ANNEX IV Measurement methods and calculations, Regulation (EU) 2019/2018

In forcesince 30 Sep 2023cited 2×

For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using harmonised standards, or other reliable, accurate and reproducible methods, which take into account the generally recognised state-of-the-art methods and are in line with the following provisions set out below. The reference numbers of these harmonised standards have been published for this purpose in the Official Journal of the European Union.

Where a parameter is declared pursuant to Article 3(3) of Regulation (EU) 2017/1369 and in accordance with Table 11 of Annex VI, its declared value shall be used by the supplier for the calculations in this Annex.

(a)

the ambient conditions shall correspond to Set 1, except for ice-cream freezers and gelato scooping cabinets which shall be tested in ambient conditions corresponding to Set 2, as set out in Table 2.

(b)

where a compartment can be set to different temperatures, it shall be tested at the lowest operating temperature.

(c)

refrigerated vending machines with compartments with variable volumes shall be tested with the net volume of the compartment with the highest operating temperature adjusted to its minimum net volume.

(d)

for beverage coolers, the specified cooling speed shall be according to the half reload recovery time.

Dry bulb temperature, °C | Relative humidity, % | Dew point, °C | Water vapour mass in dry air, g/kg

Set 1 | 25 | 60 | 16,7 | 12,0

Set 2 | 30 | 55 | 20,0 | 14,8

(a)

For all refrigerating appliances with a direct sales function, the EEI, expressed in % and rounded to the first decimal place, is the ratio of the AE (in kWh/a) and the reference SAE (in kWh/a) and is calculated as:

EEI = AE/SAE.

(b)

The AE, expressed in kWh/a and rounded to two decimal places, is calculated as follows:

AE = 365 × Edaily;

with:

Edaily is the energy consumption of the refrigerating appliance with a direct sales function over 24 hours, expressed in kWh/24h, rounded to three decimal places and measured according to the temperature conditions of Table 4 for the relevant temperature class.

(c)

The SAE is expressed in kWh/a and rounded to two decimal places. For refrigerating appliances with a direct sales function with all compartments having the same temperature class and for refrigerated vending machines, the SAE is calculated as follows:

SAE = 365 × P × (M + N × Y) × C;

For refrigerating appliances with a direct sales function with more than one compartment having different temperature classes, with the exception of refrigerated vending machines, the SAE is calculated as follows:

SAE365P

nc=1

MNYcCc;

where:

(1)

c is the index number for a compartment type ranging from 1 to n, with n being the total number of compartment types.

(2)

The values of M and N are given in Table 3.

Category | Value for M | Value for N

Beverage coolers | 2,1 | 0,006

Ice-cream freezers | 2,0 | 0,009

Refrigerated vending machines | 4,1 | 0,004

Gelato-scooping cabinets | 25,0 | 30,400

Vertical and combined supermarket refrigerator cabinets | 9,1 | 9,100

Horizontal supermarket refrigerator cabinets | 3,7 | 3,500

Vertical and combined supermarket freezer cabinets | 7,5 | 19,300

Horizontal supermarket freezer cabinets | 4,0 | 10,300

Roll-in cabinets (from 1 March 2021) | 9,2 | 11,600

Roll-in cabinets (from 1 September 2023) | 9,1 | 9,100

(3)

The values of C, the temperature coefficient are given in Table 4.

[For multi-temperature vending machines, TV shall be the average of TV1 (the maximum measured product temperature in the warmest compartment) and TV2 (the maximum measured product temperature in the coldest compartment), rounded to one decimal.] [category 1 = refrigerated closed fronted can and bottle machines where the products are held in stacks, category 2 = refrigerated glass fronted can and bottle, confectionery & snack machines, category 3 = refrigerated glass fronted machines entirely for perishable foodstuffs, category 4 = refrigerated multi-temperature glass fronted machines, category 6 = combination machines consisting of different categories of machine in the same housing and powered by one chiller.]

n.a = not applicable

(a)

Supermarket cabinets

Category | Temperature class |

Highest temperature of warmest M-package

(°C)

Lowest temperature of coldest M-package

(°C)

Highest minimum temperature of all M-package (°C) | Value for C

Vertical, combined supermarket refrigerator cabinets | M2 | ≤ +7 | ≥ –1 | n.a. | 1,00

