ANNEX I, Regulation (EU) 2025/1871

In forcesince 23 Jul 2025

Annex I to Delegated Regulation (EU) 2017/79 is amended as follows:

(1)

point 1.1.4. is replaced by the following:

‘1.1.4. Position determination: The eCall system or representative arrangement shall be able to determine accurately the up-to-date vehicle location, including two recent vehicle locations before the generation of the data for the MSD.’;

(2)

in point 2.2.4., the following sentence is added:

‘Any such agreement shall be documented in the test report.’;

(3)

point 2.4.2. is replaced by the following:

‘2.4.2. The performance requirements shall be verified by performing a test eCall using the power source subjected to the high-severity deceleration.’;

(4)

in point 2.4.3. the introductory phrase is replaced by the following:

‘2.4.3. Before performing the test eCall, ensure that:’;

(5)

point 2.4.3.(c) is replaced by the following:

‘(c) one of the connection procedures defined in point 2.7, as agreed between the technical service and the manufacturer, shall be applied for any test eCall;’;

(6)

point 2.4.4. is replaced by the following:

‘2.4.4. Perform a test eCall by applying a trigger according to the instructions of the manufacturer.’;

(7)

point 2.4.5.(c) is replaced by the following:

‘(c) Verify that the MSD contained an accurate, up-to-date location. This shall be verified in accordance with the Positioning Test Procedure as specified in point 2.5 by a test record showing that the deviation between IVS location and true location, d_IVS, is less than 150 metres and the confidence bit transmitted to the PSAP test point indicates ‘position can be trusted’.

(d)

Verify that the MSD contained the two recent locations before the generation of the data for the MSD. This shall be verified by a record of the PSAP test point showing that it received the ‘recentVehicleLocationN1’ and ‘recentVehicleLocationN2’.;’

(8)

point 2.4.6. is replaced by the following:

‘2.4.6. Clear down the test eCall using the appropriate PSAP test point command (e.g. hang up).’;

(9)

points 2.7.1.1. and 2.7.1.2. are replaced by the following:

‘2.7.1.1. It shall be ensured that an emergency call emitted by the 112-based system will be performed over-the-air via a non-public (i.e. simulated) mobile network and routed to the dedicated PSAP test point.

2.7.1.2. The dedicated PSAP test point during the test procedures shall be a PSAP simulator under the control of the technical service, compliant with the applicable EN standards and certified in accordance with EN 16454 and EN 17240. It shall be equipped with an audio interface to allow voice communication tests.’;

(10)

points 2.7.2.1., 2.7.2.2. and 2.7.2.3. are replaced by the following:

‘2.7.2.1. It shall be ensured that a regular call to a long number is emitted by the 112-based eCall in-vehicle system (instead of an emergency call) and is performed over-the-air via a public mobile network and routed to the dedicated PSAP test point.

In case where this procedure is technically not possible, an emergency call emitted by the 112-based eCall in-vehicle system via a public mobile network in packet-switched domain can be used instead, if agreed by the manufacturer or technical service with the genuine PSAP or if a technical solution has been set up to route the eCall to a dedicated PSAP test point.

2.7.2.2. The dedicated PSAP test point during the test procedures shall be a PSAP simulator under the control of the technical service, compliant with the applicable EN standards and certified in accordance with EN 16454 and EN 17240. It shall be equipped with an audio interface to allow voice communication tests.

2.7.2.3. If applicable, it shall be ensured that a regular call emitted by the TPS system will be performed over-the-air via a public mobile network and routed to the TPSP test point.’;

(11)

points 2.7.3.1., 2.7.3.2. and 2.7.3.3. are replaced by the following:

‘2.7.3.1. It shall be ensured that an emergency call emitted by the 112-based system will only be performed via a wired connection with a dedicated network simulator (bypassing any mobile network antenna) and routed to the dedicated PSAP test point.

2.7.3.2. The dedicated PSAP test point during the test procedures shall be a PSAP simulator under the control of the technical service, compliant with the applicable EN standards and certified in accordance with EN 16454 and EN 17240. It shall be equipped with an audio interface to allow voice communication tests.

2.7.3.3. If applicable, it shall be ensured that a regular call emitted by the TPS system will be performed via a wired connection with a dedicated network simulator (bypassing any mobile network antenna) and routed to the dedicated TPSP test point.’;

(12)

point 2.8.1. is replaced by the following:

‘These procedures shall apply for the purposes of type-approval of a 112-based eCall in-vehicle system component in accordance with Article 6 of this Regulation.’;

(13)

point 2.8.2.2. is replaced by the following:

‘2.8.2.2. The performance requirements shall be verified by performing a test eCall according to paragraphs 2.4.3 to 2.4.6.’;

(14)

points 2.8.2.3, 2.8.2.4, 2.8.2.5 and 2.8.2.6 are deleted.