ANNEX VI, Regulation (EU) 2018/989

In forcesince 18 May 2018

Annex VI to Delegated Regulation (EU) 2017/654 is amended as follows:

(1)

point 1 is replaced by the following:

This Annex describes the method of determining emissions of gaseous and particulate pollutants from the engine to be tested and the specifications related to the measurement equipment. As from section 6, the numbering of this Annex is consistent with the numbering of the Global technical regulation No 11 [Global technical regulation No 11 on Engine Emissions from agricultural and forestry tractors and from non-road mobile machinery under the Global Registry created on 18 November 2004, pursuant to Article 6 of the Agreement concerning the establishing of global technical regulations for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles.] (GTR No 11) and UNECE Regulation No 96.04 series of amendments [Regulation No 96 of the Economic Commission for Europe of the United Nations (UN/ECE) — Uniform provisions concerning the approval of compression ignition (C.I.) engines to be installed in agricultural and forestry tractors and in non-road mobile machinery with regard to the emissions of pollutants by the engine.’;], Annex 4B. However, some points of the GTR No 11 are not needed in this Annex, or are modified in accordance with the technical progress.

(2)

in point 5.1, the second, third and fourth paragraphs are replaced by the following:

‘The measured values of gaseous and particulate pollutants and of CO2 exhausted by the engine refer to the brake-specific emissions in grams per kilowatt-hour (g/kWh), or number per kilowatt-hour (#/kWh) for PN.

The gaseous and particulate pollutants that shall be measured are those for which limit values are applicable to the engine sub-category being tested as set out in Annex II to Regulation (EU) 2016/1628. The results, inclusive of:

(a)

the crankcase emissions determined in accordance with section 6.10, if relevant,

(b)

the adjustment factors for infrequent regeneration of the after-treatment system determined in accordance with section 6.6, if relevant, and

(c)

as the final step of the calculation, the deterioration factor determined in accordance with Annex III,

shall not exceed the applicable limit values.

The CO2 shall be measured and reported for all engine sub-categories as required by Article 43(4) of Regulation (EU) 2016/1628.’;

(3)

point 5.2.5.1.1 is replaced by the following:

In order to calculate the MTS the transient mapping procedure shall be performed in accordance with point 7.4. The MTS is then determined from the mapped values of engine speed versus power. MTS shall be calculated by means of one of the following options:

(a)

Calculation based upon low speed and high speed values

MTS = nlo + 0,95 · (nhi – nlo) | (6-1)

where:

nhiis the high speed as defined in Article 1(12),

nlois the low speed as defined in Article 1(13).

(b)

Calculation based upon the longest vector method

MTS = ni | (6-2)

where:

niis the average of the lowest and highest speeds at which (n2normi + P2normi) is equal to 98 % of the maximum value of (n2normi + P2normi)

If there is only one speed at which the value of (n2normi + P2normi) is equal to 98 % of the maximum value of (n2normi + P2normi):

MTS = ni | (6-3)

where:

niis the speed at which the maximum value of (n2normi + P2normi) occurs.

where:

nis the engine speed

iis an indexing variable that represents one recorded value of an engine map

nnormiis an engine speed normalized by dividing it by nPmax

Pnormiis an engine power normalized by dividing it by Pmax

nPmaxis the average of the lowest and highest speeds at which power is equal to 98 % of Pmax.

Linear interpolation shall be used between the mapped values to determine:

(i)

the speeds where power is equal to 98 % of Pmax. If there is only one speed at which power is equal to 98 % of Pmax, nPmax shall be the speed at which Pmax occurs;

(ii)

the speeds where (n2normi + P2normi) is equal to 98 % of the maximum value of (n2normi + P2normi).’;

(4)

point 5.2.5.2 is amended as follows:

(a)

the first paragraph is replaced by the following:

‘The rated speed is defined in Article 3(29) of Regulation (EU) 2016/1628. Rated speed for variable-speed engines subject to an emission test other than those tested on a constant-speed NRSC defined in Article 1(31) of this Regulation shall be determined from the applicable mapping procedure set out in point 7.6 of this Annex. Rated speed for variable-speed engines tested on a constant-speed NRSC shall be declared by the manufacturer according to the characteristics of the engine. Rated speed for constant-speed engines shall be declared by the manufacturer according to the characteristics of the governor. Where an engine type equipped with alternative speeds as permitted by Article 3(21) of Regulation (EU) 2016/1628 is subject to an emission test, each alternative speed shall be declared and tested.’;

