A.ComputerA device which performs logical operations and processes data. Computers are composed of, at a minimum: (1) a central processing unit (CPU) to perform operations; (2) user input devices such as a keyboard, mouse, digitizer or game controller; and (3) a computer display screen to output information. For the purposes of this specification, computers include both stationary and portable units, including desktop computers, integrated desktop computers, notebook computers, small-scale servers, thin clients and workstations. Although computers must be capable of using input devices and computer displays, as noted in numbers 2 and 3 above, computer systems do not need to include these devices on shipment to meet this definition.
B.Computer DisplayA display screen and its associated electronics encased in a single housing, or within the computer housing (e.g., notebook or integrated desktop computer), that is capable of displaying output information from a computer via one or more inputs, such as a VGA, DVI, Display Port, and/or IEEE 1394. Examples of computer display technologies are the cathode-ray tube (CRT) and liquid crystal display (LCD).
C.Discrete Graphics Processing Unit (GPU)A graphics processor with a local memory controller interface and a local, graphics-specific memory.
D.External Power SupplyA component contained in a separate physical enclosure external to the computer casing and designed to convert line voltage AC input from the mains to lower DC voltage(s) for the purpose of powering the computer. An external power supply must connect to the computer via a removable or hard-wired male/female electrical connection, cable, cord or other wiring.
E.Internal Power SupplyA component internal to the computer casing and designed to convert AC voltage from the mains to DC voltage(s) for the purpose of powering the computer components. For the purposes of this specification, an internal power supply must be contained within the computer casing but be separate from the main computer board. The power supply must connect to the mains through a single cable with no intermediate circuitry between the power supply and the mains power. In addition, all power connections from the power supply to the computer components, with the exception of a DC connection to a computer display in an Integrated Desktop Computer, must be internal to the computer casing (i.e., no external cables running from the power supply to the computer or individual components). Internal DC-to-DC converters used to convert a single DC voltage from an external power supply into multiple voltages for use by the computer are not considered internal power supplies.
F.Desktop ComputerA computer where the main unit is intended to be located in a permanent location, often on a desk or on the floor. Desktops are not designed for portability and utilise an external computer display, keyboard, and mouse. Desktops are designed for a broad range of home and office applications.
G.Small-Scale Server
A computer that typically uses desktop components in a desktop form factor, but is designed primarily to be a storage host for other computers. A computer must have the following characteristics to be considered a Small-Scale Server:
Designed in a pedestal, tower, or other form factor similar to those of desktop computers such that all data processing, storage, and network interfacing is contained within one box/product;
Intended to be operational 24 hours/day and 7 days/week, and unscheduled downtime is extremely low (in the order of hours/year);
Capable of operating in a simultaneous multi-user environment serving several users through networked client units; and
Designed for an industry-accepted operating system for home or low-end server applications (e.g., Windows Home Server, Mac OS X Server, Linux, UNIX, Solaris).
Small-Scale Servers are designed to perform functions such as providing network infrastructure services (e.g., archiving) and hosting data/media. These products are not designed to process information for other systems or run web servers as a primary function.
This specification does not cover Computer Servers as defined in the ENERGY STAR Version 1.0 Computer Server specification. Small-Scale Servers covered by this specification are limited to computers marketed for non-datacentre operation (e.g. homes, small offices).
H.Integrated Desktop ComputerA desktop system in which the computer and computer display function as a single unit which receives its AC power through a single cable. Integrated desktop computers come in one of two possible forms: (1) a system where the computer display and computer are physically combined into a single unit; or (2) a system packaged as a single system where the computer display is separate but is connected to the main chassis by a DC power cord and both the computer and computer display are powered from a single power supply. As a subset of desktop computers, integrated desktop computers are typically designed to provide similar functionality as desktop systems.
Thin ClientAn independently-powered computer that relies on a connection to remote computing resources to obtain primary functionality. Main computing (e.g., programme execution, data storage, interaction with other Internet resources, etc.) takes place using the remote computing resources. Thin Clients covered by this specification are limited to devices with no rotational storage media integral to the computer. The main unit of a Thin Client covered by this specification must be intended for location in a permanent location (e.g. on a desk) and not for portability.
J.Notebook ComputerA computer designed specifically for portability and to be operated for extended periods of time either with or without a direct connection to an AC power source. Notebooks must utilise an integrated computer display and be capable of operation off an integrated battery or other portable power source. In addition, most notebooks use an external power supply and have an integrated keyboard and pointing device. Notebook computers are typically designed to provide similar functionality to desktops, including operation of software similar in functionality as that used in desktops. For the purposes of this specification, docking stations are considered accessories and therefore the performance levels associated with notebooks presented in Section 3, below, do not include them. Tablet PCs, which may use touch-sensitive screens along with or instead of other input devices, are considered Notebook Computers in this specification.
