Annexes I to IV to Regulation (EU) 2019/2021 are amended and Annex IIIa is added as follows:
Annex I is amended as follows:
point 5 is replaced by the following:
‘(5) “microLED display” means an electronic display where individual pixels are lit using microscopic LED technology;’;
the following points (38), (39) and (40) are added:
‘(38) “declared values” means the values provided by the manufacturer, importer or authorised representative for the stated, calculated or measured technical parameters in accordance with Article 4, for the verification of compliance by the Member State authorities.
“HD resolution” means 1920 x 1080 pixels or 2073600 pixels;
“UHD resolution” means 3840 x 2160 pixels or 8294400 pixels.’;
Annex II , point A.1 is amended as follows:
After the last sentence before table 1, the following paragraph is added:
‘The declared values of the on mode power (Pmeasured) and screen area (A) as listed in Table 5 of Annex VI of delegated Regulation 2019/2013 shall be used for the calculation of EEI.’;
Table 1 is replaced by the following:
EEImax for electronic displays with resolution up to HD | EEImax for electronic displays with resolution above HD and up to UHD | EEImax for electronic displays with resolution above UHD and for MicroLED displays
1 March 2021 | 0,90 | 1,10 | n.a.
1 March 2023 | 0,75 | 0,90 | 0,90’
Section C is amended as follows:
The last paragraph of point 2 is replaced by the following:
‘Networked electronic displays shall comply with the requirements for networked standby mode with the reactivation trigger device connected to the network and ready to activate a trigger instruction when required to.
With networked standby mode disabled, networked electronic displays shall comply with the requirements of standby mode.’;
Section D is amended as follows:
point 1 is replaced by the following:
‘1. Design for dismantling, recycling and recovery
Manufacturers, importers or their authorised representatives shall ensure that joining, fastening or sealing techniques do not prevent the removal, using commonly available tools, of the components indicated in point 1 of Annex VII of Directive 2012/19/EU on WEEE or in Article 11 of Directive 2006/66/EC on batteries and accumulators and waste batteries and accumulators, when present.
The derogations indicated in Article 11 of Directive 2006/66/EC about permanent connection between the electronic display and the battery or accumulator apply.
Manufacturers, importers or their authorised representatives shall, without prejudice to point 1 of Article 15 of Directive 2012/19/EU, make available, on a free-access website, the dismantling information needed to access any of the products components referred to in point 1 of Annex VII of Directive 2012/19/EU.
This dismantling information shall include the sequence of dismantling steps, tools or technologies needed to access the targeted components.
This end of life information shall be available until at least 15 years after the placing on the market of the last unit of a product model.’;
in point 5, point (a)(1) is replaced by the following:
‘(1) manufacturers, importers or authorised representatives of electronic displays shall make available to professional repairers at least the following spare parts: internal power supply, connectors to connect external equipment (cable, antenna, USB, DVD and Blu-Ray), capacitors above 400 microfarads, batteries and accumulators, DVD/Blu-Ray module if applicable and HD/SSD module if applicable for a minimum period of seven years after placing the last unit of the model on the market;’;
Annex III is modified as follows:
the following paragraph is added after the first paragraph:
‘Where a parameter is declared pursuant to Article 4, its declared value shall be used by the manufacturer, importer or authorised representative for the calculations in this Annex.
In the absence of existing relevant standards and until the publication of the references of the relevant harmonised standards in the Official Journal, the transitional testing methods set out in Annex IIIa or other reliable, accurate and reproducible methods, which take into account the generally recognised state-of-the-art, shall be used.’;
at the end of the Annex, the following is inserted:
‘Measurements of Standard Dynamic Range, High Dynamic Range, screen luminance for Automatic Brightness Control, Peak White luminance ratio and other luminance measurements shall be made as detailed in Table 3a.
Notes
Pmeasured
Standard dynamic range (SDR) on-mode, “normal”
Power measurement notes
(See Annex IIIa for informative notes regarding the testing of Displays with a standardised DC input or a non-removable battery providing the primary power. For the purposes of these Transitional Measurement Methods a standardised DC input is solely one compatible with the various forms of USB power delivery.
