regulation (EU) 2017/625 of the European Parliament and of the Council of 15 March 2017 on official controls and other official activities performed to ensure the application of food and feed law, rules on animal health and welfare, plant health and plant protection products, amending Regulations (EC) No 999/2001, (EC) No 396/2005, (EC) No 1069/2009, (EC) No 1107/2009, (EU) No 1151/2012, (EU) No 652/2014, (EU) 2016/429 and (EU) 2016/2031 of the European Parliament and of the Council, Council Regulations (EC) No 1/2005 and (EC) No 1099/2009 and Council Directives 98/58/EC, 1999/74/EC, 2007/43/EC, 2008/119/EC and 2008/120/EC, and repealing Regulations (EC) No 854/2004 and (EC) No 882/2004 of the European Parliament and of the Council, Council Directives 89/608/EEC, 89/662/EEC, 90/425/EEC, 91/496/EEC, 96/23/EC, 96/93/EC and 97/78/EC and Council Decision 92/438/EEC (Official Controls Regulation) (OJ L 95, 7.4.2017, p. 1, ELI: http://data.europa.eu/eli/reg/2017/625/oj).] shall be selected, applying the following specific performance criteria:
The analytical method working range of analytical methods shall be at least RL × SML to RU × SML, as described in the relevant guidance documents, where
RL is the relative lower method working range threshold,
RU is the relative upper method working range threshold,
RU shall be 2. RL shall be 0,2 unless 0,2 × SML is below the analytical limit of quantification (LOQ) of the substance then the RL × SML is set at the LOQ of the substance.
Prior to the verification of compliance with a SML, the specific migration test result, m, needs to be corrected, if relevant: (1) by the real surface-to-volume ratio ((S/V)real) and the surface-to-volume ratio (S/V)test in accordance with Article 17; and/or (2) by the correction factor (CT2) used in the sub-columns for the food simulants D2 and E in Table 2 of Annex III to Regulation (EU) No 10/2011; and/or (3) by the FRF in accordance with point 4.1 of this Annex. When the results are corrected in application of CT2 in combination with the FRF, in accordance with point 4.1 in Annex V, the combined correction factor shall not exceed 5, unless the correction factor laid down in Table 2 of Annex III exceeds 5.
The reproducibility coefficient of variation CVR, which can be expressed in percentage if multiplied by 100, is used to calculate the relative standard measurement uncertainty with the purpose to evaluate compliance. The formulas for calculating the CVR are as follows:
CVR = 0,22 for mc <0,12 × 10-6 kg /kg; and,
CVR = 2(1-½log(mc))/100 for 0,12 × 10-6 kg/kg ≤ mc ≤ 0,138 kg/kg.
Where mc is the specific migration test result of a substance or, if relevant, the corrected specific migration result that is to be evaluated against the SML set out in this Regulation, the standard measurement uncertainty of mc of a substance, u(mc), shall be determined as follows: u(mc) = CVR × mc.
The compliance with the SML shall then be evaluated by applying the following specific performance criterion, where mc is to be evaluated against the SML:
If (mc - SML)/[(u(mc)] > 1,64, then mc exceeds the SML.
If mc is higher than the SML the mc of a substance shall be considered non-compliant. In addition, the rules in Chapter 1-4 of this Annex shall apply.
The material or article shall be stored as indicated on the packaging label or under conditions adequate for the packaged food if no instructions are given. The food shall be removed from contact with the material or article before its expiration date or any date by which the manufacturer has indicated the product should be used for reasons of quality or safety.
The food shall be treated in accordance with the cooking instructions on the package if the food is to be cooked in the package. Parts of the food which are not intended to be eaten shall be removed and discarded. The remainder shall be homogenised and analysed for migration. The analytical results shall always be expressed on the basis of the food mass that is intended to be eaten, in contact with the food contact material.
The specific migration is analysed in the food using an analytical method in accordance with the requirements of Article 11 of Regulation (EC) No 882/2004.
In case there is evidence linked to the food sample that a substance partially or wholly originates from a source or sources other than the material or article for which the test is being carried out, the test results shall be corrected for the amount of that substance originating from the other source or sources before comparing the test results to the applicable specific migration limit.
Verification of compliance of migration into foods with the migration limits shall be carried out under the most extreme conditions of time and temperature foreseeable in actual use taking into account paragraphs 1.4, 2.1.1, 2.1.6 and 2.1.7.
Verification of compliance of migration into food simulants with the migration limits shall be carried out using conventional migration tests according to the rules set out in paragraphs 2.1.1 to 2.1.7.
The material or article shall be treated as described by accompanying instructions or by provisions given in the declaration of compliance.
