In addition to the definitions of Article 3 of Regulation (EC) No 396/2005, the following definitions apply for the purposes of this Regulation:
‘lot’ means an identifiable quantity of food and feed delivered at one time and determined by the sampling officer to have common characteristics (such as origin, producer, variety, species, catch area, packer, type of packing, markings, hour of production or consignor);
‘sublot’ means a part of a lot that is designated to be sampled in accordance with section B.1 of the Annex;
‘suspect lot’ means a lot which, for any reason, is suspected to contain pesticide residues exceeding the respective MRLs set out in Regulation (EC) No 396/2005;
‘non-suspect lot’ means a lot for which there is no indication that it may contain pesticide residues exceeding MRLs set out in Regulation (EC) No 396/2005;
‘sampling’ means the selection of a sample intended for laboratory analysis;
‘sampling officer’ means a person designated by the competent authorities to take samples for purposes of control of pesticide residues of food and feed;
‘sample’ means one or more units selected from a population of units, or a portion of material selected from a larger quantity of material;
‘incremental (primary) sample’ means a quantity of material taken from a specific place in the lot or sublot;
‘unit’ means the smallest distinct portion in a lot or sublot, withdrawn to form the whole or part of an incremental sample;
‘aggregate sample’ means the combined total of all the incremental samples taken from the lot or sublots;
‘reduced sample’ is a part of the aggregate sample, obtained from the latter by a process of representative reduction;
‘replicate sample’ means a sample taken from an aggregate sample for enforcement, defence and reference purposes in accordance with Article 35 of Regulation (EU) 2017/625;
‘laboratory sample’ means a sample sent to, or received by, the laboratory that constitutes a representative quantity of material removed from the aggregate sample;
‘analytical sample’ means material prepared for analysis from the laboratory sample;
‘analytical portion’ means a representative quantity of material removed from the analytical sample, of proper size for measurement of the residue concentration;
‘measurement uncertainty’ means a non-negative parameter associated with the result of measurement, which characterises the dispersion of values that could reasonably be attributed to the particular quantity subject to measurement;
‘limit of quantification’ means the lowest concentration or mass of the analyte that has been validated with acceptable accuracy by applying the complete analytical method and identification criteria;
‘expanded measurement uncertainty’ represents the uncertainty in a measurement by giving a confidence range, typically calculated by multiplying the range of values within which the true value of the measurement is expected to lie by a coverage factor;
‘coverage factor (k)’ is a multiplier used in the calculation of expanded measurement uncertainty, which provides a range within which the true value of a measurement is expected to lie.