4 ANNEX IIIa, Regulation (EU) 2019/424

In forcesince 1 May 2021

[This is necessary because of the wide variation of APA cards in the market and the fact that the SERT tool does not include any worklets which exercise APAs. Therefore, SERT efficiency results for servers with the expansion APA cards or other add-in cards would not be representative of the performance/power capability of the server.] [In the case of servers which are declared as being part of a server product family, point 1 of Annex IV to Regulation (EU) 2019/424 foresees that the Member State authorities can test the low-end performance configuration or the high-end performance configuration and, as per definitions 21 and 22 of Annex I, these configurations shall have all memory channels populated with the same DIMM raw card design and capacity.]

Parameter | Source | Reference Test Method / Title | Notes

Server efficiency and server performance in active state | ETSI | ETSI EN 303470:2019 | |

General notes on the testing with EN 303470: 2019:

a.

Testing shall be conducted at an appropriate EU voltage and frequency (e.g. 230v, 50Hz).

b.

Similar to the provision on expansion APA cards under point 2 of Annex III, the unit under test shall be tested with other types of add-in cards (for which no allowance is provided and not exercised in SERT testing) removed, when measuring the idle state power, the active state efficiency and server performance in active state.

c.

In the case of servers which

i.

are not declared as being part of a server product family

ii.

are as-shipped in a configuration without all memory channels populated with the same dual in-line memory modules (DIMMs)

a configuration with all memory channels populated with the same DIMMs shall be tested.

Idle state power (Pidle) | ETSI | ETSI EN 303470:2019 |

Maximum power | ETSI | ETSI EN 303470:2019 | Maximum power is the highest measured power demand reported by SERT testing under any single workload and load level.

Idle state power at the higher boundary temperature of the declared operating condition class | The Green Grid | Simplified high temperature idle power reporting for (EU) 2019/424 sert collection | The test shall be conducted at a temperature corresponding to the highest allowable temperature for the specific operating condition class (A1, A2, A3 or A4).

Power Supply Efficiency | EPRI and Ecova | Generalized Test Protocol for Calculating the Energy Efficiency of Internal AC-DC and DC-DC Power Supplies Revision 6.7 | Testing shall be conducted at an appropriate EU voltage and frequency (e.g. 230v, 50Hz).

Power Supply Power Factor | EPRI and Ecova | Generalized Test Protocol for Calculating the Energy Efficiency of Internal AC-DC and DC-AC Power Supplies Revision 6.7

Operating condition class | | The manufacturer has to declare the product operating condition class: A1, A2, A3 or A4. The unit under test is placed at a temperature corresponding to the highest allowable temperature for the specific operating condition class (A1, A2, A3 or A4), which the model is declared to be compliant with. The unit shall be tested with SERT (Server Efficiency Rating Tool) and run test cycle(s) for a duration of 16 hours. The unit shall be considered to comply with the declared operating condition, if SERT reports valid results (i.e. if the unit under test is in its operational state for the whole duration of the 16 hours test). | The unit under test shall be placed in a temperature chamber which is then elevated in temperature to the highest allowable temperature for the specific operating condition class (A1, A2, A3 or A4) at a maximum rate of change of 0.5 °C per minute. The unit under test shall be left in an idle state for 1 hour to attain a state of temperature stability prior to the start of testing.

Firmware availability | | Not available |

Secure data deletion | NIST | Guidelines for Media Sanitization, NIST Special Publication 800-88 - Revision 1 |

Ability of the server to be disassembled | | Not available |

Critical raw material (CRM) content | | EN 45558:2019 |

Parameter | Source | Reference Test Method / Title | Notes

Power Supply Efficiency | EPRI and Ecova | Generalized Test Protocol for Calculating the Energy Efficiency of Internal AC-DC and DC -DC Power Supplies Revision 6.7 | Testing shall be conducted at an appropriate EU voltage and frequency (e.g. 230v, 50Hz).

Power Supply Power Factor | EPRI and Ecova | Generalized Test Protocol for Calculating the Energy Efficiency of Internal AC-DC and DC -DC Power Supplies Revision 6.7

Operating condition class | The Green Grid | ‘Operating condition class of data storage products’ | The manufacturer, importer or authorised representative has to declare the product operating condition class: A1, A2, A3 or A4. The unit under test is placed at a temperature corresponding to the highest allowable temperature for the specific operating condition class (A1, A2, A3 or A4), which the model is declared to be compliant with.

Firmware availability | | Not available |

Secure data deletion | NIST | Guidelines for Media Sanitization, NIST Special Publication 800-88 - Revision 1 |

Ability of the data storage product to be disassembled | | Not available | .

Critical raw material (CRM) content | | EN 45558:2019 |