(b)

the third paragraph is replaced by the following:

‘For engines of category NRSh the 100 % test speed shall be within ± 350 rpm of the rated speed declared by the manufacturer.’;

(5)

point 5.2.5.3 is amended as follows:

(a)

the introductory wording of the first paragraph is replaced by the following:

‘Where required, the maximum torque speed determined from the maximum torque curve established by the applicable engine mapping procedure in point 7.6.1 or 7.6.2 shall be one of the following:’;

(b)

in the last paragraph, the words ‘engines of category NRS or NRSh’ are replaced by the words ‘engines of category NRS’;

(6)

in point 6.2, the first paragraph is replaced by the following:

‘A charge-air cooling system with a total intake-air capacity that represents production engines' in-use installation shall be used. Any laboratory charge-air cooling system shall be designed to minimize accumulation of condensate. Any accumulated condensate shall be drained and all drains shall be completely closed before emission testing. The drains shall be kept closed during the emission test. Coolant conditions shall be maintained as follows:

(a)

a coolant temperature of at least 293 K (20 °C) shall be maintained at the inlet to the charge-air cooler throughout testing;

(b)

at the rated speed and full load, the coolant flow rate shall be set to achieve an air temperature within ± 5 K (± 5 °C) of the value designed by the manufacturer after the charge-air cooler's outlet. The air- outlet temperature shall be measured at the location specified by the manufacturer. This coolant flow rate set point shall be used throughout testing;

(c)

if the engine manufacturer specifies pressure-drop limits across the charge-air cooling system, it shall be ensured that the pressure drop across the charge-air cooling system at engine conditions specified by the manufacturer is within the manufacturer's specified limit(s). The pressure drop shall be measured at the manufacturer's specified locations;’;

(7)

point 6.3.4 is replaced by the following:

Where applicable as per point 6.3.2 and 6.3.3, the values of auxiliary power and the measurement/calculation method for determining auxiliary power shall be submitted by the engine manufacturer for the whole operating area of the applicable test cycles, and approved by the approval authority.’;

(8)

point 6.6.2.3 is amended as follows:

(a)

the last sentence of the first paragraph is replaced by the following:

‘The exact procedure to determine this frequency shall be agreed by the approval authority based upon good engineering judgement.’;

(b)

the title of Figure 6.1 is replaced by the following:

(c)

equation (6-9) and the legend thereof are replaced by the following:

‘

e

w

n

e

nr

e

r

n nr

(6-9)

Where:

nis the number of tests in which regeneration does not occur,

nris the number of tests in which regeneration occurs (minimum one test),

e

is the average specific emission from a test in which the regeneration does not occur [g/kWh or #/kWh]

e

ris the average specific emission from a test in which the regeneration occurs [g/kWh or #/kWh]’;

(d)

equations (6-10) and (6-11) are replaced by the following:

‘kru,m

e

w

e

(upward adjustment factor) | (6-10)

krd,m

e

w

e

r

(downward adjustment factor) | (6-11)’;

(a)

equations (6-12) and (6-13) are replaced by the following:

‘kru,a

ew

e

(upward adjustment factor) | (6-12)

krd,a

ew

er

(downward adjustment factor) | (6-13)’;

(9)

in point 6.6.2.4, in the third paragraph, point (b) is replaced by the following:

‘(b) Upon request by the manufacturer, the approval authority may account for regeneration events differently than pursuant to point (a). However, this option only applies to events that occur extremely infrequently, and which cannot be practically addressed using the adjustment factors described in point 6.6.2.3.’;

(10)

point 7.3.1.1 is amended as follows:

(a)

the heading is replaced by the following:

(b)

the following paragraph is added:

‘Engines fitted with an after-treatment system may be operated prior to cycle-specific preconditioning set out in points 7.3.1.1.1 to 7.3.1.1.4, so that the after-treatment system is regenerated and, where applicable, the soot load in the particulate after-treatment system is re-established.’;

