4. COMMISSION’S ASSESSMENT › 4.3. Substantive points › 4.3.3. Tests conducted by ANFR, Decision_act (EU) 2025/1760

In forcesince 19 Aug 2025
(87)

ANFR, using the services of CETECOM and carrying out measurements as set out in protocol 2, concluded that:

Prior to the software update, the iPhone 12 A2403 exceeded the limb SAR limit value as set out in harmonised standard EN 50566:2017.

After the software update, the iPhone 12 A2403 no longer exceeded the limb SAR limit value as set out in harmonised standard EN 50566:2017 when operating in cellular networks located in the French territory.