K.Workstation
A high-performance, single-user computer typically used for graphics, CAD, software development, financial and scientific applications among other compute-intensive tasks. To qualify as a workstation, a computer must:
Be marketed as a workstation;
Have a mean time between failures (MTBF) of at least 15000 hours based on either Bellcore TR-NWT-000332, issue 6, 12/97 or field collected data; and
Support error-correcting code (ECC) and/or buffered memory.
In addition, a workstation must meet three of the following six optional characteristics:
Have supplemental power support for high-end graphics (i.e., PCI-E 6-pin 12V supplemental power feed);
The system is wired for greater than x4 PCI-E on the motherboard in addition to the graphics slot(s) and/or PCI-X support;
Does not support Uniform Memory Access (UMA) graphics;
Includes five or more PCI, PCIe or PCI-X slots;
Capable of providing multi-processor support to two or more processors (must support physically separate processor packages/sockets, i.e., not met with support for a single multi-core processor); and/or
Be qualified by at least two Independent Software Vendor (ISV) product certifications; these certifications can be in process, but must be completed within 3 months of qualification.
L.Off ModeThe power consumption level in the lowest power mode which cannot be switched off (influenced) by the user and that may persist for an indefinite time when the appliance is connected to the main electricity supply and used in accordance with the manufacturer's instructions. For systems where ACPI standards are applicable, the Off Mode correlates to ACPI System Level S5 state.
M.Sleep ModeA low power state that the computer is capable of entering automatically after a period of inactivity or by manual selection. A computer with sleep capability can quickly "awake" in response to network connections or user interface devices with a latency of ≤ 5 seconds from initiation of wake event to the system becoming fully usable, including rendering of display. For systems where ACPI standards are applicable, the Sleep mode most commonly correlates to ACPI System Level S3 (suspend to RAM) state.
N.Idle StateThe state in which the operating system and other software have completed loading, a user profile has been created, the machine is not asleep, and activity is limited to those basic applications that the system starts by default.
O.Active StateThe state in which the computer is carrying out useful work in response to a) prior or concurrent user input or b) prior or concurrent instruction over the network. This state includes active processing, seeking data from storage, memory, or cache, including idle state time while awaiting further user input and before entering low power modes.
P.Typical Energy Consumption (TEC)A method of testing and comparing the energy performance of computers, which focuses on the typical electricity consumed by a product while in normal operation during a representative period of time. For Desktops and Notebooks, the key criterion of the TEC approach is a value for typical annual electricity use, measured in kilowatt-hours (kWh), using measurements of average operational mode power levels scaled by an assumed typical usage model (duty cycle). For Workstations, requirements are based on a TEC power value calculated from operational mode power levels, maximum power, and an assumed duty cycle.
Q.Network InterfaceThe components (hardware and software) whose primary function is to make the computer capable of communicating over one or more network technologies. Examples of Network Interfaces are IEEE 802.3 (Ethernet) and IEEE 802.11 (Wi-Fi).
R.Wake EventA user, scheduled, or external event or stimulus that causes the computer to transition from Sleep or Off to active mode of operation. Examples of wake events include, but are not limited to: movement of the mouse, keyboard activity, controller input, real-time clock event, or a button press on the chassis, and in the case of external events, stimulus conveyed via a remote control, network, modem, etc.
S.Wake On LAN (WOL)Functionality which allows a computer to wake from Sleep or Off when directed by a network request via Ethernet.
T.Full Network ConnectivityThe ability of the computer to maintain network presence while in sleep mode and intelligently wake when further processing is required (including occasional processing required to maintain network presence). Maintaining network presence may include obtaining and/or defending an assigned interface or network address, responding to requests from other nodes on the network, or maintaining existing network connections, all while in the sleep state. In this fashion, presence of the computer, its network services and applications, is maintained even though the computer is in sleep mode. From the vantage point of the network, a sleeping computer with full network connectivity is functionally equivalent to an idle computer with respect to common applications and usage models. Full network connectivity in sleep is not limited to a specific set of protocols but can cover applications installed after initial installation.
U.Enterprise ChannelsSales channels normally used by large and medium-sized business, government organisations, educational institutions, or other organisations purchasing computers used in managed client/server environments.
Model NumberA unique marketing name that applies to a specific hardware/software configuration (i.e. operating system, types or processors, memory, GPU, etc.) that is either pre-defined, or a configuration selected by the customer.
W.Model NameA marketing name that includes reference to both the PC model family number, a short description of the product, or branding references.
Product FamilyA high-level description referring to a group of computers typically sharing one chassis/motherboard combination that often contains hundreds of possible hardware and software configurations.
Computers must meet the computer definition and one of the product type definitions provided in Section 1, above, to qualify as ENERGY STAR. The following table provides a list of the types of computers that are (and are not) eligible for ENERGY STAR.
