, Decision_act (EU) 1997/873

In force
–

according to internal procedures, these three full transport containers should have been properly labelled and sealed in order to indicate clearly that they contained nuclear material and were not empty. Also, the transfer to that storage area should have been registered in the plant computer. In this case however, seals were correctly applied but no labels were attached on the transport containers and also the transfer to that storage area was not booked in,

–

as a result, the three full transport containers stood in the same room as the empty containers, and this was also the room from where shipments of empty containers were organized. The three abovementioned full containers could therefore only be distinguished from the empty one by the existence of a tiny seal; otherwise the outward appearance was identical,

–

during this time a control of the physical existence of articles containing nuclear material was carried out in accordance with internal control procedures. This control revealed that the six drums in question were missing from the process area. Thereupon the employee in charge deleted all six items from the inventory list, an action for which he had the appropriate access rights. He did not report his findings any further,

–

when a routine return shipment of 150 containers with empty drums to GE was prepared on 20 January 1997, it passed unnoticed that three of these containers were not empty. The internal procedures required a radiological check of each container but this measurement action of the operator did not reveal the presence of any nuclear material. It was not noticed that the phenomenon of sealed containers without labels was a procedurally incorrect situation, and the seal number on the seals were not checked or reported,

–

the three filled containers were shipped together with the empty ones to GE on 5 February 1997.

–

following receipt of them, on 7 March 1997 GE noticed that some of the containers were not empty and notified Enusa of its findings. Enusa started an immediate investigation; a first result confirmed the existence of a shipment error,

–

on 8 March 1997 Enusa notified the Safeguards Directorate of the Commission of the occurrence,

–

on 19 March 1997 Enusa submitted to the Safeguards Directorate of the Commission a special report as provided for by Article 4 (2) of the Particular Safeguards Provisions.

II.

LEGAL ASSESSMENT

A. The legal provisions