The EU Ecolabel criteria target the best performance coatings and related products on the market, in terms of environmental performance. The criteria focus on the main environmental impacts associated with the life cycle of these products and promote circular economy aspects.
For the EU Ecolabel to be awarded to a specific product, the product shall comply with each requirement. The applicant shall provide a written confirmation stating that all the criteria are fulfilled.
Specific assessment and verification requirements are indicated within each criterion.
Where the applicant is required to provide declarations, documentation, analyses, test reports, or other evidence to show compliance with the criteria, these may originate from the applicant and/or their supplier(s) as appropriate.
Competent bodies shall preferentially recognise attestations that are issued by bodies accredited in accordance with the relevant harmonised standard for testing and calibration laboratories, and verifications by bodies that are accredited in accordance with the relevant harmonised standard for bodies certifying products, processes, and services.
Where appropriate, test methods other than those indicated for each criterion may be used if the competent body assessing the application accepts their equivalence.
Where appropriate, competent bodies may require supporting documentation and may carry out independent verifications or site inspections to check compliance with these criteria.
Changes in suppliers and production sites pertaining to products to which the EU Ecolabel has been awarded shall be notified to competent bodies, together with supporting information to enable verification of continued compliance with the criteria.
As pre-requisite, the product shall meet all respective legal requirements of the country or countries in which the product is intended to be placed on the market. The applicant shall declare the product’s compliance with this requirement.
The following information shall be provided together with the application for the EU Ecolabel:
A list of all individual paint and varnish products covered by the EU Ecolabel application, grouped into product families and indicating any relevant product characteristics that affect which specific requirements from the EU Ecolabel criteria would apply. A family of products will all have the same base formulation and product subcategory, but may differ in terms of shade and/or packaging format.
A description of the product formulation(s), with a % composition of the ingredients used and the specific function of each ingredient (the composition information may be subject to a non-disclosure agreement between the applicant and the competent body or, in some cases, directly between the supplier and the competent body). Ingredient functions shall be either: accelerator; additive; anti-blocking agent; anti-foaming agent; anti-settling agent; anti-skinning agent; binder; coalescing agent; colourant-dyestuff; colourant-pigment; crosslinking agent; curing agent/hardener; diluent; dispersing agent; drier; filler; dry-film preservative; in-can preservative; matting agent; neutralising agent; optical brightener; plasticiser; polymer dispersion; preservative stabiliser; resin; retarder; rheological modifier; silicone resin; solvent; surfactant; UV stabiliser; water; water-repelling agent or, in case none of these apply, ‘other’.
Safety data sheets for the ingredients used in the paint and varnish formulations.
Any other information associated with the production of ingredients and materials that is necessary for demonstrating compliance with the EU Ecolabel criteria shall be provided by the suppliers or producers of those ingredients and materials.
In order to help determine the number of products within any given family of products, a description of the packaging format(s) used, the volume(s) of product held and the packaging material(s) used for each of the paint and varnish products covered by the EU Ecolabel application.
In order to reduce the quantity of testing and documentation required for assessment and verification procedures, several criteria explicitly state that compliance of an entire family of products can be assumed if the worst-case product can be shown to comply. Each time data for a worst-case product is submitted, it shall be accompanied by an explanation of why this particular product represents the worst-case within its family of products for the property being tested.
If the final product contains more than 3,0 % w/w of titanium dioxide (TiO2) pigment, the emissions to air and water from the production of any titanium dioxide pigment used shall meet the relevant requirements listed below for the respective production processes:
[Point sources for emissions of dust to air from the chloride process are considered as: milling, chlorination, oxidation and micronisation stages. Point sources for emissions of HCl to air from the chloride process are considered as: chlorination, acid scrubber from solid separation and metal chloride treatment processes. Point sources for emissions of dust to air from the sulphate process are considered as: milling, digestion, calcination and micronisation stages. Point sources for emissions of SO2 to air from the sulphate process are considered as: digestion and calcination processes.] [When ore used is > 95 % TiO2 content.] [When ore used is 90-95 % TiO2 content.] [When ore used is < 90 % TiO2 content.]
