Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
NRE | CI | variable | 0 < P < 8 | NRE-v-1 | Maximum net power
CI | 8 ≤ P < 19 | NRE-v-2
CI | 19 ≤ P < 37 | NRE-v-3
CI | 37 ≤ P < 56 | NRE-v-4
all | 56 ≤ P < 130 | NRE-v-5
130 ≤ P ≤ 560 | NRE-v-6
P > 560 | NRE-v-7
CI | constant | 0 < P < 8 | NRE-c-1 | Rated net power
CI | 8 ≤ P < 19 | NRE-c-2
CI | 19 ≤ P < 37 | NRE-c-3
CI | 37 ≤ P < 56 | NRE-c-4
all | 56 ≤ P < 130 | NRE-c-5
130 ≤ P ≤ 560 | NRE-c-6
P > 560 | NRE-c-7
Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
NRG | all | variable | P > 560 | NRG-v-1 | Maximum net power
constant | P > 560 | NRG-c-1 | Rated net power
Category | Ignition type | Speed operation | Power range (kW) | Swept volume (cm3) | Sub-category | Reference power
NRSh | SI | variable or constant | 0 < P < 19 | SV < 50 | NRSh-v-1a | Maximum net power
SV ≥ 50 | NRSh-v-1b
Category | Ignition type | Speed operation | Power range (kW) | Swept volume (cm3) | Sub-category | Reference power
NRS | SI | variable ≥ 3600 rpm; or constant | 0 < P < 19 | 80 ≤ SV < 225 | NRS-vr-1a | Maximum net power
SV ≥ 225 | NRS-vr-1b
variable < 3600 rpm | 80 ≤ SV < 225 | NRS-vi-1a
SV ≥ 225 | NRS-vi-1b
variable or constant | 19 ≤ P < 30 | SV ≤ 1000 | NRS-v-2a | Maximum net power
SV > 1000 | NRS-v-2b
30 ≤ P < 56 | any | NRS-v-3 | Maximum net power
For engines < 19 kW with SV < 80 cm3 in machinery other than hand-held machinery, engines of the category NRSh shall be used.
Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
IWP | all | variable | 19 ≤ P < 75 | IWP-v-1 | Maximum net power
75 ≤ P < 130 | IWP-v-2
130 ≤ P < 300 | IWP-v-3
P ≥ 300 | IWP-v-4
constant | 19 ≤ P < 75 | IWP-c-1 | Rated net power
75 ≤ P < 130 | IWP-c-2
130 ≤ P < 300 | IWP-c-3
P ≥ 300 | IWP-c-4
Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
IWA | all | variable | 19 ≤ P < 75 | IWA-v-1 | Maximum net power
75 ≤ P < 130 | IWA-v-2
130 ≤ P < 300 | IWA-v-3
P ≥ 300 | IWA-v-4
constant | 19 ≤ P < 75 | IWA-c-1 | Rated net power
75 ≤ P < 130 | IWA-c-2
130 ≤ P < 300 | IWA-c-3
P ≥ 300 | IWA-c-4
Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
RLL | all | variable | P > 0 | RLL-v-1 | Maximum net power
constant | P > 0 | RLL-c-1 | Rated net power
Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
RLR | all | variable | P > 0 | RLR-v-1 | Maximum net power
constant | P > 0 | RLR-c-1 | Rated net power
Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
SMB | SI | variable or constant | P > 0 | SMB-v-1 | Maximum net power
Category | Ignition type | Speed operation | Power range (kW) | Sub-category | Reference power
ATS | SI | variable or constant | P > 0 | ATS-v-1 | Maximum net power