[0,60 for hand-startable, air-cooled direct injection engines.]
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A
kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |
Stage V |
NRE-v-1
NRE-c-1
0 < P < 8 | CI | 8,00 | (HC + NOx ≤ 7,50) | 0,40 | — | 1,10
Stage V |
NRE-v-2
NRE-c-2
8 ≤ P < 19 | CI | 6,60 | (HC + NOx ≤ 7,50) | 0,40 | — | 1,10
Stage V |
NRE-v-3
NRE-c-3
19 ≤ P < 37 | CI | 5,00 | (HC + NOx ≤ 4,70) | 0,015 | 1 × 1012 | 1,10
Stage V |
NRE-v-4
NRE-c-4
37 ≤ P < 56 | CI | 5,00 | (HC + NOx ≤ 4,70) | 0,015 | 1 × 1012 | 1,10
Stage V |
NRE-v-5
NRE-c-5
56 ≤ P < 130 | all | 5,00 | 0,19 | 0,40 | 0,015 | 1 × 1012 | 1,10
Stage V |
NRE-v-6
NRE-c-6
130 ≤ P ≤ 560 | all | 3,50 | 0,19 | 0,40 | 0,015 | 1 × 1012 | 1,10
Stage V |
NRE-v-7
NRE-c-7
P > 560 | all | 3,50 | 0,19 | 3,50 | 0,045 | — | 6,00
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A
kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |
Stage V |
NRG-v-1
NRG-c-1
P > 560 | all | 3,50 | 0,19 | 0,67 | 0,035 | — | 6,00
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC + NOx
kW | | g/kWh | g/kWh
Stage V | NRSh-v-1a | 0 < P < 19 | SI | 805 | 50
Stage V | NRSh-v-1b | 603 | 72
[Optionally, as an alternative, any combination of values satisfying the equation (HC + NOX) × CO0,784 ≤ 8,57 as well as the following conditions: CO ≤ 20,6 g/kWh and (HC + NOX) ≤ 2,7 g/kWh]
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC + NOx
kW | | g/kWh | g/kWh
Stage V |
NRS-vr-1a
NRS-vi-1a
0 < P < 19 | SI | 610 | 10
Stage V |
NRS-vr-1b
NRS-vi-1b
610 | 8
Stage V | NRS-v-2a | 19 ≤ P ≤ 30 | 610 | 8
Stage V |
NRS-v-2b
NRS-v-3
19 ≤ P < 56 | 4,40 | 2,70
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A
kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |
Stage V |
IWP-v-1
IWP-c-1
19 ≤ P < 75 | all | 5,00 | (HC + NOx ≤ 4,70) | 0,30 | — | 6,00
Stage V |
IWP-v-2
IWP-c-2
75 ≤ P < 130 | all | 5,00 | (HC + NOx ≤ 5,40) | 0,14 | — | 6,00
Stage V |
IWP-v-3
IWP-c-3
130 ≤ P < 300 | all | 3,50 | 1,00 | 2,10 | 0,10 | — | 6,00
Stage V |
IWP-v-4
IWP-c-4
P ≥ 300 | all | 3,50 | 0,19 | 1,80 | 0,015 | 1 × 1012 | 6,00
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A
kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |
Stage V |
IWA-v-1
IWA-c-1
19 ≤ P < 75 | all | 5,00 | (HC + NOx ≤ 4,70) | 0,30 | — | 6,00
Stage V |
IWA-v-2
IWA-c-2
75 ≤ P < 130 | all | 5,00 | (HC + NOx ≤ 5,40) | 0,14 | — | 6,00
Stage V |
IWA-v-3
IWA-c-3
130 ≤ P < 300 | all | 3,50 | 1,00 | 2,10 | 0,10 | — | 6,00
Stage V |
IWA-v-4
IWA-c-4
P ≥ 300 | all | 3,50 | 0,19 | 1,80 | 0,015 | 1 × 1012 | 6,00
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A
kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |
Stage V |
RLL-c-1
RLL-v-1
P > 0 | all | 3,50 | (HC + NOx ≤ 4,00) | 0,025 | — | 6,00
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC | NOx | PM mass | PN | A
kW | | g/kWh | g/kWh | g/kWh | g/kWh | #/kWh |
Stage V |
RLR-c-1
RLR-v-1
P > 0 | all | 3,50 | 0,19 | 2,00 | 0,015 | 1 × 1012 | 6,00
Emission stage | Engine sub-category | Power range | Ignition type | CO | NOx | HC
kW | | g/kWh | g/kWh | g/kWh
Stage V | SMB-v-1 | P > 0 | SI | 275 | — | 75
Emission stage | Engine sub-category | Power range | Ignition type | CO | HC + NOx
kW | | g/kWh | g/kWh
Stage V | ATS-v-1 | P > 0 | SI | 400 | 8
For the sub-categories where an A-factor is defined, the HC limit for fully and partially gaseous-fuelled engines indicated in Tables II-1 to II-10 is replaced by a limit calculated using the following formula:
HC = 0,19 + (1,5 × A × GER)
where GER is the average gas energy ratio over the appropriate test cycle. Where both a steady-state and transient test cycle apply, the GER shall be determined from the hot-start transient test cycle. Where more than one steady-state test cycle applies, the average GER shall be determined for each cycle individually.
If the calculated limit for HC exceeds the value of 0,19 + A, the limit for HC shall be set to 0,19 + A.
For sub-categories with a combined HC and NOx limit, the combined limit value for HC and NOx shall be reduced by 0,19 g/kWh and apply for NOx only.
For non-gaseous-fuelled engines, the formula does not apply.