Video Signals Notes
The 10-minute Dynamic Broadcast video sequence described in existing relevant standards shall be replaced with an updated 10-minute Dynamic Broadcast video sequence. This is available for download at: https://circabc.europa.eu/ui/group/1582d77c-d930-4c0d-b163-4f67e1d42f5b/library/23ab249b-6ebc-4f45-9b0e-df07bc61a596?p=1&n=10&sort=modified_DESC. Two files are available, in SD and HD. They are respectively titled “SD Dynamic Video Power.mp4”, and “HD Dynamic Video Power.mp4”. SD resolution is made available for the limited types of display that cannot accept or display higher resolution standards. The HD resolution file is used for all other display resolutions since this closely matches the average picture level (APL) of the current IEC HD dynamic broadcast dynamic test sequence described in existing relevant standards.
Upscaling from HD to higher native resolution shall be performed by the Unit Under Test (UUT) and not by an external device. Where upscaling has to be performed by an external device the full details of the device and the signal interface with the UUT shall be recorded.
The data signal from the downloaded file storage system to the UUT digital signal interface shall be confirmed to provide peak white and full black video levels. If the file playback system has special picture optimisation features (e.g. deep blacks or enhanced colour processing) these shall be disabled. For repeatability of measurement purposes, the details of the file storage and playback system shall be recorded as well as the type of digital interface with the UUT (e.g. HDMI, DVI etc.) The power measurement P measured is an average value from the full 10-minute length of the dynamic test sequence, taken with ABC disabled.
Pmeasured
High dynamic range (HDR)
on-mode “normal”
(auto mode switching to HDR)
No existing relevant standard is published so far.
Following the Pmeasured (SDR) dynamic test sequence measurement two HDR dynamic test sequences shall be played.
These 5-minute sequences are rendered in HD resolution only, in the common HDR standards of HLG and HDR10. Upscaling from HD to a higher native display resolution shall be performed by the UUT and not an external device. Where upscaling has to be performed by an external device the full details of the device and the signal interface with the UUT shall be recorded.
These files are available for download at: https://circabc.europa.eu/ui/group/1582d77c-d930-4c0d-b163-4f67e1d42f5b/library/38df374d-f367-4b72-93d6-3f48143ad661?p=1&n=10&sort=modified_DESC
and have identical programme content. The files are respectively titled “HDR-HLG Power.mp4” and “HDR_HDR10 Power.mp4”
It is essential that the UUT switch to the HDR display mode is confirmed in the picture settings menu before power data is logged. The integrated power measurement for each sequence (Pav) shall be summed and halved for the calculation of the label HDR energy efficiency class and label HDR power declaration.
If the UUT cannot be tested in one of these HDR formats, this shall be noted and the power declared shall be the Pav measured for the HDR format that is supported.
An ABC allowance does not apply in HDR display mode.
Pmeasured HDR = 0.5 * (Pav HLG + Pav HDR10)
If one of these HDR display modes is not supported, the measured numerical value of (Pav HLG) or (Pav HDR10) as appropriate, shall be used for Label VII and Label VIII declarations.
Screen Luminance Measurement for automatic brightness control (ABC) control characteristics evaluation and any other peak white luminance measurement requirement. |
No existing relevant standards can be used.
A new variant of the “box and outline” dynamic test pattern providing a dynamic format with colour shall be used for all peak white display luminance measurements and not the 3-bar black and white pattern.
