ANNEX IV, Commission Regulation (EU) No 136/2014 of 11 February 2014 amending Directive 2007/46/EC…

In forcesince 11 Feb 2014

Regulation (EU) No 582/2011 is amended as follows:

(1)

Annex VIII is amended as follows:

(a)

In Appendix 1, point 2.1.2.(2) is replaced by the following:

‘(2) hydrogen-carbon-oxygen ratio: fixed values shall be used which are:

C1H1,93O0,033 for petrol (E10),

C1H1,86O0,007 for diesel (B7),

C1H2,525 for LPG (liquefied petroleum gas),

CH4 for NG (natural gas) and biomethane,

C1H2,74O0,385 for ethanol (E85),

C1H2,92O0,046 for ethanol for dedicated C.I. engines (ED95).’

(b)

In Appendix 1, point 2.1.3.(a) is replaced by the following:

‘(a) for vehicles with a positive ignition engine fuelled with petrol (E10):

FC0,120D0,830 HC0,429 CO0,273 CO2’

(c)

In Appendix 1, point 2.1.3.(e) is replaced by the following:

‘(e) for vehicles with a compression-ignition engine fuelled with diesel (B7):

FC0,116D0,859 HC0,429 CO0,273 CO2’

(2)

Annex IX is amended as follows:

(a)

In the section ‘Technical data on fuels for testing compression-ignition engines’, the table with the title ‘Type Diesel (B7)’ is replaced by the following table:

[The values quoted in the specifications are “true values”. In establishment of their limit values the terms of ISO 4259 Petroleum products – Determination and application of precision data in relation to methods of test have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum difference is 4R (R = reproducibility). Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels shall nevertheless aim at a zero value where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it be necessary to clarify whether a fuel meets the requirements of the specifications, the terms of ISO 4259 shall be applied.] [The range for cetane number is not in accordance with the requirements of a minimum range of 4R. However, in the case of a dispute between fuel supplier and fuel user, the terms of ISO 4259 may be used to resolve such disputes provided replicate measurements, of sufficient number to archive the necessary precision, are made in preference to single determinations.] [Even though oxidation stability is controlled, it is likely that shelf life will be limited. Advice shall be sought from the supplier as to storage conditions and life.] [FAME content to meet the specification of EN 14214.’]

Parameter | Unit | Limits | Test method

Minimum | Maximum

Cetane Index | | 46,0 | | EN ISO 4264

Cetane number | | 52,0 | 56,0 | EN ISO 5165

Density at 15 °C | kg/m3 | 833,0 | 837,0 | EN ISO 12185

Distillation: | | | |

–

50 % point

°C | 245,0 | — | EN ISO 3405

–

95 % point

°C | 345,0 | 360,0 | EN ISO 3405

–

final boiling point

°C | — | 370,0 | EN ISO 3405

Flash point | °C | 55 | — | EN ISO 2719

Cloud point | °C | — | –10 | EN 23015

Viscosity at 40 °C | mm2/s | 2,30 | 3,30 | EN ISO 3104

Polycyclic aromatic hydrocarbons | % m/m | 2,0 | 4,0 | EN 12916

Sulphur content | mg/kg | — | 10,0 |

EN ISO 20846

EN ISO 20884

Copper corrosion 3hrs, 50 °C | | — | Class 1 | EN ISO 2160

Conradson carbon residue (10 % DR) | % m/m | — | 0,20 | EN ISO 10370

Ash content | % m/m | — | 0,010 | EN ISO 6245

Total contamination | mg/kg | — | 24 | EN 12662

Water content | mg/kg | — | 200 | EN ISO 12937

Acid number | mg KOH/g | — | 0,10 | EN ISO 6618

Lubricity (HFRR wear scan diameter at 60 °C) | μm | — | 400 | EN ISO 12156

Oxidation stability at 110 °C | h | 20,0 | | EN 15751

FAME | % v/v | 6,0 | 7,0 | EN 14078

(b)

In the section ‘Technical data on fuels for testing positive-ignition engines’, the table with the title ‘Type Petrol (E10)’ is replaced by the following:

[The values quoted in the specifications are “true values”. In establishment of their limit values the terms of ISO 4259 Petroleum products - Determination and application of precision data in relation to methods of test have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum difference is 4R (R = reproducibility). Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels shall nevertheless aim at a zero value where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it be necessary to clarify whether a fuel meets the requirements of the specifications, the terms of ISO 4259 shall be applied.]

(2)

Equivalent EN/ISO methods will be adopted when issued for properties listed above.

[A correction factor of 0,2 for MON and RON shall be subtracted for the calculation of the final result in accordance with EN 228:2008.] [The fuel may contain oxidation inhibitors and metal deactivators normally used to stabilise refinery gasoline streams, but detergent/dispersive additives and solvent oils shall not be added.] [Ethanol is the only oxygenate that shall be intentionally added to the reference fuel. The ethanol used shall conform to EN 15376.] [The actual sulphur content of the fuel used for the Type 6 test shall be reported.] [There shall be no intentional addition of compounds containing phosphorus, iron, manganese, or lead to this reference fuel.’]

Parameter | Unit | Limits | Test method

Minimum | Maximum

Research octane number, RON | | 95,0 | 98,0 | EN ISO 5164

Motor octane number, MON | | 85,0 | 89,0 | EN ISO 5163

Density at 15 °C | kg/m3 | 743,0 | 756,0 | EN ISO 12185

Vapour pressure (DVPE) | kPa | 56,0 | 60,0 | EN 13016-1

Water content | |

max 0,05 % v/v

Appearance at – 7 °C: clear and bright

EN 12937

Distillation: | | | |

–

evaporated at 70 °C

% v/v | 34,0 | 46,0 | EN ISO 3405

–

evaporated at 100 °C

% v/v | 54,0 | 62,0 | EN ISO 3405

–

evaporated at 150 °C

% v/v | 86,0 | 94,0 | EN ISO 3405

–

final boiling point

°C | 170 | 195 | EN ISO 3405

Residue | % v/v | — | 2,0 | EN ISO 3405

Hydrocarbon analysis: | | | |

–

olefins

% v/v | 6,0 | 13,0 | EN 22854

–

aromatics

% v/v | 25,0 | 32,0 | EN 22854

–

benzene

% v/v | — | 1,00 | EN 22854 EN 238

–

saturates

% v/v | report | EN 22854

Carbon/hydrogen ratio | | report |

Carbon/oxygen ratio | | report |

Induction Period | minutes | 480 | — | EN ISO 7536

Oxygen content | % m/m | 3,3 | 3,7 | EN 22854

Solvent washed gum (Existent gum content) | mg/100 ml | — | 4 | EN ISO 6246

Sulphur content | mg/kg | — | 10 |

EN ISO 20846

EN ISO 20884

Copper corrosion 3hrs, 50 °C | | — | class 1 | EN ISO 2160

Lead content | mg/l | — | 5 | EN 237

Phosphorus content | mg/l | — | 1,3 | ASTM D 3231

Ethanol | % v/v | 9,0 | 10,0 | EN 22854