ANNEX V, Directive (EU) 2026/706

In forcesince 11 Mar 2026

Annex VI to Directive 2014/32/EU is amended as follows:

(1)

the part ‘DEFINITIONS’ is amended as follows:

(a)

the first paragraph is replaced by the following:

‘A thermal energy meter is an instrument designed to measure the energy which in a heat-exchange circuit is absorbed (cooling) and/or given off (heating) by a liquid called the thermal energy-conveying liquid.’;

(b)

in the table, the fourth row is replaced by the following:

‘Δθ | = | the temperature difference θin – θοut with Δθ ≥ 0 for heating and Δθ ≤ 0 for cooling;’

(2)

the part ‘SPECIFIC REQUIREMENTS’ is amended as follows:

(a)

point 1.1 is replaced by the following:

‘1.1. For the temperature of the liquid: θmax, θmin,

for the temperature differences: Δθmax, Δθmin, subject to the following restrictions:

Δθmax / Δθmin ≥ 10

with the exception of cooling applications;

Δθmin is a whole number in the range of 1 K and 10 K.’;

(b)

point 1.3 is replaced by the following:

‘1.3. For the flow rates of the liquid: qs, qp, qi, where the values of qp and qi are subject to the following restriction: qp / qi ≥ 5.’.