Migration is determined on the material or article or, if this is impractical, on a specimen taken from the material or article, or a specimen representative of this material or article. For each food simulant or food type, a new test specimen is used. Only those parts of the sample which are intended to come into contact with foods in actual use shall be placed in contact with the food simulant or the food.
Materials and articles intended for contact with all types of food shall be tested with food simulant A, B and D2. However, if substances that may react with acidic food simulant or foods are not present testing in food simulant B can be omitted.
Materials and articles intended only for specific types of foods shall be tested with the food simulants indicated for the food types in Annex III.
The sample shall be placed in contact with the food simulant in a manner representing the worst of the foreseeable conditions of use as regard contact time in Table 1 and as regard contact temperature in Table 2.
By way of derogation to the conditions set out in Tables 1 and 2, the following rules apply:
If it is found that carrying out the tests under the combination of contact conditions specified in Tables 1 and 2 causes physical or other changes in the test specimen which do not occur under worst foreseeable conditions of use of the material or article under examination, the migration tests shall be carried out under the worst foreseeable conditions of use in which these physical or other changes do not take place;
if the material or article during it intended use is subjected only to precisely controlled time and temperature conditions in food processing equipment, either as part of food packaging or as part of the processing equipment itself, testing may be done using the worst foreseeable contact conditions that can occur during the processing of the food in that equipment;
if the material or article is intended to be employed only for hot-fill conditions, only a 2-hour test at 70 °C shall be carried out. However, if the material or article is intended to be used also for storage at room temperature or below, the test conditions set out in Tables 1 and 2 of this Section or in Section 2.1.4 of this Chapter apply depending on the duration of storage.
if the plastic material or article intended to come into contact with food of which the compliance must be verified becomes in its final application part of a food processing equipment or an appliance, or a part thereof, the migration tests may be carried out by determining the specific migration into the food or food simulant produced or processed by the whole equipment or appliance, or the part thereof, as appropriate, subject to the following conditions:
the food or food simulant is processed during testing by the equipment or part thereof in accordance with the worst foreseeable conditions that can be achieved if the equipment or its part is operated in accordance with its operating instructions, and
the migration from parts used for storage such as from reservoirs, containers, or capsules or pads which are part of the equipment during the processing of the food, is determined using conditions representative for their use, unless the applied testing conditions for the whole tested equipment or appliance are representative also of their use.
When migration testing is done under the above conditions, and the transfer of constituents from the equipment or appliance as a whole does not exceed the migration limits, the plastic parts or materials present in the equipment or appliance shall be considered to comply with Article 11(1).
The testing of the parts used for storage or supply such as reservoirs, containers, capsules or pads shall be under conditions representative of their use, and shall include the foreseeable storage conditions of the food in these parts.
The supporting documentation referred to in Article 16 shall clearly document the testing on the whole food processing and/or food producing equipment or appliance, or on parts thereof. It shall demonstrate that the testing was representative of its foreseeable use, and shall indicate for which substances migration testing was carried out and provide all testing results. The manufacturer of individual plastic parts shall ensure the absence of migration for substances for which the Regulation specifies that their migration shall not be detectable at a specified level of detection in accordance with Article 11(4).
Compliance documentation supplied in accordance with the Regulation to the producer of the final equipment or appliance, or part thereof, shall list all substances subject to migration limits that might be exceeded under the foreseeable use of the supplied part or material.
When the result is not in compliance with the Regulation it shall be determined whether the source of the non-compliance is a plastic part subject to the Regulation or a part made from another material not subject to the Regulation on the basis of documentary evidence or analytical testing. Without prejudice to Article 3 of Regulation (EU) No 1935/2004, non-compliance to the Regulation shall only be established if the migration originates from a plastic part.
If the testing conditions representative for the worst foreseeable conditions of intended use of the material or article, are not technically feasible in food simulant D2, migration tests shall be done using ethanol 95 % and isooctane. In addition a migration test shall be done using food simulant E if the temperature under the worst foreseeable conditions of intended use exceeds 100 °C. The test that results in the highest specific migration shall be used to establish compliance with this Regulation.
Contact time in worst foreseeable use | Time to be selected for testing
t ≤ 5 min | 5 min
5 min < t ≤ 0,5 hour | 0,5 hour
0,5 hours < t ≤ 1 hour | 1 hour
1 hour < t ≤ 2 hours | 2 hours
2 hours < t ≤ 6 hours | 6 hours
6 hours < t ≤ 24 hours | 24 hours
1 day < t ≤ 3 days | 3 days
3 days < t ≤ 30 days | 10 days
Above 30 days | See specific conditions
[This temperature shall be used only for food simulants D2 and E. For applications heated under pressure, migration testing under pressure at the relevant temperature may be performed. For food simulants A, B, C or D1 the test may be replaced by a test at 100 °C or at reflux temperature for duration of four times the time selected according to the conditions in Table 1.]