Products Covered by this Version 5.0 Specification | Products Not Covered by this Version 5.0 Specification
Desktop Computers
Integrated Desktop Computers
Notebook Computers
Workstations
Small-Scale Servers
Thin Clients
Computer Servers (as defined in Version 1.0 Computer Server specification)
Handhelds, PDAs, and Smartphones
Computers must meet the requirements below to qualify as ENERGY STAR. The Version 5.0 effective date is covered in Section 5 of this specification.
Computers must meet the requirements below to qualify as ENERGY STAR. The Version 5.0 effective date is covered in Section 5 of this specification.
Computers Using an Internal Power Supply: 85 % minimum efficiency at 50 % of rated output and 82 % minimum efficiency at 20 % and 100 % of rated output, with Power Factor ≥ 0.9 at 100 % of rated output.
Computers Using an External Power Supply: External Power Supplies sold with ENERGY STAR computers must be ENERGY STAR qualified or meet the no-load and active mode efficiency levels laid down in the ENERGY STAR Program Requirements for Single Voltage External AC-AC and AC-DC Power Supplies, Version 2.0. The ENERGY STAR specification and qualified product list can be found at www.energystar.gov/powersupplies. Note: This performance requirement also applies to multiple voltage output external power supplies as tested in accordance with the Internal Power Supply test method referenced in Section 4, below.
For the purposes of determining TEC levels, desktops and integrated desktops must qualify under Categories A, B, C, or D as defined below:
Category A: all desktop computers that do not meet the definition of Category B, Category C, or Category D below will be considered under Category A for ENERGY STAR qualification.
Category B: to qualify under Category B, desktops must have:
equal to two physical cores; and
two gigabytes (GB) of system memory.
Category C: To qualify under Category C, desktops must have:
greater than two physical cores.
In addition to the requirement above, models qualifying under Category C must be configured with at least one of the following two characteristics:
at least two gigabytes (GB) of System Memory, and/or
a discrete GPU
Category D: to qualify under Category D, desktops must have:
at least four physical cores
In addition to the requirement above, models qualifying under Category D must be configured with at least one of the following two characteristics:
at least four gigabytes (GB) of System Memory; and/or
a discrete GPU with a frame buffer width greater than 128-bit.
For the purposes of determining TEC levels, notebooks must qualify under Categories A, B, or C as defined below:
Category A: All notebook computers that do not meet the definition of Category B or Category C below will be considered under Category A for ENERGY STAR qualification.
Category B: To qualify under Category B, notebooks must have:
A discrete GPU
Category C: To qualify under Category C, notebooks must have:
greater than or equal to 2 physical cores;
greater than or equal to 2 gigabytes (GB) of system memory; and
a discrete GPU with a frame buffer width greater than 128-bit.
The following tables indicate the required TEC levels for the 5.0 Specification. Table 1 below lists TEC requirements for Version 5.0, while Table 2 gives weightings for each operational mode by product type. TEC will be determined using the formula below:
ETEC = 8760/1000 · Poff · Toff + Psleep · Tsleep + Pidle · Tidle, where all Px are power values in watts, all Tx are Time values in % of year, and the TEC ETEC is in units of kWh and represents annual energy consumption based on mode weightings in Table 2.
Desktops and Integrated Computers (kWh) | Notebook Computers (kWh)
TEC (kWh) | Category A: ≤ 148.0 | Category A: ≤ 40.0
Category B: ≤ 175.0 | Category B: ≤ 53.0
Category C: ≤ 209.0 | Category C: ≤ 88.5
Category D: ≤ 234.0 |
Capability Adjustments
Memory |
1 kWh (per GB over base)
Base Memory:
Categories A, B and C:
2GB
Category D:
4 GB
0.4 kWh (per GB over 4)
Premium Graphics (for Discrete GPUs with specified Frame Buffer Widths) |
Cat. A, B:
35 kWh (FB Width ≤ 128-bit)
50 kWh (FB Width > 128-bit)
Cat. C, D:
50 kWh (FB Width > 128-bit)
Cat. B:
3 kWh (FB Width > 64-bit)
Additional Internal Storage | 25 kWh | 3 kWh
Note: Proxying refers to a computer that maintains Full Network Connectivity as defined in Section 1 of this specification. For a system to qualify under the proxying weightings above, it must meet a non-proprietary proxying standard that has been approved by the EPA and the European Commission as meeting the goals of ENERGY STAR. Such approval must be in place prior to submittal of product data for qualification. See Section 3.C, "Qualifying Computers with Power Management Capabilities", for further information and testing requirements.
