ANFR confirmed that, following the rejection of protocol 1, Apple proposed protocol 2. According to ANFR, that protocol was more in line with what is expected from a test taking into consideration the reasonably foreseeable conditions. However, by following protocol 2, ANFR noted that the limb SAR measurement performed by the accredited laboratory CETECOM showed the persistence of the non-compliance. The limit of 4 W/kg was exceeded by simulating the use of the iPhone 12 A2403 in France, more specifically, the limb SAR measured presented a retained value of 5,740 W/kg [The SAR measurement, following measurement protocol 2, carried out in August 2023.] (while the first measurement carried out presented a value of 5,615 W/kg) [The first SAR measurement that showed a retained value of 5,615 W/Kg was carried out in August 2022.]. Additional tests performed by ANFR concluded that the limb SAR exceeded the recommended value by simulating the use of the iPhone 12 in two other Member States.
43 3. ARGUMENTS OF THE PARTIES › 3.1. ANFR › 3.1.2. Substantive points, Decision_act (EU) 2025/1760