Schedule 3 MONITORING, The Water Supply (Water Quality) Regulations 2018

In forcesince 28 Mar 2019cited 1×

Part 1

Group A and Group B Parameters

Table 1

Group A parameters and circumstances for monitoring

1 Sampling for this parameter in water supply zones may be substituted by sampling at supply points.

Item number (1) | Parameter (2) | Circumstances (3)

1 | Aluminium | Where used as a water treatment chemical or where the water originates from, or is influenced by, surface waters

2 | Ammonium | Where chloramination is practised

3 | Coliform bacteria | In all circumstances

4 | Colony counts 22 ° C | In all circumstances

5 | Colour | In all circumstances

6 | Conductivity1 | In all circumstances

7 | E. coli | In all circumstances

8 | Hydrogen ion | In all circumstances

9 | Iron | Where used as a water treatment chemical or where the water originates from, or is influenced by, surface waters

10 | Manganese | Where the water originates from, or is influenced by, surface waters

11 | Nitrate | Where chloramination is practised

12 | Nitrite | Where chloramination is practised

13 | Odour | In all circumstances

14 | Residual disinfectant | In all circumstances

15 | Taste | In all circumstances

16 | Turbidity | In all circumstances

Note:

Table 2

Group B1 parameters and circumstances for monitoring to be used for sampling in water supply zones (or supply points)

1 Sampling for these parameters may be within water supply zones (Group B1) or at supply points (Group B2).

2 Monitoring of this parameter in water supply zones is required only where sodium hypochlorite is added after water has left the treatment works. In other circumstances, monitoring is required at supply points, see Group B2.

3 To monitor for indicative dose.

4 In the event that a single sample is taken in a year, a further sample must be taken if there is any change in relation to that supply that could affect the concentration of radionuclides in the water supply.

Item number | Parameter (2) | Circumstances

1 | Aluminium |

Where—

(i)

not used as a water treatment chemical; or

(ii)

the water neither originates from, nor is influenced by, surface waters.

2 | Ammonium | Where chloramination is not practised

3 | Antimony | In all circumstances

4 | Arsenic | In all circumstances

5 | Benzene 1 | In all circumstances

6 | Benzo(a)pyrene | In all circumstances

7 | Boron 1 | In all circumstances

8 | Bromate 2 | In all circumstances

9 | Cadmium | In all circumstances

10 | Chloride 1 | In all circumstances

11 | Chromium | In all circumstances

12 | Clostridium perfringens (including spores) | In all circumstances

13 | Copper | In all circumstances

14 | Cyanide 1 | In all circumstances

15 | 1, 2 dichloroethane 1 | In all circumstances

16 | Enterococci | In all circumstances

17 | Fluoride 1 | In all circumstances

18 | Gross alpha 134 | In all circumstances

19 | Gross beta 134 | In all circumstances

20 | Iron |

Where—

(i)

not used as a flocculant; or

(ii)

the water neither originates from, nor is influenced by, surface waters.

21 | Lead | In all circumstances

22 | Manganese | Where the water neither originates from, nor is influenced by, surface waters.

23 | Mercury 1 | In all circumstances

24 | Nickel | In all circumstances

25 | Nitrate | Where chloramination is not practised.

26 | Nitrite | Where chloramination is not practised.

27 | Pesticides and related products 1 | In all circumstances

28 | Polycyclic aromatic hydrocarbon | In all circumstances

29 | Radon 14 | In all circumstances

30 | Selenium | In all circumstances

31 | Sodium | In all circumstances

32 | Sulphate 1 | In all circumstances

33 | Tetrachloroethene 1 | In all circumstances

34 | Tetrachloromethane 1 | In all circumstances

Total organic carbon 1

35 | Trichloroethene | In all circumstances

Trihalomethanes: Total

36 | Tritium 14 | In all circumstances

Notes:

Table 3

Group B2 parameters and circumstances for monitoring to be used for sampling at works or in water supply zones (or supply points)

1 Sampling for these parameters may be within water supply zones (Group B1) or at supply points (Group B2).

2 Monitoring is required at supply points where sodium hypochlorite is not added after water has left the treatment works. In other circumstances, see Group B1.

3 To monitor for indicative dose.

4 In the event that a single sample is taken in a year, a further sample must be taken if there is any change in relation to that supply that could affect the concentration of radionuclides in the water supply.