Desktop | Notebook
Conventional | Proxying* | Conventional | Proxying*
Toff | 55 % | 40 % | 60 % | 45 %
Tsleep | 5 % | 30 % | 10 % | 30 %
Tidle | 40 % | 30 % | 30 % | 25 %
The following tables indicate the required PTEC levels for the 5.0 Specification. Table 3 below lists PTEC requirements for Version 5.0, while Table 4 gives weightings for each operational mode. PTEC will be determined using the formula below:
PTEC = 0.35 · Poff + 0.10 · Psleep + 0.55 · Pidle
where all Px are power values in watts.
PTEC ≤ 0.28 · Pmax + # HDD · 5
Note: Weightings are included in the PTEC formula, above.
Toff | 35 %
Tsleep | 10 %
Tidle | 55 %
Workstations that meet ENERGY STAR requirements with a single graphics device may also qualify for a configuration with more than one graphics device, provided the additional hardware configuration is identical with the exception of the additional graphics device(s). The use of multiple graphics includes, but is not limited to, driving multiple displays and ganging for high-performance, multi-GPU configurations (e.g. ATI Crossfire, NVIDIA SLI). In such cases, and until such time as SPECviewperf® supports multiple graphics threads, manufacturers may submit the test data for the workstation with the single graphics device for both configurations without retesting the system.
For the purposes of determining Idle state levels, Small-Scale Servers must qualify under Categories A or B, as defined below:
Category A: All Small-Scale Servers that do not meet the definition of Category B will be considered under Category A for ENERGY STAR qualification.
Category B: To qualify under Category B Small-Scale Servers must have:
processor(s) with greater than 1 physical core or greater than 1 discrete processor; and
a minimum of 1 gigabyte of system memory
Small-Scale Server Operational Mode Power Requirements
Off Mode: ≤ 2.0 W
Idle State:
Category A: ≤ 50.0 W
Category B: ≤ 65.0 W
Capability | Additional Power Allowance
Wake On LAN (WOL)
(Applies only if computer is shipped with WOL enabled)
+ 0.7 W for Off
Thin Client Categories for Idle Criteria: For the purposes of determining Idle levels, Thin Clients must qualify under Categories A or B as defined below:
Category A: All Thin Clients that do not meet the definition of Category B, below, will be considered under Category A for ENERGY STAR qualification.
Category B: To qualify under Category B, Thin Clients must:
Support local multimedia encode/decode
Thin Client Operational Mode Power Requirements
Off Mode: ≤ 2 W
Sleep Mode (if applicable): ≤ 2 W
Idle State:
Category A: ≤ 12.0 W
Category B: ≤ 15.0 W
Capability | Additional Power Allowance
Wake On LAN (WOL)
(Applies only if computer is shipped with WOL enabled)
+ 0.7 W for Sleep
+ 0.7 W for Off
Products must meet the power management requirements detailed in Table 8, below, and be tested as shipped.
Specification Requirement | | Applicable to
Shipment Requirements
Sleep Mode | Shipped with a Sleep mode which is set to activate within 30 minutes of user inactivity. Computers shall reduce the speed of any active 1 Gb/s Ethernet network links when transitioning to Sleep or Off. | Desktop Computers | √
Integrated Desktop Computers | √
Notebook Computers | √
Workstations | √
Small-Scale Servers |
Thin Clients |
Display Sleep Mode | Shipped with the display's Sleep mode set to activate within 15 minutes of user inactivity. | Desktop Computers | √
Integrated Desktop Computers | √
Notebook Computers | √
Workstations | √
Small-Scale Servers (if computer display is present) | √
Thin Clients | √
Network Requirements for Power Management
Wake on LAN (WOL) | Computers with Ethernet capability shall have the ability to enable and disable WOL for Sleep mode. | Desktop Computers | √
Integrated Desktop Computers | √
Notebook Computers | √
Workstations | √
Small-Scale Servers | √
Thin Clients (Only applies if software updates from the centrally managed network are conducted while the unit is in sleep or off mode. Thin Clients whose standard framework for upgrading client software does not require off-hours scheduling are exempt from the requirement.) | √
Wake on LAN (WOL) |
Applies to computers shipped through Enterprise Channels, only:
Computers with Ethernet capability must meet one of the following requirements:
be shipped with Wake On LAN (WOL) enabled from the Sleep mode when operating on AC power (i.e. notebooks may automatically disable WOL when disconnected from the mains); or
provide control to enable WOL that is sufficiently-accessible from both the client operating system user interface and over the network if computer is shipped to enterprise without WOL enabled.
Desktop Computers | √
Integrated Desktop Computers | √
Notebook Computers | √
Workstations | √
Small-Scale Servers | √
Thin Clients (Only applies if software updates from the centrally managed network are conducted while the unit is in sleep or off mode. Thin Clients whose standard framework for upgrading client software does not require off-hours scheduling are exempt from the requirement.) | √
Wake Management |
Applies to computers shipped through Enterprise Channels, only: