The following indicative benchmarks are identified for the purpose of Part 3, point 2 of Annex I to Directive 2009/125/EC.
They refer to the best available technology by 7 April 2019.
The indicative benchmarks for the best available technology on the market for servers and online data storage products are as follows.
Product type | Idle power, W | Active state efficiency | Operating condition class
Tower server, 1 socket | 21,3 | 17 | A3
Rack server, 1 socket | 18 | 17,7 | A4
Rack server, 2 socket, low performance | 49,9 | 18 | A4
Rack server, 2 socket, high performance | 67 | 26,1 | A4
Rack server, 4 socket | 65,1 | 34,8 | A4
Blade server, 2 socket | 75 | 47,3 | A3
Blade server, 4 socket | 63,3 | 21,9 | A3
Resilient server, 2 socket | 222 | 9,6 | A3
Data storage products | Not applicable | Not applicable | A3
PSU nameplate power | 10 % | 20 % | 50 % | 100 %
< 750W | 91,17 % | 93,76 % |
94,72 %
Power factor > 0,95
94,14 %
≥ 750W | 95,02 % |
95,99 %
Power factor > 0,95
96,09 % | 94,69 %