Worst foreseeable contact temperature | Contact temperature to be selected for testing
T ≤ 5 °C | 5 °C
5 °C < T ≤ 20 °C | 20 °C
20 °C < T ≤ 40 °C | 40 °C
40 °C < T ≤ 70 °C | 70 °C
70 °C < T ≤ 100 °C | 100 °C or reflux temperature
100 °C < T ≤ 121 °C | 121 °C
121 °C < T ≤ 130 °C | 130 °C
130 °C < T ≤ 150 °C | 150 °C
150 °C < T < 175 °C | 175 °C
175 °C < T ≤ 200 °C | 200 °C
T > 200 °C | 225 °C
For contact times above 30 days (long term) at room temperature and below, the specimen shall be tested in accelerated test conditions at elevated temperature for a maximum of 10 days at 60 °C [When testing at these accelerated test conditions the test specimen shall not undergo any physical or other changes compared to the real conditions of use, including a phase transition of the material.].
Testing for 10 days at 20 °C shall cover all storage times at frozen condition. This test can include the freezing and defrosting processes if labelling or other instructions ensure that 20 °C is not exceeded and the total time above – 15 °C does not exceed 1 day in total during the foreseeable intended use of the material or article.
Testing for 10 days at 40 °C shall cover all storage times at refrigerated and frozen conditions including hot-fill conditions and/or heating up to 70 °C ≤ T ≤ 100 °C for maximum t = 120/2^((T-70)/10) minutes.
Testing for 10 days at 50 °C shall cover all storage times of up to 6 months at room temperature, including hot-fill conditions and/or heating up to 70 °C ≤ T ≤ 100 °C for maximum t = 120/2^((T-70)/10) minutes.
Testing for 10 days at 60 °C shall cover storage above 6 months at room temperature and below, including hot-fill conditions and/or heating up to 70 °C ≤ T ≤ 100 °C for maximum t = 120/2^((T-70)/10) minutes.
For storage at room temperature the testing conditions can be reduced to 10 days at 40 °C if it is shown by scientific evidence that migration of the respective substance in the polymer has reached equilibration under this test condition.
For worst foreseeable conditions of intended use not covered by the test conditions set out in points (a) to (e), the testing time and temperature conditions shall be based on the following formula:
t2 = t1 * Exp (9627 * (1/T2 – 1/T1))
t1 is the contact time
t2 is the testing time
T1 is the contact temperature in Kelvin. For room temperature storage this is set at 298K (25 °C). For refrigerated conditions it is set at 278K (5 °C). For frozen storage it is set at 258 K (– 15 °C).
T2 is the testing temperature in Kelvin.
If a material or article is intended for different applications covering different combinations of contact time and temperature the testing shall be restricted to the test conditions which are recognised to be the most severe on the basis of scientific evidence.
If the material or article is intended for a food contact application where it is successively subject to a combination of two or more times and temperatures, the migration test shall be carried out subjecting the test specimen successively to all the applicable worst foreseeable conditions appropriate to the sample, using the same portion of food simulant.
If the material or article is intended to come into repeated contact with foods, the migration test shall be carried out three times on a single sample using another portion of food simulant on each occasion. Compliance of the material or article shall then be verified on the basis of the level of the specific migration observed in the third migration test and on the basis of the stability of the material or article. The specific migration observed in the second migration test shall not exceed the level observed in the first test, and the specific migration in the third test shall not exceed the level observed in the second test.
For the purpose of the first paragraph, the sample shall be considered non-compliant if:
mc,3 >SML, or,
mc,1 < mc,2, or,
mc,2 < mc,3, or,
mc,1 < mc,3,
where mc,1, mc,2, and mc,3 are respectively the mc during the first, the second and the third migration test carried out in accordance with the first subparagraph.
The compliance with the SML and the stability rule shall be evaluated applying the following criteria:
If (mc,3 – SML)/[(u(mc,3)] > 1,64, then the third migration is higher than the SML,
If (mc,2 – mc,1)/[(u(mc,2) + u(mc,1)] > 1,64, then the first migration is smaller than the second migration,
If (mc,3 – mc,2)/[(u(mc,3) + u(mc,2)] > 1,64, then the second migration is smaller than the third migration,
If (mc,3 – mc,1)/[(u(mc,3) + u(mc,1)] > 1,64, the first migration is smaller than the third migration.
In case mc is smaller than RL × SML, the mc shall be considered equal to RL × SML. This mc shall be used for determining the corresponding standard measurement uncertainty of the mc and for evaluating the compliance with the performance criteria set out in this point.