(11)

point 7.3.1.1.5 is deleted;

(12)

points 7.3.1.2 to 7.3.1.5 are replaced by the following:

A natural or forced cool-down procedure may be applied. For forced cool-down, good engineering judgment shall be used to set up systems to send cooling air across the engine, to send cool oil through the engine lubrication system, to remove heat from the coolant through the engine cooling system, and to remove heat from an exhaust after-treatment system. In the case of a forced after-treatment cool down, cooling air shall not be applied until the exhaust after-treatment system has cooled below its catalytic activation temperature. Any cooling procedure that results in unrepresentative emissions is not permitted.

If there is any presumption of an essential HC contamination of the exhaust gas measuring system, the contamination with HC may be checked with zero gas and the hang-up may then be corrected. If the amount of contamination of the measuring system and the background HC system has to be checked, it shall be conducted within 8 hours of starting each test-cycle. The values shall be recorded for later correction. Before this check, the leak check has to be performed and the FID analyzer has to be calibrated.

The following steps shall be taken before emission sampling begins:

(a)

Leak checks shall be performed within 8 hours prior to emission sampling in accordance with point 8.1.8.7;

(b)

For batch sampling, clean storage media shall be connected, such as evacuated bags or tare-weighed filters;

(c)

All measurement instruments shall be started in accordance with the instrument manufacturer's instructions and good engineering judgment;

(d)

Dilution systems, sample pumps, cooling fans, and the data-collection system shall be started;

(e)

The sample flow rates shall be adjusted to desired levels, using bypass flow, if desired;

(f)

Heat exchangers in the sampling system shall be pre-heated or pre-cooled to within their operating temperature ranges for a test;

(g)

Heated or cooled components such as sample lines, filters, chillers, and pumps shall be allowed to stabilize at their operating temperatures;

(h)

Exhaust gas dilution system flow shall be switched on at least 10 minutes before a test sequence;

(i)

Calibration of gas analyzers and zeroing of continuous analyzers shall be carried out in accordance with the procedure of point 7.3.1.5;

(j)

Any electronic integrating devices shall be zeroed or re-zeroed, before the start of any test interval.

Appropriate gas analyzer ranges shall be selected. Emission analyzers with automatic or manual range switching are allowed. During a test using transient (NRTC or LSI-NRTC) test cycles or RMC and during a sampling period of a gaseous emission at the end of each mode for discrete-mode NRSC testing, the range of the emission analyzers shall not be switched. Also the gains of an analyzer's analogue operational amplifier(s) shall not be switched during a test cycle.

All continuous analyzers shall be zeroed and spanned using internationally-traceable gases that meet the specifications of point 9.5.1. FID analyzers shall be spanned on a carbon number basis of one (C1).’;

(13)

the following point 7.3.1.6 is inserted:

The procedures for PM filter preconditioning and tare weighing shall be performed in accordance with point 8.2.3.’;

(14)

point 7.4 is replaced by the following:

The EU type-approval test shall be conducted using the appropriate NRSC and, where applicable, NRTC or LSI-NRTC, specified in Article 18 of Regulation (EU) 2016/1628 and Annex IV thereto. The technical specifications and characteristics of the NRSC, NRTC and LSI-NRTC are laid down in Annex XVII of this Regulation and the method for determination of the torque, power and speed settings for these test cycles set out in section 5.2.’;

(15)

point 7.5 is amended as follows:

(a)

in the first paragraph, point (h) is replaced by the following:

‘(h) PM filter(s) shall be pre-conditioned, weighed (empty weight), loaded, re-conditioned, again weighed (loaded weight) and then samples shall be evaluated in accordance with the pre-test (point 7.3.1.6) and post-test (point 7.3.2.2) procedures;’;

(b)

Figure 6.4 is replaced by the following:

’

(16)

in point 7.5.1.2, points (a) and (b) are replaced by the following:

‘(a) If the engine stalls anywhere during the cold start run of the NRTC, the entire test shall be voided;

(b)

If the engine stalls anywhere during the hot-start run of the NRTC, only this run shall be voided. The engine shall be soaked in accordance with point 7.8.3, and the hot-start run repeated. In this case, the cold-start run does not need to be repeated;’;

(17)

point 7.8.1.2 is amended as follows:

(a)

point (b) is replaced by the following:

‘(b) Each mode has a mode length of at least 10 minutes. In each mode the engine shall be stabilised for at least 5 minutes. Gaseous emissions, and, where applicable, PN, shall be sampled for 1 to 3 minutes at the end of each mode and PM emissions shall be sampled in accordance with point (c).