Item number | Parameter 2 | Circumstances

1 | Benzene 1 | In all circumstances

2 | Boron 1 | In all circumstances

3 | Bromate 2 | In all circumstances

4 | Chloride 1 | In all circumstances

5 | Colstridium perfringens (including spores)(1) | In all circumstances

6 | Cyanide 1 | In all circumstances

7 | 1, 2 dichloroethane 1 | In all circumstances

8 | Fluoride 1 | In all circumstances

9 | Gross alpha 134 | In all circumstances

10 | Gross beta 134 | In all circumstances

11 | Indicative dose (1) | In all circumstances

12 | Mercury 1 | In all circumstances

13 | Nitrite | When chloramination is not practised.

14 | Pesticides and related products 1 | In all circumstances

15 | Radon 14 | In all circumstances

16 | Sulphate 1 | In all circumstances

17 | Tetrachloroethene/Trichloroethene(1) | In all circumstances

18 | Tetrachloromethane 1 | In all circumstances

19 | Total organic carbon 1

20 | … | …

21 | Tritium 14 | In all circumstances

Notes:

Table 4

Group A1 parameters

Item number | Parameter

1 | Coliform bacteria

2 | E. coli

3 | Residual disinfectant

Table 5

Group A2 parameters

Item number | Parameter

1 | Coliform bacteria

2 | Colony counts 22° C

3 | E.coli

4 | Nitrite

5 | Residual disinfectant

6 | Turbidity

Table 6

Group A3 parameters

Item number | Parameter

1 | Conductivity

Table 7

Group A4 parameters

Item number | Parameter

1 | Aluminium

2 | Ammonium

3 | Colony counts 22° C

4 | Colour

5 | Conductivity

6 | Hydrogen ion

7 | Iron

8 | Manganese

9 | Nitrate

10 | Nitrite

11 | Odour

12 | Taste

13 | Turbidity

PART 2

Annual sampling frequencies: water supply zones

Table 8

Annual sampling frequencies for Group A4 parameters: water supply zones

Note:

This table and each table which follows it in this Part set out the annual sampling frequencies for all the substances and parameters comprising each of the groups to which they correspond, those groups having been outlined in Part 1 of this Schedule. These are determined for each water supply zone according to its estimated population (as specified in column one of each table in this Part). The number of samples to be taken is the standard number specified in column 2, unless a notice varying this number has been given under regulation 9.

Estimated population of water supply zone | Standard sampling frequency per year

<100 | 2

100-4,999 | 4

5,000—9,999 | 12

10,000-29,999 | 24

30,000-49,999 | 36

50,000-79,999 | 52

80,000-100,000 | 76

Table 9

Annual sampling frequencies for Group B1 parameters: water supply zones

Estimated population of water supply zone | Standard sampling frequency per year

<100 | 1

100-4,999 | 4

5,000-100,000 | 8

Table 10

Annual sampling frequencies for Group A1: water supply zones

Estimated population of water supply zone | Standard sampling frequency per year

<100 | 4

≥100 | 12 per 5,000 population

Note:

For the purposes of this Table, where the population is not an exact multiple of 5,000, the population figure must be rounded up to the nearest multiple of 5,000.

PART 3

Annual sampling frequencies: treatment works and supply points

Table 11

Annual sampling frequencies for Group A2 parameters: treatment works or supply points

Note: This table and each table which follows it in this Part set out the annual sampling frequencies for all the substances and parameters comprising each of the groups to which they correspond at treatment works or supply points, those groups having been outlined in Part 1 of this Schedule. The frequencies are determined according to the volume of water supplied at each treatment works or supply point. The number of samples to be taken is the standard number specified in column 2, unless a notice varying this number has been issued under regulation 9.

Volume of water supplied m 3/day | Standard sampling frequency per year

<20 | 4

20-1,999 | 52

2,000-5,999 | 104

6,000-11,999 | 208

≥12,000 | 365

Table 12

Annual sampling frequencies for Group A3 parameters: treatment works or supply points

Volume of water supplied m 3/day | Standard sampling frequency per year

<20 | 2

20-999 | 4

1,000-1999 | 12

2,000-5,999 | 24

6,000-9,999 | 36

10,000-15,999 | 52

16,000-32,999 | 104

33,000-49,999 | 156

50,000-67,999 | 208

68,000-84,999 | 260

85,000-101,999 | 312

102,000-119,999 | 365

120,000-241,999 | 730

242,000-484,999 | 1,460

485,000-728,999 | 2,190

Table 13

Annual sampling frequencies for Group B2 parameters: treatment works or supply points

Volume of water supplied m 3/day | Standard sampling frequency per year

<20 | 1

20-999 | 4

1,000-49,999 | 8

50,000-89,999 | 12

90,000-299,999 | 24

300,000-649,999 | 36

≥650,000 | 48