However, if there is scientific proof that the level of the specific migration is not increasing as described in the second paragraph above in the course of the second and third migration tests and if the SML is not exceeded during the first migration test, the material or article is considered compliant with the SML laid down in this Regulation.
Irrespective of the above rules, a material or article shall never be considered to comply with this Regulation where in any of the migration tests a substance that is prohibited from migrating or from being released in detectable quantities under Article 11(4) of this Regulation is detected.
At the end of the prescribed contact time, the specific migration is analysed in the food or food simulant using an analytical method in accordance with the applicable performance criteria laid down in this Annex.
For substances which are unstable in food simulant or food or for which no adequate analytical method is available it is indicated in Annex I that verification of compliance shall be undertaken by verification of residual content per 6 dm2 of contact surface. For materials and articles between 500 ml and 10 l the real contact surface is applied. For materials and articles below 500 ml and above 10 l as well as for articles for which it is impractical to calculate the real contact surface the contact surface is assumed to be 6 dm2 per kg food.
To screen if a material or article complies with the migration limits any of the following approaches can be applied which are considered at least as severe as the verification method described in section 2.1.
To screen for specific migration of non-volatile substances, determination of overall migration under test conditions at least as severe as for specific migration can be applied.
To screen for specific migration the migration potential can be calculated based on the residual content of the substance in the material or article assuming complete migration.
To screen for specific migration, the migration potential can be calculated based on the residual content of the substance in the material or article applying generally recognised diffusion models based on scientific evidence that are constructed in a way that must never underestimate real levels of migration.
To screen for specific migration, food simulants can be replaced by substitute food simulants if it is based on scientific evidence that the substitute food simulants result in migration that is at least as severe as migration that would be obtained using the food simulants specified in Section 2.1.2.
If the material or article is intended for a food contact application where it is successively subject to two or more time and temperature combinations, a single migration contact test time can be defined based on the highest contact test temperature from Section 2.1.3 and/or 2.1.4 by using the equation as described in point (f) of Section 2.1.4. The reasoning justifying that the resulting single test is at least as severe as the combined time and temperature combinations shall be documented in the supporting documentation provided for in Article 16.
Overall migration testing shall be performed under the standardised testing conditions set out in this chapter.
The overall migration test for materials and articles intended for the food contact conditions described in column 3 of Table 3 shall be performed for the time specified and at the temperature specified in column 2. For test OM5 the test can be performed either for 2 hours at 100 °C (food simulant D2) or at reflux (food simulant A, B, C, D1) or for 1 hour at 121 °C. The food simulant shall be chosen in accordance with Annex III.
If it is found that carrying out the tests under the contact conditions specified in Table 3 causes physical or other changes in the test specimen which do not occur under worst foreseeable conditions of use of the material or article under examination, the migration tests shall be carried out under the worst foreseeable conditions of use in which these physical or other changes do not take place.
Column 1 | Column 2 | Column 3
Test number | Contact time in days [d] or hours [h] at Contact temperature in [°C] for testing | Intended food contact conditions
OM0 | 30 min at 40 °C | Any food contact at cold or ambient temperatures and for a short duration (≤ 30 minutes).
OM1 | 10 d at 20 °C | Any food contact at frozen and refrigerated conditions
OM2 | 10 d at 40 °C | Any long-term storage at room temperature or below, including when packaged under hot-fill conditions, and/or heating up to a temperature T where 70 °C ≤ T ≤ 100 °C for a maximum of t = 120/2^((T-70)/10) minutes.
OM3 | 2 h at 70 °C | Any food contact conditions that include hot-fill and/or heating up to a temperature T where 70 °C ≤ T ≤ 100 °C for maximum of t = 120/2^((T-70)/10) minutes, which are not followed by long-term room temperature or refrigerated storage.
OM4 | 1 h at 100 °C or at reflux | High temperature applications for all types of food at temperature up to 100 °C.
OM5 | 2 h at 100 °C or at reflux or alternatively 1 h at 121 °C | High temperature applications up to 121 °C.
OM6 | 4 h at 100 °C or at reflux | Any food contact conditions at a temperature exceeding 40 °C, and with foods for which point 4 of Annex III assigns simulants A, B, C or D1.
OM7 | 2 h at 175 °C | High temperature applications with fatty foods exceeding the conditions of OM5.
Test OM 7 covers also food contact conditions described for OM0, OM1, OM2, OM3, OM4, OM5. It represents the worst case conditions for fatty food simulants in contact with non-polyolefins. In case it is technically not feasible to perform OM 7 with food simulant D2 the test can be replaced as set out in paragraph 3.2.
Test OM 6 covers also food contact conditions described for OM0, OM1, OM2, OM3, OM4 and OM5. It represents worst case conditions for food simulants A, B and C in contact with non-polyolefins.