Notwithstanding the previous paragraph, when either testing spark ignition engines using cycles G1, G2 or G3 or when conducting measurements in accordance with Annex V of this Regulation each mode has a mode length of at least 3 minutes. In this case gaseous emissions, and, where applicable, PN, shall be sampled for at least the last 2 minutes of each mode and PM emissions shall be sampled in accordance with point (c). The mode length and sampling time may be extended to improve accuracy.

The mode length shall be recorded and reported.’;

(b)

in point (c), the first paragraph is replaced by the following:

‘For PM emissions, the PM sampling may be done either with the single filter method or with the multiple filter method. Since the results of the methods may differ slightly, the method used shall be declared with the results.’;

(18)

in point 7.8.2.4, the last sentence of the first paragraph is replaced by the following:

‘When conducting testing of engines of reference power greater than 560 kW the regression line tolerances of Table 6.2 and the point deletion of Table 6.3 may be used.’;

(19)

in point 7.8.3.5, Table 6.3 is replaced by the following:

Where:

nrefis the reference speed (see section 7.7.2.),

nidleis the idle speed,

nactis the actual (measured) speed,

Trefis the reference torque (see section 7.7.2.),

Tactis the actual (measured) torque,

Tmaxmappedtorqueis the highest value of torque on the full-load torque curve mapped in accordance with section 7.6.’;

Event | Conditions (n = engine speed, T = torque) | Permitted point deletions

Minimum operator demand (idle point) |

nref = nidle

and

Tref = 0 %

and

Tact > (Tref – 0,02 Tmaxmappedtorque)

and

Tact < (Tref + 0,02 Tmaxmappedtorque)

speed and power

Minimum operator demand |

nact ≤ 1,02 nref and Tact > Tref

or

nact > nref and Tact ≤ Tref'

or

nact > 1,02 nref and Tref < Tact ≤ (Tref + 0,02 Tmaxmappedtorque)

power and either torque or speed

Maximum operator demand |

nact < nref and Tact ≥ Tref

or

nact ≥ 0,98 nref and Tact < Tref

or

nact < 0,98 nref and Tref > Tact ≥ (Tref – 0,02 Tmaxmappedtorque)

power and either torque or speed

(20)

in point 8.1.2, Table 6.4 is amended as follows:

(a)

the row referring to point 8.1.11.4 is replaced by the following:

‘8.1.11.4.: Sample dryer NO2 penetration (chiller) | Upon initial installation and after major maintenance.’;

(b)

the row referring to point 8.1.12.1 is replaced by the following:

‘8.1.12.: Sample dryer verification | For thermal chillers: upon installation and after major maintenance. For osmotic membranes: upon installation, within 35 days of testing and after major maintenance.’;

(21)

point 8.1.7 is replaced by the following:

Internal quality procedures traceable to recognised national or international standards shall be applied. Otherwise the following procedures apply.’;

(22)

in point 8.1.8.4.1(f), the first paragraph is replaced by the following:

‘CFV or SSV may alternatively be removed from its permanent position for calibration as long as the following requirements are met when installed in the CVS:’;

(23)

in point 8.1.8.5.1(a), point (iv) is replaced by the following:

‘(iv) The hydrocarbon contamination verification in the sample system shall be performed as described in point 7.3.1.3;’;

(24)

in point 8.1.8.5.4, the first and second sentence below the heading are replaced by the following:

‘Vacuum side leak check verification of the HC sampling system may be performed in accordance with point (g). If this procedure is used, the HC contamination procedure set out in point 7.3.1.3 may be used.’;

(25)

point 8.1.8.5.8 is deleted;

(26)

point 8.1.9.1.2 is replaced by the following:

H2O can interfere with an NDIR analyzer's response to CO2. If the NDIR analyzer uses compensation algorithms that utilize measurements of other gases to meet this interference verification, these other measurements shall be conducted simultaneously to test the compensation algorithms during the analyzer interference verification.’;

(27)

in point 8.1.9.1.4, point (b) is replaced by the following:

‘(b) A humidified test gas shall be created by bubbling zero air that meets the specifications set out in point 9.5.1 through distilled water in a sealed vessel. If the sample is not passed through a dryer, control the vessel temperature to generate an H2O content in the test gas at least as high as the maximum expected during testing. If the sample is passed through a dryer during testing, control the vessel temperature to generate an H2O content in the test gas at least as high as the maximum expected at the outlet of the dryer, in accordance with point 9.3.2.3.1.1;’;

(28)

point 8.1.9.2.4(b) is replaced by the following:

‘(b) A humidified CO2 test gas shall be created by bubbling a CO2 span gas through distilled water in a sealed vessel. If the sample is not passed through a dryer, the vessel temperature shall be controlled to generate an H2O content in the test gas at least as high as the maximum expected during testing. If the sample is passed through a dryer during testing, the vessel temperature shall be controlled to generate an H2O content in the test gas at least as high as the maximum expected at the outlet of the dryer, in accordance with point 9.3.2.3.1.1. A CO2 span gas concentration shall be used at least as high as the maximum expected during testing;’;

(29)

point 8.1.10.1.3 is amended as follows:

(a)

in point (b), the last sentence is replaced by the following:

‘With the FID fuel and airflow rates set at the manufacturer's recommendations, a span gas shall be introduced to the analyzer;’;

(b)

point (c) is amended as follows:

(i)

point (i) is replaced by the following:

‘(i) The response at a given FID fuel flow shall be determined from the difference between the span gas response and the zero gas response;’;

(ii)

in point (ii), the last sentence is replaced by the following:

‘The span and zero response at these FID fuel flows shall be recorded;’;

(30)

in point 8.1.10.2.4(a), the second sentence is deleted;

(31)

point 8.1.11.1.5 is amended as follows:

(a)

point (e) is replaced by the following:

‘(e) The NO span gas shall be humidified by bubbling it through distilled water in a sealed vessel. If the humidified NO span gas sample does not pass through a sample dryer for this verification test, the vessel temperature shall be controlled to generate an H2O content in the span gas approximately equal to the maximum mole fraction of H2O expected during emission testing. If the humidified NO span gas sample does not pass through a sample dryer, the quench verification calculations in point 8.1.11.2.3 scale the measured H2O quench to the highest mole fraction of H2O expected during emission testing. If the humidified NO span gas sample passes through a dryer for this verification test, the vessel temperature shall be controlled to generate an H2O content in the span gas at least as high as the maximum expected at the outlet of the dryer in accordance with point 9.3.2.3.1.1. In this case, the quench verification calculations set out in point 8.1.11.2.3 do not scale the measured H2O quench;’;

(b)

the last sentence of point (f) is replaced by the following: ‘Note that the sample dryer shall meet the sample dryer verification check in point 8.1.12;’;

(32)

in point 8.1.11.3.4(g), the introductory wording is replaced by the following:

‘This difference shall be multiplied by the ratio of the expected mean HC concentration to the HC concentration measured during the verification. The analyzer meets the interference verification of this point if this result is within ± 2 % of the NOx concentration expected at the emission limit value, as set out in equation (6-25):’;

(33)

in point 8.1.11.4.2, the words ‘cooling bath’ are replaced by the words ‘sample dryer’.

(34)

point 8.1.12 is replaced by the following:

If a humidity sensor for continuous monitoring of dew point at the sample dryer outlet is used this check does not apply, as long as it is ensured that the dryer outlet humidity is below the minimum values used for quench, interference, and compensation checks.

If a sample dryer is used as allowed in point 9.3.2.3.1 to remove water from the sample gas, the performance shall be verified upon installation, after major maintenance, for thermal chillers. For osmotic membrane dryers, the performance shall be verified upon installation, after major maintenance, and within 35 days of testing.

This article is long: the rest is at the official publication.