ANNEX II, Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Direc…

In forcesince 18 Feb 2013

The seasonal space heating energy efficiency class of a heater, with the exception of low-temperature heat pumps and heat pump space heaters for low-temperature application, shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 1.

The seasonal space heating energy efficiency classes of a low-temperature heat pump and a heat pump space heater for low-temperature application shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 2.

The seasonal space heating energy efficiency of a heater shall be calculated in accordance with points 3 and 4 of Annex VII, for heat pump space heaters, heat pump combination heaters and low-temperature heat pumps under average climate conditions.

Seasonal space heating energy efficiency class | Seasonal space heating energy efficiency ηs in %

A+++ | ηs ≥ 150

A++ | 125 ≤ ηs < 150

A+ | 98 ≤ ηs < 125

A | 90 ≤ ηs < 98

B | 82 ≤ ηs < 90

C | 75 ≤ ηs < 82

D | 36 ≤ ηs < 75

E | 34 ≤ ηs < 36

F | 30 ≤ ηs < 34

G | ηs < 30

Seasonal space heating energy efficiency class | Seasonal space heating energy efficiency ηs in %

A+++ | ηs ≥ 175

A++ | 150 ≤ ηs < 175

A+ | 123 ≤ ηs < 150

A | 115 ≤ ηs < 123

B | 107 ≤ ηs < 115

C | 100 ≤ ηs < 107

D | 61 ≤ ηs < 100

E | 59 ≤ ηs < 61

F | 55 ≤ ηs < 59

G | ηs < 55

The water heating energy efficiency class of a combination heater shall be determined on the basis of its water heating energy efficiency as set out in Table 3.

The water heating energy efficiency of a combination heater shall be calculated in accordance with point 5 of Annex VII.

3XS | XXS | XS | S | M | L | XL | XXL

A+++ | ηwh ≥ 62 | ηwh ≥ 62 | ηwh ≥ 69 | ηwh ≥ 90 | ηwh ≥ 163 | ηwh ≥ 188 | ηwh ≥ 200 | ηwh ≥ 213

A++ | 53 ≤ ηwh < 62 | 53 ≤ ηwh < 62 | 61 ≤ ηwh < 69 | 72 ≤ ηwh < 90 | 130 ≤ ηwh < 163 | 150 ≤ ηwh < 188 | 160 ≤ ηwh < 200 | 170 ≤ ηwh < 213

A+ | 44 ≤ ηwh < 53 | 44 ≤ ηwh < 53 | 53 ≤ ηwh < 61 | 55 ≤ ηwh < 72 | 100 ≤ ηwh < 130 | 115 ≤ ηwh < 150 | 123 ≤ ηwh < 160 | 131 ≤ ηwh < 170

A | 35 ≤ ηwh < 44 | 35 ≤ ηwh < 44 | 38 ≤ ηwh < 53 | 38 ≤ ηwh < 55 | 65 ≤ ηwh < 100 | 75 ≤ ηwh < 115 | 80 ≤ ηwh < 123 | 85 ≤ ηwh < 131

B | 32 ≤ ηwh < 35 | 32 ≤ ηwh < 35 | 35 ≤ ηwh < 38 | 35 ≤ ηwh < 38 | 39 ≤ ηwh < 65 | 50 ≤ ηwh < 75 | 55 ≤ ηwh < 80 | 60 ≤ ηwh < 85

C | 29 ≤ ηwh < 32 | 29 ≤ ηwh < 32 | 32 ≤ ηwh < 35 | 32 ≤ ηwh < 35 | 36 ≤ ηwh < 39 | 37 ≤ ηwh < 50 | 38 ≤ ηwh < 55 | 40 ≤ ηwh < 60

D | 26 ≤ ηwh < 29 | 26 ≤ ηwh < 29 | 29 ≤ ηwh < 32 | 29 ≤ ηwh < 32 | 33 ≤ ηwh < 36 | 34 ≤ ηwh < 37 | 35 ≤ ηwh < 38 | 36 ≤ ηwh < 40

E | 22 ≤ ηwh < 26 | 23 ≤ ηwh < 26 | 26 ≤ ηwh < 29 | 26 ≤ ηwh < 29 | 30 ≤ ηwh < 33 | 30 ≤ ηwh < 34 | 30 ≤ ηwh < 35 | 32 ≤ ηwh < 36

F | 19 ≤ ηwh < 22 | 20 ≤ ηwh < 23 | 23 ≤ ηwh < 26 | 23 ≤ ηwh < 26 | 27 ≤ ηwh < 30 | 27 ≤ ηwh < 30 | 27 ≤ ηwh < 30 | 28 ≤ ηwh < 32

G | ηwh < 19 | ηwh < 20 | ηwh < 23 | ηwh < 23 | ηwh < 27 | ηwh < 27 | ηwh < 27 | ηwh < 28

The energy efficiency class of a solar hot water storage tank, if (part of) a solar device, shall be determined on the basis of its standing loss as set out in Table 4.

Energy efficiency class | Standing loss S in Watts, with storage volume V in litres

A+ | S5,5 3,16 V0,4

A | 5,5 3,16 V0,4S8,5 4,25 V0,4

B | 8,5 4,25 V0,4S12 5,93 V0,4

C | 12 5,93 V0,4S16,66 8,33 V0,4

D | 16,66 8,33 V0,4S21 10,33 V0,4

E | 21 10,33 V0,4S26 13,66 V0,4

F | 26 13,66 V0,4S31 16,66 V0,4

G | S31 16,66 V0,4