The installation of a process-integrated gas turbine will increase energy efficiency. The integrated gas turbine works as follows. Primarily, the gas turbine drives a generator. In a heat exchanger, the exhaust gases of the gas turbine directly heat the crude oil to process temperature (375 °C). Subsequently, the remaining heat in the exhaust gases is used to generate steam for the refinery. By directly heating the crude oil to a high temperature, a very high level of efficiency is obtained. The new installation will replace 40 % of the heating (to process temperature) capacity of crude oil, will replace 10 % of steam production and will produce 70 MW of extra electricity. Implementation of the project will not result in an increase in distillation capacity.