Parameter and analytical method | Sulphate process | Chloride process
Emissions of dust to air (measured with the relevant European or international standards) | ≤ 0,40 kg/t TiO2 pigment | ≤ 0,66 kg/t TiO2 pigment
Emissions of SO2 to air (measured with the relevant European or international standards) | ≤ 4,5 kg/t TiO2 pigment | n/a
Emissions of HCl to air (measured with the relevant European or international standards) | n/a | ≤ 0,70 kg/t TiO2 pigment
Emissions of SO42- to water (measured with the relevant European or international standards) | ≤ 300 kg SO42-/t TiO2 pigment | n/a
Emissions of Cl- to water (measured using the mass balance method or with the relevant European or international standards) | n/a |
≤ 103 kg Cl-/t TiO2 pigment
≤ 179 kg Cl-/t TiO2 pigment
≤ 329 kg Cl-/t TiO2 pigment
Low dust working environment | To be demonstrated | To be demonstrated
Emissions to air shall be counted from the relevant point source(s) stated in point (1) above where emissions can be continuously or periodically monitored from a fixed sampling point after any exhaust gas abatement system(s).
Emissions to water shall be considered as sulphate or chloride present in any treated wastewater effluent that is discharged into any rivers, lakes, transitional waters, coastal waters or seawaters.
The relevant limit for chloride emissions to water shall be based on the weighted average % TiO2 content of ore(s) used during the calculation period.
A low dust working environment shall, as a minimum, include the follows aspects:
A risk assessment for the workplace that identifies all the main areas of potential dust emission and worker exposure to dust.
The need to have in place an occupational hygiene workplace monitoring program.
Provision of appropriate training to employees about good practice for dust control.
Provision of adequate personal protective equipment to employees and visitors.
Assessment and verification
The applicant shall declare the content of TiO2 used in each of the product formulations subject to the EU Ecolabel license application. For any products with more than 3,0 % w/w TiO2 pigment content, the applicant shall also declare the supplier or suppliers of the TiO2 used in those products.
The applicant declaration shall be supported by declarations from their TiO2 supplier(s) (or TiO2 producer(s), if different) stating:
The type of TiO2 production process used (chloride or sulphate).
The applicable TiO2 content range of the weighted average ore in case of the chloride process.
Annual average emissions data of dust to air, SO2 to air, and SO42- to water for TiO2 produced through the sulphate process. Alternatively, average emission data of dust to air, HCl to air, and Cl- to water for TiO2 produced through the chloride process.
The declarations from TiO2 supplier(s) (or TiO2 producer(s), if different) should include the relevant European or international standards used to measure the relevant parameters listed in the Table 1.
The measures in place to ensure a low dust working environment.
The declaration from the TiO2 supplier(s) (or TiO2 producer(s), if different) shall include a basic calculation about how the annual average emissions were obtained. If the production of the supplied TiO2 pigment is non-continuous, then emission data calculations covering a shorter period than 12 months may be accepted. In cases of continuous monitoring, the annual average emission concentrations shall be derived from daily average concentrations. For periodically monitored emissions, at least 3 samples must be taken to derive the average results. Any periodic sampling must be taken during periods of stable operation that are representative of normal plant conditions for the production of the TiO2 pigments used in the EU Ecolabel paint products.
The emission calculations shall only be required to be submitted at the date of application for the EU Ecolabel. If the EU Ecolabel is awarded, the applicant can simply request updated declarations each year from their TiO2 supplier(s) of continuing compliance with the emission limits.
For emissions to air, concentrations shall be expressed in units of mg/Nm3 and multiplied by a specific emission air flow rate in units of Nm3/tonne TiO2 pigment production for the same time period that the data was collected. If there is more than one exhaust gas abatement system for major point sources of emissions to air, emissions from the clean air from each abatement system shall be counted and added.
For emissions to water, either a direct measurement or a mass balance approach shall be used. The mass balance approach shall be based on the balance between inputs of raw sulphate/chloride and outputs of sulphate/chloride in by-products, in emissions to air and in solid waste that is disposed of to landfill or incinerated. The difference in the masses of the inputs and outputs shall be considered as the mass of sulphate/chloride that is emitted to water during the calculation period and shall be divided by the estimated quantity of TiO2 pigment produced during the same period to calculate specific emissions to water in units of kg sulphate or chloride/t TiO2 pigment.
With the direct measurement approach for emissions to water, measured concentrations in units of g/m3 shall be multiplied by a specific treated wastewater effluent flow rate in units of m3/tonne TiO2 pigment production for the same time period that the sulphate/chloride data was collected.
In order to demonstrate the efficiency in use of performance coatings and related products, the following tests per type of product, as indicated in Table 2 and detailed in the criterion text later, shall be undertaken.