H1 and H2 | ≤ +10 | ≥ –1 | n.a. | 0,82

M1 | ≤ +5 | ≥ –1 | n.a. | 1,15

Horizontal supermarket refrigerator cabinets | M2 | ≤ +7 | ≥ –1 | n.a. | 1,00

H1 and H2 | ≤ +10 | ≥ –1 | n.a. | 0,92

M1 | ≤ +5 | ≥ –1 | n.a. | 1,08

Vertical and combined supermarket freezer cabinets | L1 | ≤ –15 | n.a. | ≤ –18 | 1,00

L2 | ≤ –12 | n.a. | ≤ –18 | 0,90

L3 | ≤ –12 | n.a. | ≤ –15 | 0,90

Horizontal supermarket freezer cabinets | L1 | ≤ –15 | n.a. | ≤ –18 | 1,00

L2 | ≤ –12 | n.a. | ≤ –18 | 0,92

L3 | ≤ –12 | n.a. | ≤ –15 | 0,92

(b)

Gelato-scooping cabinets

Temperature class | Highest temperature of warmest M-package (°C) | Lowest temperature of coldest M-package (°C) | Highest minimum temperature of all M-package (°C) | Value for C

G1 | -10 | -14 | n.a. | 1,00

G2 | -10 | -16 | n.a. | 1,00

G3 | -10 | -18 | n.a. | 1,00

L1 | -15 | n.a. | -18 | 1,00

L2 | -12 | n.a. | -18 | 1,00

L3 | -12 | n.a. | -15 | 1,00

S | Special classification | 1,00

(c)

Refrigerated vending machines

Temperature class | Maximum measured product temperature (Tv) (°C) | Value for C

Category 1 | 7 | 1+(12-TV)/25

Category 2 | 12

Category 3 | 3

Category 4 | (TV1+TV2)/2

Category 6 | (TV1+TV2)/2

(d)

other refrigerating appliances with a direct sales function

Category | Value for C

Other appliances | 1,00

(4)

Coefficient Y is calculated as follows:

(a)

for beverage coolers:

Yc is the equivalent volume of the compartments of the beverage cooler with target temperature Tc, (Veqc), calculated as follows:

Yc = Veqc = GrossVolumec × ((25 - Tc)/20) × CC;

where Tc is the average compartment classification temperature of the compartment and CC is the climate class factor. The values for Tc are set out in Table 5. The values for CC are set out in Table 6.

Temperature class | Tc (°C)

K1 | +3,5

K2 | +2,5

K3 | -1,0

K4 | +5,0

Warmest ambient temperature (°C) | Ambient relative humidity (%) | CC

+25 | 60 | 1,00

+32 | 65 | 1,05

+40 | 75 | 1,10

(b)

for ice-cream freezers:

Yc is the equivalent volume of compartments of the ice-cream freezer with target temperature Tc, (Veqc), calculated as follows:

Yc = Veqc = NetVolume × ((12 - Tc)/30) × CC;

where Tc is the average compartment classification temperature of the compartment and CC is the climate class factor. The values for Tc are set out in Table 7. The values for CC are set out in Table 8.

Temperature class | Tc (°C)

Warmest M-package temperature colder or equal to in all tests (except lid opening test) (°C) | Warmest M-package maximum temperature rise allowed during the lid opening test (°C)

-18 | 2 | -18,0

-7 | 2 | -7,0

Minimum | Maximum | CC

Ambient temperature (°C) | Ambient relative humidity (%) | Ambient temperature (°C) | Ambient relative humidity (%)

Ice-cream freezer with transparent lid | 16 | 80 | 30 | 55 | 1,00

35 | 75 | 1,10

40 | 40 | 1,20

Ice-cream freezer with non-transparent lid | 16 | 80 | 30 | 55 | 1,00

35 | 75 | 1,04

40 | 40 | 1,10

(c)

for refrigerated vending machines:

Y is the net volume of the refrigerated vending machine, which is the sum of the volumes of all compartments within which the products directly available for vending are contained and the volume through which the products pass during the dispensing process, expressed in litres (L) and rounded to the nearest integer.

(d)

for all other refrigerating appliances with direct sales function:

Yc is the sum of the TDA of all compartments of the same temperature class of the refrigerating appliance with a direct sales function, expressed in square meters (m2), and rounded to two decimal places.

(5)

The values for P are set out in Table 9.

Cabinet type | P

Integral supermarket cabinets | 1,10

Other refrigerating appliances with a direct sales function | 1,00