Desktop, Integrated Desktop, Notebook Computers: Below is a sample TEC calculation intended to show how compliance levels are determined based on functional adders and operational mode measurements, for an example ETEC evaluation for a Category A Notebook Computer (integrated GPU, 8 GB Memory Installed, 1 HDD)
Measure values using the Appendix A test procedure:
Off = 1 W
Sleep = 1.7 W
Idle = 10 W
Determine which Capability Adjustments apply:
Integrated Graphics? Does not apply for Premium Graphics.
8GB Memory installed. Does meet memory adjustment level: 8 yields a 1.6 kWh adjustment (4 · 0.4 kWh).
Apply Weightings based on Table 2 to calculate TEC:
Table 2 (for conventional notebook):
Toff | 60 %
Tsleep | 10 %
Tidle | 30 %
ETEC = 8760/1000 · Poff · Toff + Psleep · Tsleep + Pidle · Tidle
= 8760/1000 · Poff · 0.60 + Psleep · 0.10 + Pidle · 0.30
= 8760/1000 · 1 · 0.60 + 1.7 · 0.10 + 10 · 0.30
= 33.03 kWh
Determine TEC Requirement for the computer by adding any capability adjustments (step 2) to the Base TEC requirement (Table1).
Table 1 (for notebooks):
Notebook Computers (kWh)
Category A | 40
Category B | 53
Category C | 88.5
ENERGY STAR TEC Requirement = 40 kWh + 1.6 kWh = 41.6 kWh
Compare ETEC to the ENERGY STAR TEC Requirement (step 4) to ascertain whether the model qualifies.
Category A TEC requirement: 41.6 kWh
ETEC: 33.03 kWh
33.03 kWh < 41.6 kWh
Notebook meets the ENERGY STAR requirements.
Workstations: Below is a sample PTEC calculation for a Workstation with two hard drives.
Measure values using the Appendix A test procedure.
Off = 2 W
Sleep = 4 W
Idle = 80 W
Max Power = 180 W
Note number of Hard Drives installed.
Two hard drives installed during test.
Apply Weightings based on Table 4 to calculate PTEC:
Table 4:
Toff | 35 %
Tsleep | 10 %
Tidle | 55 %
PTEC = 0.35 · Poff + 0.10 · Psleep + 0.55 · Pidle
= 0.35 · 2 + 0.10 · 4 + 0.55 · 80
= 45.10 W
Calculate the PTEC requirement using the formula in Table 3.
PTEC = 0.28 · Pmax + # HDD · 5
PTEC = 0.28 · 180 + 2 · 5
PTEC = 53.2
Compare the adjusted PTEC to the ENERGY STAR levels to determine if the model qualifies.
45.10 < 53.2
Workstation meets the ENERGY STAR requirements.