Criteria |
Performance coating categories
(with their subcategories identified according to the Directive 2004/42/EC)
Floor covering paints (i, j) | Floor covering varnishes (i, j) | Anti-corrosion products (i, j) | Primers (within i) and j) systems) | Binding primers (within i) and j) systems) | Waterproofing coatings (i, j)
2(a) Spreading rate
Yes | No | If opaque | If opaque | If opaque | If opaque, report only
2(b) White pigment content
Yes | No | If opaque | No | No | If opaque, report only
2(c) Resistance to water
Yes | Yes | Yes | No | No | Yes + ETA
2(d) Adhesion
If opaque and no undercoat or primer | If opaque and no undercoat or primer | If opaque and no undercoat or primer | If opaque | If opaque | If opaque and no undercoat or primer
2(e) Abrasion
Yes | Yes | If for metal flooring | No | No | If for trafficked floors
2(f) Weathering
If outdoors | If outdoors | If outdoors | No | No | If outdoors
2(g) Corrosion resistance
If claimed | No | Yes | If claimed | If claimed | If claimed
2(h) Ecotoxicity
No | No | Yes | No | No | If outdoors
Note 1: This requirement does not apply to transparent or semi-transparent coatings.
Note 2. For tinting systems, this criterion applies only to the tinting base containing the most TiO2. In cases where this tinting base is unable to achieve this requirement, the criterion shall be met after tinting the base to produce the standard colour RAL 9010.
Note 3. This requirement applies to all white paints. For families of paint products available only in preset shades, the spreading rate shall apply to the lightest colour.
Spreading rates shall be calculated while ensuring a hiding power of at least 98 % according to relevant European or international standards or an equivalent method that can be validated against them. The following minimum spreading rate limits apply:
Indoor performance coatings shall have a spreading rate of at least 8 m2 per litre of product.
Outdoor performance coatings shall have a spreading rate of at least 6 m2 per litre of product.
Performance coatings marketed for both indoor and outdoor application shall meet the higher spreading rate requirement of at least 8 m2 per litre.
Any opaque primers used in performance coating systems shall have a spreading rate of at least 8 m2 per litre of product. A lower spreading rate of 6 m2 per litre of product applies to opaque primers with specific blocking, sealing, penetrating, binding or special adhesion properties.
The applicant shall provide a declaration of compliance with the relevant spreading rate limits or a justification of non-applicability of the spreading rate requirement for each of the products covered by the EU Ecolabel application. The declaration shall be supported by test results according to relevant European or international standards or an equivalent method that can be validated against them. It shall be clearly indicated which spreading rate results correspond to which families of products covered by the EU Ecolabel license application.
Note: This criterion only applies to paint products and white pigment content shall be calculated with the same products for which spreading rate is measured as per the notes in criterion 2(a). For the purposes of this criterion, the term ‘white pigment’, shall be considered to refer only to pigments with a refractive index higher than 1,8.
The white pigment content shall not exceed:
36 g/m2 for performance coatings marketed for indoor use only.
38 g/m2 for performance coatings marketed for outdoor use only.
36 g/m2 for performance coatings marketed for both indoor and outdoor use. Any EU Ecolabel paint products that claim wet scrub resistance must meet the requirements for class 1 or class 2 according to the procedure defined in relevant European or international standards and classification systems and comply with the respective upper limits for white pigment content.
The applicant shall provide a declaration of compliance with the relevant requirement or a justification of the non-applicability of the requirements for each of the products covered by the EU Ecolabel application. In cases of relevant products, the applicant shall declare the total content of white pigments with a refractive index > 1,8 in the final product, relevant tinting base or white base paint formulations that are subject to the EU Ecolabel license application. This information shall be provided in terms of the chemical name and CAS number of the white pigment, its declared refractive index, its concentration in g/l of paint product and the density of the paint, in g/l
Note: This requirement applies to all performance coatings. In coating systems with a primer or undercoat(s), either the full coating system or just the finishing layer may be tested.
All performance coatings shall have resistance to water, as determined by relevant European or international standards, such that after 24 hours of exposure and 16 hours of recovery, no change of gloss is observed in transparent or semi-transparent coatings and no change of colour occurs in any opaque coatings.
No change of gloss or colour in exposed samples shall be considered as a visual rating of 0 when measured for quantity of defects, size of defects and intensity of changes according to the classification system of relevant European or international standards.
Additionally for waterproofing coatings, compliance with any relevant European Assessment Document (EAD) stipulations shall also be demonstrated.
The applicant shall provide a declaration of compliance with the requirement or a justification of the non-applicability of the requirement for each of the products covered by the EU Ecolabel license application.
For any applicable products included in their license application, the applicant declaration shall be supported by copies of test report(s) following relevant European or international standards that cover the licensed product or family of products, including reported results for change of gloss according to relevant European or international standards.
For waterproofing coatings, the applicant shall additionally provide a European Technical Approval (ETA) certificate that has been issued by an approved Technical Assessment Body (for example a certificate according to EAD when the product is a liquid applied roof waterproofing kit). In cases where there is no relevant EAD to follow, the applicant shall declare this and provide a technical description of the product, including compliance with any relevant European or international standards and a description of the intended uses of the product and how it should be used correctly.
Note: This criterion applies to opaque primers or undercoats for performance coatings. The adhesion test may be conducted on any opaque primer or undercoat alone, or on the primer/undercoat and finishing coat together, so long as the combination is opaque. In cases of different colour shades within a family of products, only the light-coloured or white base paint or tinting base(s), need to be tested.
Primers for exterior masonry uses shall score a pass in the pull-off test of relevant European or international standards where the cohesive strength of the substrate is less than the adhesive strength of the primer coating, otherwise the adhesion of the primer coating must be in excess of a pass value of 1,5 MPa.
Floor primers or floor undercoats shall score 2 or less in the test for adhesion of relevant European or international standards.
The applicant shall provide a declaration of compliance with the relevant requirement or a justification of the non-applicability of the requirements for each of the products covered by the EU Ecolabel application. For any opaque masonry primer, binding primer or undercoat products included in their license application, the applicant shall provide copies of test reports following relevant European or international standards, as applicable.
Note: This criterion applies to floor coatings. In cases of different colour shades within a family of products, only the light-coloured or white base paint or tinting base(s),need to be tested.
A weight loss of ≤ 70 mg shall be observed when floor coatings are exposed to 1000 test cycles with a 1000 g load and a CS10 wheel according to relevant European or international standards.
The applicant shall provide a declaration of compliance with the requirement for floor coating products included in their license application. The declaration shall be supported by copies of test reports following relevant European or international standards.
Note: This criterion applies to outdoor performance coatings. In the case of different colour shades within a family of products, only the light-coloured or white base paint or tinting base(s)need to be tested.
All outdoor performance coatings shall be exposed to artificial weathering in apparatus including fluorescent UV lamps and condensation or water spray according to relevant European or international standards. They shall be exposed to test conditions for 1000 hours with cycling conditions of: UVA 4 h/60 °C + humidity 4 h/50 °C.
Alternatively, outdoor performance coatings for wooden substrates may be exposed to weathering for 1000 hours in the QUV accelerated weathering apparatus with cyclic exposure with UV(A) radiation and spraying according to relevant European or international standards.
After weathering, the exposed films shall comply with the requirements specified in Table 3 below.
Property | Requirement (after weathering) | Scope of products covered/not covered
Colour change | Colour change, ΔΕ ≤ 4 | Not applicable to primers or intermediate coats in performance coating systems nor to transparent or semi-transparent performance coating systems
Decrease of gloss | ≤ 30 % decrease compared to initial value | Not applicable to performance coatings with initial gloss value of < 60 % at 60° angle of incidence
Chalking | A score of ≤ 2 | Only applicable to finishing coats or the full performance coating system used on outdoor masonry, wood and metal substrates.
Flaking |
Flake density: ≤ 2
Flake size: ≤ 2
Cracking |
Crack quantity: ≤ 2
Crack size: ≤ 3
Blistering |
Blister density: ≤ 3
Blister size: ≤ 3
The applicant shall provide a declaration of compliance with the relevant requirement or a justification of the non-applicability of the requirements for each of the products covered by the EU Ecolabel application. For any outdoor performance coatings included in their license application, the applicant shall provide copies of test reports that detail the weathering test method used (being in compliance with relevant European or international standards) and provide results of changes in properties after weathering, as applicable.
Note: This criterion only applies to anti-corrosion performance coatings and related products.
Anti-corrosion primers or coating systems shall be exposed to simulated corrosion stresses on the metallic substrates and use environments (for example C2, C3, C4 or C5 as per relevant European or international standards) for which their use is recommended. Corrosion stresses applied in testing shall correspond to the ‘high’ level for each category, which is as follows:
Corrosivity category | Test regime 1 | Test regime 2
Water condensation, hours | Neutral salt spray, hours | Annex B (cyclic ageing test, hours)
C2 (high) | 120 | - | -
C3 (high) | 240 | 480 | -
C4 (high) | 480 | 720 | -
C5 (high) | 720 | 1440 | 1680
After exposure, the coated surfaces shall be examined and be found to comply with the following requirements:
A rating of 3 or better (i.e. 0, 1 or 2) for size of blisters according to relevant European or international standards.