ANNEX II, Regulation (EU) 2016/1628

In forcesince 14 Sep 2016

[0,60 for hand-startable, air-cooled direct injection engines.]

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A

kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |

Stage V |

NRE-v-1

NRE-c-1

0 < P < 8 | CI | 8,00 | (HC + NOx ≤ 7,50) | 0,40 | — | 1,10

Stage V |

NRE-v-2

NRE-c-2

8 ≤ P < 19 | CI | 6,60 | (HC + NOx ≤ 7,50) | 0,40 | — | 1,10

Stage V |

NRE-v-3

NRE-c-3

19 ≤ P < 37 | CI | 5,00 | (HC + NOx ≤ 4,70) | 0,015 | 1 × 1012 | 1,10

Stage V |

NRE-v-4

NRE-c-4

37 ≤ P < 56 | CI | 5,00 | (HC + NOx ≤ 4,70) | 0,015 | 1 × 1012 | 1,10

Stage V |

NRE-v-5

NRE-c-5

56 ≤ P < 130 | all | 5,00 | 0,19 | 0,40 | 0,015 | 1 × 1012 | 1,10

Stage V |

NRE-v-6

NRE-c-6

130 ≤ P ≤ 560 | all | 3,50 | 0,19 | 0,40 | 0,015 | 1 × 1012 | 1,10

Stage V |

NRE-v-7

NRE-c-7

P > 560 | all | 3,50 | 0,19 | 3,50 | 0,045 | — | 6,00

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A

kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |

Stage V |

NRG-v-1

NRG-c-1

P > 560 | all | 3,50 | 0,19 | 0,67 | 0,035 | — | 6,00

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC + NOx

kW | | g/kWh | g/kWh

Stage V | NRSh-v-1a | 0 < P < 19 | SI | 805 | 50

Stage V | NRSh-v-1b | 603 | 72

[Optionally, as an alternative, any combination of values satisfying the equation (HC + NOX) × CO0,784 ≤ 8,57 as well as the following conditions: CO ≤ 20,6 g/kWh and (HC + NOX) ≤ 2,7 g/kWh]

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC + NOx

kW | | g/kWh | g/kWh

Stage V |

NRS-vr-1a

NRS-vi-1a

0 < P < 19 | SI | 610 | 10

Stage V |

NRS-vr-1b

NRS-vi-1b

610 | 8

Stage V | NRS-v-2a | 19 ≤ P ≤ 30 | 610 | 8

Stage V |

NRS-v-2b

NRS-v-3

19 ≤ P < 56 | 4,40 | 2,70

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A

kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |

Stage V |

IWP-v-1

IWP-c-1

19 ≤ P < 75 | all | 5,00 | (HC + NOx ≤ 4,70) | 0,30 | — | 6,00

Stage V |

IWP-v-2

IWP-c-2

75 ≤ P < 130 | all | 5,00 | (HC + NOx ≤ 5,40) | 0,14 | — | 6,00

Stage V |

IWP-v-3

IWP-c-3

130 ≤ P < 300 | all | 3,50 | 1,00 | 2,10 | 0,10 | — | 6,00

Stage V |

IWP-v-4

IWP-c-4

P ≥ 300 | all | 3,50 | 0,19 | 1,80 | 0,015 | 1 × 1012 | 6,00

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A

kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |

Stage V |

IWA-v-1

IWA-c-1

19 ≤ P < 75 | all | 5,00 | (HC + NOx ≤ 4,70) | 0,30 | — | 6,00

Stage V |

IWA-v-2

IWA-c-2

75 ≤ P < 130 | all | 5,00 | (HC + NOx ≤ 5,40) | 0,14 | — | 6,00

Stage V |

IWA-v-3

IWA-c-3

130 ≤ P < 300 | all | 3,50 | 1,00 | 2,10 | 0,10 | — | 6,00

Stage V |

IWA-v-4

IWA-c-4

P ≥ 300 | all | 3,50 | 0,19 | 1,80 | 0,015 | 1 × 1012 | 6,00

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A

kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |

Stage V |

RLL-c-1

RLL-v-1

P > 0 | all | 3,50 | (HC + NOx ≤ 4,00) | 0,025 | — | 6,00

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A

kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |

Stage V |

RLR-c-1

RLR-v-1

P > 0 | all | 3,50 | 0,19 | 2,00 | 0,015 | 1 × 1012 | 6,00

Emission stage | Engine sub-category | Power range | Ignition type | CO | NOx | HC

kW | | g/kWh | g/kWh | g/kWh

Stage V | SMB-v-1 | P > 0 | SI | 275 | — | 75

Emission stage | Engine sub-category | Power range | Ignition type | CO | HC + NOx

kW | | g/kWh | g/kWh

Stage V | ATS-v-1 | P > 0 | SI | 400 | 8

1.

For the sub-categories where an A-factor is defined, the HC limit for fully and partially gaseous-fuelled engines indicated in Tables II-1 to II-10 is replaced by a limit calculated using the following formula:

HC = 0,19 + (1,5 × A × GER)

where GER is the average gas energy ratio over the appropriate test cycle. Where both a steady-state and transient test cycle apply, the GER shall be determined from the hot-start transient test cycle. Where more than one steady-state test cycle applies, the average GER shall be determined for each cycle individually.

If the calculated limit for HC exceeds the value of 0,19 + A, the limit for HC shall be set to 0,19 + A.

2.

For sub-categories with a combined HC and NOx limit, the combined limit value for HC and NOx shall be reduced by 0,19 g/kWh and apply for NOx only.

3.

For non-gaseous-fuelled engines, the formula does not apply.