Table 1
Parameters and Circumstances for Check Monitoring
PART IV
Table 2
Annual Sampling Frequencies: Water Supply Zones
Regulation 9
Table 3
Annual Sampling Frequencies: Treatment Works or Supply Points
Regulation 9
Table 1
Parameters and Circumstances for Check Monitoring
PART IV
Table 2
Annual Sampling Frequencies: Water Supply Zones
Regulation 9
Table 3
Annual Sampling Frequencies: Treatment Works or Supply Points
Regulation 9
The Water Supply (Water Quality) (Amendment) Regulations 201667Law
In Schedule 3 to the 2010 Regulations— (a) in Table 2 (annual sampling frequencies: water supply zones) under the “subject to audit monitoring” heading— (i) insert in the appropriate place — Radon(b) | | | | (ii) for the entries …
(1) | (2) | (3)
Item | Parameter | Circumstances
1 | Aluminium | When used as flocculant or where the water originates from, or is influenced by, surface waters
2 | Ammonium |
3 | Clostridium perfringens (including spores) | Where the water originates from, or is influenced by, surface waters
4 | Coliform bacteria |
5 | Colony counts |
6 | Colour |
7 | Conductivity |
8 | Escherichia coli (E coli) |
9 | Hydrogen ion |
10 | Iron | When used as flocculant or where the water originates from, or is influenced by, surface waters
11 | Manganese | Where the water originates from, or is influenced by, surface waters
12 | Nitrate | When chloramination is practised
13 | Nitrite | When chloramination is practised
14 | Odour |
15 | Taste |
16 | Turbidity |
Note: This table sets out the annual sampling frequencies for all the substances and parameters in column 1. These are determined for each water supply zone according to its estimated population (column 2). The number of samples is either the standard number in column 4 or the reduced number in column 3 (if one is given). Regulation 9 provides for the circumstances in which the reduced number of samples may be taken.
1 Where the population is not an exact multiple of 5,000, the population figure should be rounded up to the nearest multiple of 5,000.
2 Sampling for these parameters may be within water supply zones or at supply points as specified in Table 3, subject to notes (iii) and (iv) below.
3 Check monitoring in water supply zones is required only where chloramination is practised. In other circumstances audit monitoring is required.
4 Audit monitoring in water supply zones is required only where sodium hypochlorite is added after water has left the treatment works. In other circumstances, audit monitoring is required at supply points.
5 …
(1) | (2) | (3) | (4)
Substances and parameters subject to check monitoring | Estimated population of water supply zone | Reduced | Standard
Subject to check monitoring | | |
E coli | <100 | | 4
Coliform bacteria | ≥100 | | 12 per 5,000 population1
Residual disinfectant | | |
Aluminium |
<100
100—4,999
5,000—9,999
10,000—29,999
30,000—49,999
50,000—79,999
80,000—100,000
1
2
6
12
18
26
38
2
4
12
24
36
52
76
Ammonium
Clostridium perfringens (including spores)2
Colony counts
Colour
Conductivity2
Hydrogen ion
Iron
Manganese
Nitrate 3
Nitrite 3
Odour
Taste
Turbidity
Subject to audit monitoring | | |
Aluminium |
<100
100—4,999
5,000—100,000
1
4
8
Antimony
Arsenic
Benzene2
Benzo(a)pyrene
Boron2
Bromate 4
Cadmium
Chromium
Clostridium perfringens (including spores)
Copper
Cyanide2
1,2 dichloroethane2
Enterococci
Fluoride2
Iron
Lead
Manganese
Mercury2
Nickel
Nitrate 3
Nitrite 3
Pesticides and related products 2
Polycyclic aromatic hydrocarbons
Radon(b)
Selenium
Sodium
Trichloroethene /Tetrachloroethene2
Tetrachloromethane2
Trihalomethanes
Chloride2
Sulphate2
Total organic carbon2
Tritium2
Indicative dose (for radioactivity)(b)
Note 1: Sampling is at treatment works for the substances and parameters shown in column (1) of the Table as items (1) to (6) and at supply points for the other substances and parameters, except nitrate subject to footnotes (ii) and (ii)(a) to the Table below. Note 2: This table sets out the annual sampling frequencies for all the substances and parameters in column 2 at treatment works or supply points. The frequencies are determined according to the volume of water supplied at each treatment works or supply point (column 3). The number of samples is either the standard number in column 5 or the reduced number in column 4 (if one is given). Regulation 9 provides for the circumstances in which the reduced number of samples may be taken.
1 Sampling at treatment works when chloramination is practised.
2 Check monitoring is required only in respect of surface waters (see regulation 6(2) and Table 1 in Schedule 3).
3 Audit monitoring at supply points is required only where sodium hypochlorite is not added after water has left the treatment works. In other circumstances, audit monitoring is required in water supply zones.
4 Sampling at treatment works when chloramination is not practised.
5…
(1) | (2) | (3) | (4) | (5)
Item | Substances and parameters | Volume of water supplied m3/d | Reduced | Standard
1. | E Coli |
<20
20—1,999
2,000—5,999
6,000—11,999
≥12,000
—
12
52
104
104
4
52
104
208
365
2. | Calliform bacteria
3. | Colony counts
4. | Nitrite 1
5. | Residual disinfectant
6. | Turbidity
Subject to check monitoring
7. | Clostridium perfringens2 |
<20
20—999
1,000—1,999
2,000—5,999
6,000—9,999
10,000—15,999
16,000—32,999
33,000—49,999
50,000—67,999
68,000—84,999
85,000—101,999
102,000—119,999
120,000—241,999
242,000—484,999
485,000—728,999
—
2
6
12
18
26
52
78
104
130
156
183
365
730
1,095
2
4
12
24
36
52
104
156
208
260
312
365
730
1,460
2,190
8. | Conductivity
Subject to audit monitoring
9. | Benzene |
<20
20—999
1,000—49,999
50,000—89,999
90,000—299,999
300,000—649,000
≥650,000
1
4
8
12
24
36
48
10. | Boron
11. | Bromate 3
11A. | Clostridium perfringens (including spores)
12. | Cyanide
13. | 1,2 dichloroethane
14. | Fluoride
15. | Mercury
16. | Nitrite 4
17. | Pesticides and Related products
17A | Radon
18. | Trichloroethene
Tetrachloroethene
19. | Tetrachloromethane
20. | Chloride
21. | Sulphate
22. | Total organic carbon
23. | Tritium
24. | Indicative dose (for radioactivity)(b)
25. |