A set of these variant dynamic test patterns, which combine the box and outline format and VESA L10 to L80 white measurement box format shall be used as described in Section 1.2.4. of Annex IIIa and are available for download at: https://circabc.europa.eu/ui/group/1582d77c-d930-4c0d-b163-4f67e1d42f5b/library/4f4b47a4-c078-49c4-a859-84421fc3cf5e?p=1&n=10&sort=modified_DESC. They are contained in the subfolders labelled SD, HD and UHD. Each subfolder contains eight peak white dynamic test patterns from L10 to L80. A resolution may be chosen according to the native resolution and signal compatibility of the UUT. The selection of a pattern with the appropriate resolution shall be based upon a) the minimum required white box dimensions for correct operation of the contact luminance measuring instrument and b) the fact that no power limiting effect exhibited by the UUT (large areas of white may result in a reduction of peak white levels). Any upscaling shall be performed by the UUT and not an external device. The data signal from the downloaded file storage system to the UUT digital signal interface shall be confirmed to provide peak white and full black video levels and have no other video enhancement processing (e.g. deep blacks / colour enhancement) Both the storage system and signal interface type shall be noted. For displays tested using a USB, or USB compatible data interface with the feature of power delivery, both the UUT and USB connected signal source shall operate from their own power source with the data path only connected..
Measurements related to ABC for “Allowances and adjustments for the purposes of the EEI calculation and functional requirements” | The methodology for ABC ambient light source set-up and luminance control as specified in existing standards shall not be used for the purposes of ABC related measurements for this regulation. The methodology to be used is detailed in Section 1.2.5. of Annex IIIa.
Peak white luminance ratio |
No existing relevant standards can be used.
The “box and outline” dynamic test pattern selected for the ABC peak white luminance measurements (Annex III.a Section 1.2.4) shall be used to measure the peak white luminance of the “normal configuration” with ABC on. If this is less than 150 cd/m2 for monitors or 220 cd/m2 for other display products, then a further measurement shall be made of the peak white luminance of the brightest pre-set configuration in the user menu (not the shop configuration). ABC need not be on for the luminance ratio measurements but the status of the ABC (on or off) shall apply to both measurements. Where ABC is on, the illuminance shall be 100lux for both measurements. Care shall be taken to ensure that the dynamic test pattern selected for peak white luminance measurement in the “normal configuration” does not cause luminance instability in the brightest pre-set configuration. A smaller peak white box pattern shall be selected for both measurements if instability occurs.
General notes |
The following test standards provide important supporting information for the specification of test equipment and the required testing conditions relevant to measurement and testing guidance given in this Annex.
EN 50564:2011
EN 50643:2018
EN 62087-1:2016
EN 62087- 2:2016
EN 62087-3:2016
EN IEC 62680 series of standards 2013 to 2020
IEC TR 63274 ED1:2020 (Advisory technical report on HDR testing requirements)’
the following Annex IIIa is inserted:
‘’
Annex IV is amended as follows:
the first paragraph is replaced by the following:
‘The verification tolerances defined in this Annex relate only to the verification by Member State authorities of the declared values and shall not be used by the manufacturer, importer or authorised representative as an allowed tolerance to establish the values in the technical documentation or in interpreting these values with a view to achieving compliance or to communicate better performance by any means.’;
the third paragraph is replaced by the following:
‘As part of verifying that a product model complies with the requirements laid down in this Regulation pursuant to Article 3(2) of Directive 2009/125/EC the authorities of the Member States shall apply the following procedure for the requirements referred to in Annex I.’;
in point 1.8, the following paragraph is added:
‘The requirements of Annex II, D.4. shall be deemed to be complied with if:
The determined value for HFRs identified in Directive 2011/65/EU does not exceed the relevant maximum concentration values defined in Annex II of Directive 2011/65/EU; and
For other HFRs, the determined value for any homogenous material does not exceed 0,1 % by weight of halogen content. Where the determined value for any homogenous material exceeds 0,1 % by weight of halogen content, the model may still be considered compliant where documentary checks or any other appropriate, reproducible methods show that the halogen content is not attributable to flame retardant.’;
in point 2, the third paragraph is replaced by the following:
‘The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model.’;
the fifth row of Table 3 is replaced by the following:
‘Visible screen diagonal in centimetres | The determined value (*) shall not be lower than the declared value by more than 1 cm’